ABB - Installation Products K656LR-J0240-S - 15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded 1/0 or Compact/Solid 2/0. Cold-Shrinkable Jacket Seal Included.

ABB Installation Products K656LR-J0240-S 15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud…

UPC: 075114241281


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656LR-J0240-S is a 15/25kV 600 Amp Series Deadbreak Elbow with Test Point, engineered for reliable medium-voltage cable terminations in industrial and utility applications. This deadbreak elbow features a fully shielded, dead-front submersible design with a non-corrosive capacitive test point, enabling safe load-break operations and maintenance without de-energizing the system. The unit includes an aluminum compression lug compatible with 1/0 or compact/solid 2/0 conductors, supporting cable insulation diameters between 0.980 inch and 1.180 inch. The cold-shrinkable jacket seal enhances environmental resistance, preventing moisture ingress and contamination in underground distribution systems, switchgear connections, and pad-mounted transformers. The 100% peroxide-cured EPDM construction ensures long-term mechanical and electrical integrity, with a continuous current rating of 600 Amps and impulse withstand of 95kV BIL for 15kV class operations. The elbow connector housing is fully rated to ANSI/IEEE Standard 386, providing a secure termination for high-voltage apparatus. Optional accessories enable visible external separation, bypass, isolation, dead-ending, grounding, and testing, making it ideal for renewable energy, utility, and industrial power distribution systems.
  • 15/25kV voltage class with 600 Amp continuous current rating
  • Fully shielded, dead-front submersible design for underground applications
  • Non-corrosive capacitive test point for safe load-break operations
  • Aluminum compression lug compatible with 1/0 or compact/solid 2/0 conductors
  • Cold-shrinkable jacket seal included for environmental resistance

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amp Deadbreak Elbow Connection
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Can be Easily Connected or Disconnected using Standard Hand Tools and Equipment in a De-Energized State. Non-Corrosive, Capacitive Test Point. Cold-Shrinkable Jacket Seal Included
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
7.5300 L
Package Weight (Metric)
3.4160 kg
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.

K655LR-H0240

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Copper Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed/Stranded 3/0 or Compact/Solid 4/0 or mm2 Compact 95.

K656LR-H2260

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Copper Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed/Stranded 3/0 or Compact/Solid 4/0 or mm2 Compact 95.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size Compressed/Stranded 1250. Cold-Shrinkable Jacket Seal Included.

K656LR-P0440-S

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size Compressed/Stranded 1250. Cold-Shrinkable Jacket Seal Included.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 700/750 or Compact/Solid 900. Cold Shrinkable Jacket Seal Included.

K656LRL5380S

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 700/750 or Compact/Solid 900. Cold Shrinkable Jacket Seal Included.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Copper Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. Cold-Shrinkable Seal with Copper Braid and Constant Force Spring

K656LR-K2300-SG3

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Copper Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. Cold-Shrinkable Seal with Copper Braid and Constant Force Spring
600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, 600 Amp, Dead Break, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Compression Lug. Conductor Size AWG Compressed/Stranded 2/0 or Solid/Compact 3/0 or mm2 70.

K655LR-F2250

600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, 600 Amp, Dead Break, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Compression Lug. Conductor Size AWG Compressed/Stranded 2/0 or Solid/Compact 3/0 or mm2 70.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 350 or Compact/Solid 400. Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

K656LR-L5300-SG3

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 350 or Compact/Solid 400. Cold Shrinkable Seal with Copper Braid and Constant Force Spring.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded 1/0 or Compact/Solid 2/0. Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

K656LR-J5240-SG3

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded 1/0 or Compact/Solid 2/0. Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

Frequently Asked Questions

What is the maximum operating voltage for the K656LR elbow connector?

For the 15kV voltage class, the maximum operating voltage is 8.3kV phase-to-ground. For the 28kV voltage class, it is 16.2kV phase-to-ground.

What conductor sizes are compatible with the K656LR connector?

The K656LR is compatible with conductor ranges from #2 AWG to 1250 kcmil for both aluminum and copper conductors.

What is the continuous current rating for this deadbreak elbow?

The K656LR elbow connector has a continuous current rating of 600 Amps.

What insulation diameters does the K656LR accommodate?

The connector accommodates insulation diameters ranging from 0.640 inches to 1.935 inches.

Is a grounding device recommended for specific cable types?

Yes, when used on metallic tape shield or drain wire cable, an ECS cable seal grounding device is highly recommended for safety.

What standards does the K656LR meet?

The K656LR meets ANSI/IEEE Standard 386, Latest Revision.

What is the impulse withstand rating for the 28kV voltage class?

The impulse withstand rating for the 28kV voltage class is 140kV BIL for a 1.2 x 50 microsecond wave.

What is the AC one-minute withstand for the 15kV voltage class?

The AC one-minute withstand for the 15kV voltage class is 34kV.

What is the corona extinction level for the 28kV voltage class?

The corona extinction level for the 28kV voltage class is 21.5kV AC at 3pC sensitivity.

What is the momentary current rating for the K656LR?

The momentary current rating is 25kA Sym for 10 Cycles.

How to Install K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and connection of K655/K675LR Deadbreak Elbow Connectors on 15kV and 25kV class systems. It covers cable preparation, connector assembly, and initial setup.

Estimated time: 1h 30m

Tools needed:

Hotstick, Wire brush, Crimping tool, Wire strippers, Suitable sensing device (for capacitive test points), Suitable connector tool (for grounding wire)

Supplies needed:

Lubricant, Cable adapter, Compression lug, Insulating plug (optional), Threaded stud (optional), No. 14 AWG Copper wire (or equivalent), Silicone lubricant, Tape marker

  1. Prepare for Installation and Ensure Safety

    De-energize all apparatus in the work area before beginning installation. Inspect all package contents and components for damage and compatibility. Ensure all required tools are at hand and maintain cleanliness throughout the procedure.

  2. Prepare the Cable

    Assemble the cable in its final position with enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. Clean the outer surface of the cable for 24” (610mm) or up to the bent back concentric neutral wires.

  3. Perform Cable Preparation Specifics

    Prepare the cable according to its type (e.g., jacketed, non-jacketed, Unishield, lead sheath). Remove the outer jacket (if applicable) and prepare the cable insulation, semi-con shield, and other layers to the specified dimensions (e.g., 9-3/4”, 10-3/4”, 12-3/4” from the cable end). Refer to specific instructions for grounding devices or shield adapters if used.

  4. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  5. Prepare Conductor and Install Compression Lug

    Remove protruding cable insulation, cutting it even with the cable adapter end, ensuring no nicks to the adapter or conductor. The exposed conductor length must be 4-1/4” to 4-9/16” (108mm-116mm). For copper conductors, fully insert the conductor into the compression lug. For aluminum, wire brush and immediately insert. Crimp the lug according to its instructions, ensuring the 'Check Dimension' is less than 6-3/8” before crimping and the final distance from lug end to cable adapter is 6-3/8” to 7-1/8” (162mm-181mm). Wipe off excess inhibitor.

  6. Install the Elbow

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Verify the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  7. Prepare and Connect Mating Products

    WARNING: Do not connect or disconnect mating products while energized, and do not energize while disconnected. Remove protective caps from the elbow and the mating part. If the mating part lacks a stud, hand tighten the supplied threaded stud into it. Clean and lubricate both the elbow and the mating part. Push the elbow onto the mating part, aligning the compression lug hole with the stud.

  8. Secure Mating Part and Install Insulating Plug (if applicable)

    Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow, engage threads, and hand tighten. Torque the mating part as per its instructions. If using an insulating plug, clean and lubricate the inner surface of its voltage detection cap, then place it on the elbow, pushing until it snaps into place.

  9. Ground the Cable Shield

    Insert one end of a No. 14 AWG Copper wire (or equivalent) through the grounding eye, twist to form a small loop, and connect it to ground using a suitable connector. Ensure the cable shield is grounded, either via a grounding device or an alternate method. Waterproof the cable jacket at this point to prevent moisture ingress.

  10. Perform Voltage Test

    Remove the test point cap using a hotstick, peeling it off at an angle. WARNING: This is a capacitance device; do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means to prevent serious injury. After testing, clean and lubricate the inside of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.