Authorized ABB Distributor (Installation Products)
ABB - Installation Products K655SR-L-0360 - 600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 650 or Compacted Solid 750 or mmSquared Compact 400.

ABB Installation Products K655SR-L-0360 600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and…

UPC: 783786585601


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K655SR-L-0360 is a 600 Amp deadbreak straight receptacle designed for 15/25kV applications. This unit features a robust cable adapter, an aluminum compression lug, and a retaining ring for secure connections. Engineered for reliable performance in electrical distribution systems, this receptacle is suitable for cable insulation diameters ranging from 1.180 inches to 1.465 inches. The included aluminum compression lug is compatible with conductor sizes of 650 kcmil compressed stranded, 750 kcmil compacted solid, or 400 mm² compact conductors. The 600 Series deadbreak design ensures safe and efficient termination of high-voltage cables. This product, manufactured by ABB Installation Products, offers a dependable solution for utility and industrial power infrastructure. Its construction prioritizes secure cable management and electrical integrity, making it a vital component for maintaining operational continuity in demanding electrical environments. The K655SR-L-0360 is a critical piece of equipment for power distribution networks requiring high amperage and voltage handling capabilities.
  • 600 Amp current rating
  • 15/25kV voltage class
  • Deadbreak straight receptacle design
  • Includes cable adapter, aluminum compression lug, and retaining ring
  • Compatible with cable insulation diameters from 1.180" to 1.465"

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amps
Color
Black
Conductor Range
650 kcmil , 750 to 800 kcmil
Connection
Compression
Environmental Conditions
All Weather Conditions, Fully Submersible
Insulation
True
Length
16.98 in
Length
431.292 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle
Voltage Rating
15 to 25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15/25kV 600 Series Deadbreak 3-Way L-Kit, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.

K655L3-LM0360

15/25kV 600 Series Deadbreak 3-Way L-Kit, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 900 or Compacted Solid 1000 or mmSquared Compact 500.

K655SR-P-0400

600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 900 or Compacted Solid 1000 or mmSquared Compact 500.
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

K655SR-H-0330

600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
600 Amp, 15/25KV, Separable Straight Joint Package 2-Way with Test Point, Splice, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. Cold-Shrinkable Jacket Seal Included.

K656IK0320SG3G0240S

600 Amp, 15/25KV, Separable Straight Joint Package 2-Way with Test Point, Splice, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. Cold-Shrinkable Jacket Seal Included.
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded #2 or Compacted/Solid #1

K656CY-G0220

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded #2 or Compacted/Solid #1
600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point. N0360 - Cable Insulation Diameter 1.515 inch to 1.780 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 650 or Compacted/Solid 750. N0360 - Cable Insulation Diameter 1.515 inch to 1.780 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 650 or Compacted/Solid 750. K0260 - Cable Insulation Diameter 1.090 inch to 1.310 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 3/0 or Compacted/Solid 4/0.

K656CY-DP0591394

600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point. N0360 - Cable Insulation Diameter 1.515 inch to 1.780 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 650 or Compacted/Solid 750. N0360 - Cable Insulation Diameter 1.515 inch to 1.780 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 650 or Compacted/Solid 750. K0260 - Cable Insulation Diameter 1.090 inch to 1.310 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 3/0 or Compacted/Solid 4/0.
600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

K656CY-N0410

600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.

K656CY-K0300

600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.

Frequently Asked Questions

What is the maximum cable insulation diameter supported?

The receptacle supports cable insulation diameters ranging from 1.180 inches to 1.465 inches.

What conductor sizes are compatible with the lug?

The aluminum compression lug is compatible with 650 kcmil compressed stranded, 750 kcmil compacted solid, or 400 mm² compact conductors.

What is the voltage rating of this receptacle?

This receptacle is rated for 15/25kV applications.

What type of lug is included with this receptacle?

An aluminum compression lug is included with this receptacle.

How to Install the K655SR/M655SR Deadbreak Straight Receptacle

This guide provides step-by-step instructions for the safe and proper installation of the K655SR and M655SR Deadbreak Straight Receptacle, connecting an in-line cable to an ANSI-386 600 amp bushing.

Estimated time: 2h

Tools needed:

5/8-11 tap, Torque wrench, 15/16 socket, Hex wrench, Wire brush, Wire strippers, Crimp tool, Suitable connector crimping tool

Supplies needed:

Receptacle housing, Bushing adapter, Cable adapter, Aluminum holding collar, Hex head bolt, Crimp connector, Belleville washer, Flat washer, Nylon venting rod, Lubricants (supplied or ELASTIMOLD approved), Brass bolt, Bushing converter contact, Loctite, Tape marker, No. 14 AWG copper wire, Suitable connector (for neutral wires), Hose Clamp (for M655SR 35kV only)

  1. Prepare the Apparatus Bushing

    DANGER: All apparatus must be de-energized during installation. If a stud is present in the apparatus bushing, remove it and re-tap the hole using a 5/8-11 tap. Clean and lubricate the apparatus bushing and bushing converter interface. Apply 3-4 drops of Loctite to the brass bolt threads. Assemble the bushing converter onto the apparatus bushing. Attach the contact adapter to the apparatus bushing with the bolt hole facing out, using the 5/8” brass bolt. Torque the brass bolt to 60 ft.-lbs.

  2. Prepare the Cable End

    Train the cable end and straighten it into its final position. Cut the cable squarely to ensure maximum available length for crimp growth. If applicable, unwrap the concentric neutral wires a distance of 30” (76cm), then bend and fold them back out of the way without cutting.

  3. Clean the Cable Jacket and Slide Receptacle Housing

    Wipe the outer jacket clean for a distance of 38” (96.5cm) or up to the concentric neutral wires. Slide the receptacle housing onto the cable a distance of 30” (76cm).

  4. Prepare Cable Insulation and Install Cable Adapter

    Remove the semi-con shield and install a tape marker to the dimensions shown (10-1/4” (26.04cm) for semi-con, 11-1/4” (28.58cm) for tape marker). Do not cut or nick the cable insulation. Bevel the end of the cable insulation at a 45˚ angle, approximately 1/4” (6mm) back. Thoroughly clean and lubricate the cable insulation, working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  5. Expose Conductor and Position Holding Collar

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. Verify the exposed conductor length is 4 3/4” – 5” (12.06cm – 12.7cm); if not, redo the assembly. Position the holding collar over the conductor, flush against the cable adapter. Using the supplied hex wrench, tighten the setscrew.

  6. Prepare and Crimp the Connector

    Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor and immediately insert it into the crimp connector, ensuring full insertion. Measure the distance from the end of the connector to the holding collar; if over 7” (17.8cm), redo previous work. Confirm components are oriented correctly (Receptacle Housing, Cable Adapter, Crimp Connector, Contact Adapter). Align the bolt hole in the crimp connector with the bolt hole in the contact adapter. Crimp the connectors, rotating each crimp 90˚. After crimping, re-measure the distance; if over 7” (17.8cm), redo previous work.

  7. Assemble and Torque the Bolt

    Assemble the washers and bolt: Flat washer against spade contact, Belleville washer (concave side down), then the hex-head bolt. Hand tighten. Using a torque wrench with a 15/16 socket, tighten to 50-60 ft.-lbs. DANGER: Do not attempt to move or reposition any part of the assembly after the bolts are tightened.

  8. Lubricate and Seat Receptacle Housing

    Generously apply supplied or ELASTIMOLD approved lubricant to the outside of the cable adapter and bushing adapter area. WARNING: Do not substitute lubricants. Slide the receptacle housing over the cable adapter and up to the interface edge. Insert the supplied nylon venting rod. Slide the receptacle housing onto the bushing converter until fully seated. Remove the venting rod.

  9. Ground the Receptacle and Connect Neutrals

    Connect a short piece of No. 14 AWG copper wire (or equivalent) to the receptacle housing's grounding eye, forming a small loop and twisting tightly without damage. Gather the concentric neutral wires. Using a suitable connector, connect the neutral wires and the grounding wire.

  10. Install Hose Clamp (35kV Only)

    For 35kV installations only, position the hose clamp between the locator bumps on the receptacle housing. Tighten the clamp until an audible click is heard.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.