ABB - Installation Products K655LR-LM0330 - 600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.280 inch to 1.430 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.

ABB Installation Products K655LR-LM0330 600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and…

UPC: 783786527632


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB K655LR-LM0330 is a 600 Amp, 15/25kV deadbreak elbow connector engineered for medium-voltage cable systems, specifically designed for reliable, high-current terminations in underground distribution, switchgear, and transformer applications. This 600 Series component features a fully insulated plug, compression lug, stud, cap, and cable adapter, ensuring a secure and long-lasting connection for aluminum conductors. The deadbreak design enables safe, load-break operations under energized conditions, minimizing downtime during maintenance or reconfiguration without de-energizing the system. The unit accommodates cable insulation diameters ranging from 1.280 to 1.430 inches, providing compatibility with a wide range of medium-voltage cables. It supports conductor sizes of 500 kcmil (compressed or stranded) or 600 kcmil (compact or solid), as well as 250 or 300 mm² compact conductors, offering flexibility for various installation requirements. The aluminum compression lug delivers superior conductivity and corrosion resistance, enhancing the connector’s durability and performance in demanding environments. Designed to meet stringent electrical and mechanical performance standards, the K655LR-LM0330 is compatible with industry-standard 600 Series interfaces, ensuring seamless integration with existing medium-voltage systems. Its robust construction and compliance with applicable industry specifications make it a dependable solution for utility, industrial, and commercial installations where reliable, high-current terminations are critical. The connector’s deadbreak functionality further enhances operational safety and efficiency, reducing the risk of arc flash and enabling quick, maintenance-friendly connections.
  • 600 Amp current rating for high-power applications
  • 15/25 kV voltage rating for medium-voltage systems
  • Aluminum compression lug for corrosion resistance and conductivity
  • Accommodates cable insulation diameters 1.280–1.430 inches
  • Supports conductor sizes: 500/600 kcmil or 250/300 mm² compact

Specifications

Amperage Rating
600 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
500 kcmil , 600 kcmil
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arrestors, and fault current indicators
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector
Voltage Rating
15 to 25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
6.4000 L
Package Weight (Metric)
2.9030 kg
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300. Cold-Shrinkable Jacket Seal Included.

K656LR-L0330-S

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300. Cold-Shrinkable Jacket Seal Included.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed/Stranded 650 or Compact/Solid 750 or mm2 Compact 400.

K655LR-L0360

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed/Stranded 650 or Compact/Solid 750 or mm2 Compact 400.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.

K655LR-L0330

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed/Stranded 700/750 or Compact/Solid 900.

K655LR-L0380

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed/Stranded 700/750 or Compact/Solid 900.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.

K655LR-L0300

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG Compressed/Stranded 4/0 or kcmil Compact/Solid 250 or mm2 Compact 125.

K655LR-L0270

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG Compressed/Stranded 4/0 or kcmil Compact/Solid 250 or mm2 Compact 125.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Bi-Metal Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K655LR-K5330-SG3

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Bi-Metal Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Bi-Metal Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K655LR-K5300-SG3

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Bi-Metal Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

Frequently Asked Questions

What is the maximum operating voltage for this elbow connector?

The elbow connector is rated for 15kV and 28kV voltage classes, with maximum phase-to-ground operating voltages of 8.3kV and 16.2kV respectively.

What conductor sizes can this connector accommodate?

It can be used with conductor sizes ranging from #2 AWG to 1250 kcmil for both aluminum and copper conductors.

What is the insulation diameter range for compatible cables?

The compatible insulation diameters range from 0.640 inches to 1.935 inches.

What standards does this deadbreak elbow meet?

This deadbreak elbow meets ANSI/IEEE Standard 386, Latest Revision.

What is the continuous current rating of the connector?

The connector has a continuous current rating of 600 Amps.

What is the momentary short-circuit current rating?

The momentary short-circuit current rating is 25kA Sym for 10 Cycles.

What is the impulse withstand rating (BIL) for the 28kV class?

For the 28kV voltage class, the Impulse Withstand (BIL) is 140kV.

What is the AC one-minute withstand voltage for the 15kV class?

For the 15kV voltage class, the AC one-minute withstand voltage is 34kV.

What is the DC fifteen-minute withstand voltage for the 28kV class?

For the 28kV voltage class, the DC fifteen-minute withstand voltage is 84kV.

What is the corona extinction rating for the 15kV class?

The corona extinction rating for the 15kV class is 11kV AC at 3pC sensitivity.

How to Install K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and wiring of K655/K675LR Deadbreak Elbow Connectors on high voltage apparatus, including cable preparation, lug crimping, and grounding procedures.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Wire brush (for aluminum conductors), Hotstick, Suitable voltage sensing device, Torque wrench (for mating parts and L-Kits), Suitable grounding connector

Supplies needed:

K655/K675LR Deadbreak Elbow Connector kit (Elbow, Cable Adapter, Compression Lug, Insulating Plug, Lubricant, Stud Prepack), No. 14 AWG Copper wire (or equivalent), Silicone lubricant, Waterproofing material (for cable jacket)

  1. Ensure De-energized State and Prepare Work Area

    De-energize all apparatus in the work area. Do not touch or move energized products. Inspect all parts for damage, rating, and compatibility. Gather all required tools and supplies, and maintain cleanliness.

  2. Prepare the Cable

    Position the cable with enough slack. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4" (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24" (610mm). Remove the outer jacket (if applicable) and prepare the cable according to the specific cable type (e.g., Unishield, Jacketed, Non-Jacketed) and the provided diagrams, ensuring correct insulation and semi-con shield dimensions.

  3. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4" (6mm) back. Thoroughly clean and lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Prepare and Crimp Conductor

    Remove protruding cable insulation, cutting it even with the cable adapter. Ensure exposed conductor length is 4-1/4" to 4-9/16" (108mm-116mm). For copper, fully insert conductor into compression lug. For aluminum, wire brush and immediately insert. Measure "Check Dimension" (< 6-3/8") before crimping. Crimp lug per its instructions. Wipe excess inhibitor. Verify distance from lug end to cable adapter is 6-3/8" to 7-1/8" (162mm-181mm) after crimping.

  5. Install Elbow onto Cable Adapter

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Confirm the cable adapter remains flush with the tape marker. Reposition if necessary, then remove the tape marker.

  6. Connect Elbow to Mating Product

    Remove protective caps from the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud supplied with the elbow into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant. Push the elbow onto the mating part, aligning the hole in the compression lug with the stud on the mating part.

  7. Connect Opposite End Mating Product (if applicable)

    Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to its specific instructions. If an insulating plug is used, clean and lubricate its inner surface and place it on the elbow, pushing until it snaps into place.

  8. Ground the Cable Shield

    Insert one end of a No. 14 AWG Copper wire (or equivalent) through the grounding eye and twist to form a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. Ensure the cable shield is grounded, either through a grounding device or an alternate method. Waterproof the cable jacket at this point to prevent moisture ingress.

  9. Perform Voltage Test (Optional but Recommended)

    If performing a voltage test, remove the test point cap with a hotstick by peeling it off at an angle. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Do not use conventional voltage measuring equipment. Treat the elbow as energized until the "no voltage" indication is confirmed by other means to prevent serious injury. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.