ABB - Installation Products K656I-G2220 - 25KV 600 Amp, Deadbreak, Separable Straight Joint Package (2-Way) with Test Point, Cable Insulation Diameter .760-.950 inches, Copper Lug, Conductor Size #2 Stranded/Compressed or #1 Solid/Compact AWG. No Sealing kit.

ABB Installation Products K656I-G2220 25KV 600 Amp, Deadbreak, Separable Straight Joint Package (2-Way) with Test Point, Cable…

UPC: 075114260619


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Installation Products K656I-G2220 is a 25kV, 600 Amp deadbreak separable straight joint package designed for reliable medium-voltage cable connections in industrial and utility applications. This 2-way joint accommodates copper lugs and supports conductor sizes from #2 stranded/compressed to #1 solid/compact AWG, with cable insulation diameters ranging from 0.760 to 0.950 inches. The integrated test point enables safe voltage verification without cable disconnection, improving maintenance efficiency in tight spaces like vaults and manholes. This package is part of ABB’s deadbreak separable connector system, ensuring compatibility with standard medium-voltage cable accessories. The straight joint design simplifies installation in compact environments while maintaining electrical integrity. The fully shielded, fully submersible construction uses 100% peroxide-cured EPDM molded rubber for durability in direct-buried or submerged applications. Key ratings include: - 16.2kV max phase-to-ground and 28kV max phase-to-phase operating voltage for 25kV class systems - 140kV BIL impulse withstand (1.2 x 50 microsecond wave) - 45kV AC one-minute withstand and 84kV DC 15-minute withstand - 21kV AC corona extinction at 3pC sensitivity - 600 Amp continuous current with 25kA symmetrical momentary rating (10 cycles) The modular design allows for future system expansions or circuit changes, making it ideal for power distribution systems, substations, and industrial facilities requiring medium-voltage cable splicing. Reusable components reduce inventory and operational costs while maintaining long-term reliability in demanding environments.
  • 25kV class, 600 Amp continuous current rating
  • Supports #2 stranded/compressed or #1 solid/compact AWG conductors
  • Cable insulation diameter range: 0.760–0.950 inches
  • Integrated capacitive test point for safe voltage verification
  • Fully shielded, submersible design with 100% peroxide-cured EPDM rubber

Specifications

Amperage Rating
600 A
Application
Compact Design is suitable for small vaults and manholes
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Connection Type
Deadbreak Separable Straight Joint
Current Rating
600 A
Environmental Conditions
All Weather Conditions
Insulation
True
Length
37.27 in
Length
946.658 mm
Material
Housing - EPDM-Rubber
Material
Copper
Poles
2-Way
Series
K656I
Special Features
Fully Shielded, Fully Submersible, 100 percent Peroxide cured Molded EODM Rubber
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Seperable Straight Joint
Voltage Rating
25kV
Voltage Rating
15 to 25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit

168FLR1-B5220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
900 Amp, 15/25kV, 600 Series Straight Receptacle with Cable Adapter, Lug and Retaining Ring, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size kcmil Compressed Stranded 1000

K675SR-L2410

900 Amp, 15/25kV, 600 Series Straight Receptacle with Cable Adapter, Lug and Retaining Ring, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size kcmil Compressed Stranded 1000
900 Amp, 15/25kV, 600 Series Straight Receptacle with Cable Adapter, Lug and Retaining Ring, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0/Compacted Solid 250. Cold Shrinkable Seal included.

K675SR-H2270-S

900 Amp, 15/25kV, 600 Series Straight Receptacle with Cable Adapter, Lug and Retaining Ring, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0/Compacted Solid 250. Cold Shrinkable Seal included.
600 Amp, 15/25KV, Separable Straight Joint package 2-Way, with Test Point, Connector Kit, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.

K656ILM0380-K0300

600 Amp, 15/25KV, Separable Straight Joint package 2-Way, with Test Point, Connector Kit, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.
600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation Diameter .760 inch to .950 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 or Compacted Solid 3/0.

K656YSR-G0250

600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation Diameter .760 inch to .950 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 or Compacted Solid 3/0.
15kV, Straight Receptacle with Test Point and with Sealing Kit. Cable Insulation Diameter .575 to .740 inches, Aluminum Lug, Conductor Size code 220 is for #2 Stranded/Compressed or #1 Compact/Solid.

K152SR-A0220-S

15kV, Straight Receptacle with Test Point and with Sealing Kit. Cable Insulation Diameter .575 to .740 inches, Aluminum Lug, Conductor Size code 220 is for #2 Stranded/Compressed or #1 Compact/Solid.
25kV, 200 Amp, DeadBreak Straight Receptacle with Test Point, Cable Insulation Diameter .635-.905 inches, Aluminum Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid.

K152SR-B0240

25kV, 200 Amp, DeadBreak Straight Receptacle with Test Point, Cable Insulation Diameter .635-.905 inches, Aluminum Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid.
15/25kV, 600 Amp, Straight Receptacle, Deadbreak, Separable Cable Joint, includes Straight Receptacle Housing, Retaining Ring, Cable Adapter, Lug, Bolt and Washers, Cable Insulation Diameter .635-.905 inches, Aluminum Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid. With Sealing Kit.

K655YSR-L0240-S

15/25kV, 600 Amp, Straight Receptacle, Deadbreak, Separable Cable Joint, includes Straight Receptacle Housing, Retaining Ring, Cable Adapter, Lug, Bolt and Washers, Cable Insulation Diameter .635-.905 inches, Aluminum Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid. With Sealing Kit.

Frequently Asked Questions

What components are included in a complete K656I joint package?

A complete package includes an insulated bus bar, straight receptacle housing, retaining rings, cable size adapters, lugs, bolts, and washers.

Are the components of the K656I reusable?

Yes, the components of the K656I are reusable, which helps reduce inventory and other costs.

What material is the K656I joint made from?

The K656I joint is made from 100% peroxide cured EPDM molded rubber.

Does the K656I joint have a test point?

Yes, the K656I joint includes an integral capacitive test point.

What are the operating voltage limits for 25kV class?

For the 25kV class, the maximum phase-to-ground operating voltage is 16.2kV and phase-to-phase is 28kV.

What is the K656I joint used for?

The K656I joint is used to join cables in a disconnectable 2-way joint. It is suitable for small vaults, manholes, and direct-buried applications.

What is the impulse withstand rating for 25kV?

For the 25kV voltage class, the impulse withstand (BIL) is 140kV.

What standard does the K656I joint meet?

The K656I joint meets ANSI/IEEE Standard 386, Latest Revision.

What is the continuous current rating of the joint?

The continuous current rating for both 15kV and 25kV voltage classes is 600 Amp.

What are the operating voltage limits for 15kV class?

For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV and phase-to-phase is 14.4kV.

How to Install K656 Deadbreak Receptacles

This guide provides step-by-step instructions for the safe and proper installation of one leg of K656CY, K656CH, or K656I Deadbreak Receptacles, designed for splicing and tapping solid dielectric cables rated for 600A at 15kV and 25kV.

Estimated time: 1h 30m

Tools needed:

Hex wrench, Torque wrench with 15/16 inch socket, Wire brush (for aluminum cable), Assembly tool (650ATY or 600RRT), Rag, Approved safety solvent

Supplies needed:

Receptacle housings, Cable adapters, Center section (I, Wye, or H), Aluminum holding collars, Lubricant (supplied or ELASTIMOLD approved), Hex-head bolts, Crimp connectors, Belleville washers, Flat washers, Nylon venting rod, No. 14 AWG copper wire (for grounding), Tape (for markers and support)

  1. Prepare for Installation and Inspect Components

    DANGER: Ensure all apparatus is de-energized before starting. Inspect all receptacle components for damage, correct rating, and compatibility with mating parts. Confirm all package contents are complete and undamaged, and check threads for proper fit.

  2. Clean Cable Jacket and Position Housing

    Wipe the outer cable jacket clean for a distance of 38 inches (96.5 cm) from the end. Cut the cable end squarely. If using an ECS grounding device, slide its tube onto the cable 38 inches. Then, slide the receptacle housing onto the cable 30 inches (76.2 cm).

  3. Prepare Cable End (Type-Specific)

    Refer to the special cable preparation supplement (Part A for Jacketed Concentric Neutral or Part B for Flat Metallic Tape Shielded) for specific instructions. This involves removing the outer jacket and semi-con shield to specified lengths, creating a tape marker, beveling the insulation, and thoroughly cleaning the insulation. Lubricate the cable and the inside of the cable adapter, then slide the adapter onto the cable until flush with the tape marker.

  4. Trim Insulation and Assemble Retaining Ring

    Remove any protruding cable insulation, cutting it even with the end of the cable adapter. Ensure the exposed conductor measures 4 3/4 to 5 inches (12.1-12.7 cm). Assemble the aluminum retaining ring over the conductor, snug it firmly against the cable adapter, and hand-tighten the socket head screw. Confirm the exposed conductor now measures 4 3/8 to 4 3/4 inches (11.1-12.1 cm).

  5. Install and Crimp Connector

    Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor immediately before fully inserting it into the crimp connector. Confirm bolt holes align with the mating part. Crimp the connector following the provided instructions, rotating each crimp 90 or 180 degrees. Verify the distance from the end of the connector to the holding collar is 6 3/4 to 7 inches (17.1-17.8 cm).

  6. Assemble and Torque Splice Bolts

    Assemble the washers and bolt: flat washer against the spade contact, then the Belleville washer (concave side down), followed by the hex-head bolt. Hand tighten. Using a torque wrench with a 15/16 inch socket, tighten all bolts to 50 to 60 ft. lbs. Do not move or reposition any part after tightening.

  7. Lubricate and Position Receptacle Housing

    Apply the supplied or ELASTIMOLD approved lubricant generously to the outside of the cable adapter, the splice section, and the inside mating surface of the receptacle housing. Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the nylon venting rod.

  8. Engage Receptacle Housing with Assembly Tool

    Attach either the 650ATY or 600RRT assembly tool. Use the tool to slowly slide the receptacle housing completely over the splice section. Once fully engaged, remove the nylon venting rod. WARNING: Do not place hands on the threaded rod or guide shaft if using the 600RRT tool.

  9. Complete Grounding

    If an ECS grounding device is used, complete its installation according to its specific instructions. Connect a short length of No. 14 AWG copper wire (or equivalent) to the grounding eyes of the housings. Make a small loop and twist tightly, taking care not to damage the eye, and connect to ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.