ABB - Installation Products K655LR-L0360 - 600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed/Stranded 650 or Compact/Solid 750 or mm2 Compact 400.

ABB Installation Products K655LR-L0360 600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and…

UPC: 783786835997


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products K655LR-L0360 is a 600 Amp, 15/25kV deadbreak elbow connector designed for medium-voltage cable systems. This deadbreak product includes an insulated plug, cap, stud, lug, and cable adapter, providing a complete termination solution for reliable electrical connections. The aluminum compression lug ensures secure conductor termination, while the cable insulation diameter range of 1.180 inch to 1.465 inch accommodates a variety of cable sizes. The connector supports conductor sizes of 650 or 750 kcmil in compressed or stranded configurations, and 400 mm² in compact configurations. This deadbreak elbow is suitable for use in underground distribution systems, switchgear, and pad-mounted transformers where safe, insulated disconnection is required. The product meets industry standards for medium-voltage applications, ensuring long-term reliability and electrical integrity. The K655LR-L0360 is part of ABB’s 600 Series, a trusted line of medium-voltage connectors designed for durability and ease of installation in utility and industrial environments.
  • 600 Amp, 15/25kV deadbreak elbow connector
  • Includes insulated plug, cap, stud, lug, and cable adapter
  • Aluminum compression lug for secure conductor termination
  • Cable insulation diameter range: 1.180 inch to 1.465 inch
  • Supports conductor sizes: 650/750 kcmil (compressed/stranded) or 400 mm² (compact)

Specifications

Amperage Rating
600 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
650 kcmil , 750 to 800 kcmil
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arrestors, and fault current indicators
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector
Voltage Rating
15 to 25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
6.7500 L
Package Weight (Metric)
3.0620 kg
15/25kV 600 Series Deadbreak 3-Way L-Kit, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.

K655L3-LM0360

15/25kV 600 Series Deadbreak 3-Way L-Kit, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.

K655LR-L0330

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed/Stranded 700/750 or Compact/Solid 900.

K655LR-L0380

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed/Stranded 700/750 or Compact/Solid 900.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.

K655LR-L0300

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG Compressed/Stranded 4/0 or kcmil Compact/Solid 250 or mm2 Compact 125.

K655LR-L0270

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG Compressed/Stranded 4/0 or kcmil Compact/Solid 250 or mm2 Compact 125.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Bi-Metal Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K655LR-K5330-SG3

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Bi-Metal Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Bi-Metal Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K655LR-K5300-SG3

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Bi-Metal Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
15-25kv 600 Amp Dead Break Elbow With Sealing. Bi-Metal Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG Compressed/Stranded 3/0 or Compact/Solid 4/0 or mm2 Compact 95.

K655LR-K5260-S

15-25kv 600 Amp Dead Break Elbow With Sealing. Bi-Metal Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG Compressed/Stranded 3/0 or Compact/Solid 4/0 or mm2 Compact 95.

Frequently Asked Questions

What is the maximum operating voltage for the K655LR elbow connector?

For the 15kV voltage class, the maximum operating voltage is 8.3kV phase-to-ground. For the 28kV voltage class, it is 16.2kV phase-to-ground.

What conductor sizes can the K655LR handle?

The K655LR can be used with conductor sizes from #2 AWG to 1250 kcmil for both aluminum and copper conductors.

What is the insulation diameter range for this elbow connector?

The insulation diameters range from 0.640 inches to 1.935 inches.

What is the continuous current rating for the K655LR?

The K655LR has a continuous current rating of 600 Amps.

What is the momentary current rating for the K655LR?

The K655LR has a momentary current rating of 25kA Sym for 10 Cycles.

What is the impulse withstand rating for the 28kV voltage class?

The impulse withstand rating for the 28kV voltage class is 140kV BIL (1.2 x 50 microsecond wave).

What is the AC one-minute withstand for the 15kV voltage class?

The AC one-minute withstand for the 15kV voltage class is 34kV.

What is the AC one-minute withstand for the 28kV voltage class?

The AC one-minute withstand for the 28kV voltage class is 45kV.

What is the corona extinction rating for the 28kV voltage class?

The corona extinction rating for the 28kV voltage class is 21.5kV AC @ 3pC sensitivity.

What standards does the K655LR meet?

The K655LR meets ANSI/IEEE Standard 386, Latest Revision.

How to Install Elastimold 655/675LR and K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of Elastimold 655/675LR and K655/K675LR Deadbreak Elbow Connectors, designed for high voltage cable connections to apparatus and for splicing/tapping systems.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimp tool (for compression lug), Wire brush (for aluminum conductors), Hotstick (for voltage test cap removal), Suitable voltage sensing device (for capacitive test point), Torque wrench (for mating parts and L-kits)

Supplies needed:

Elbow connector, Cable adapter, Compression lug, Insulating plug (if applicable), Lubricant (supplied), Threaded stud (if mating part not equipped), Grounding wire (at least No. 14 AWG Copper equivalent), Suitable ground connector, Silicone lubricant (for test point cap), Waterproofing material (for cable jacket, recommended)

  1. Ensure Safety and Perform Initial Checks

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. Inspect all package contents for completeness and damage. Verify all components fit properly with the cable and/or mating products. Gather all required tools and maintain cleanliness throughout the procedure. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices.

  2. Prepare the Cable for Connection

    Assemble the cable in its final position, ensuring enough slack for elbow removal. If using concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent back concentric neutral wires. Prepare the cable by removing the outer jacket (if applicable) and other layers according to the specific cable type (e.g., Unishield, Jacketed, Non-Jacketed) and the provided diagrams or separate instructions for grounding devices/cable seals.

  3. Install the Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Prepare the Conductor

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of the exposed conductor must be between 4-1/4 inches and 4-9/16 inches (108mm-116mm). If the length is incorrect, redo the assembly.

  5. Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the 'Check Dimension' before crimping; it should be less than 6-3/8 inches. Crimp the compression lug following the crimping instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping must be between 6-3/8 inches to 7-1/8 inches (162mm-181mm). If incorrect, redo the assembly.

  6. Install the Elbow onto the Cable

    Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; if not, reposition the cable adapter. Remove the tape marker.

  7. Prepare Mating Apparatus

    DANGER: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove any protective caps from the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud supplied with the elbow into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean.

  8. Connect the Elbow to the Mating Part

    Push the elbow onto the mating part, carefully lining up the hole in the compression lug with the stud on the mating part.

  9. Connect Opposite Mating Product (if applicable)

    Clean and lubricate the mating part intended for the opposite end of the elbow. Insert this mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to the instructions supplied with that specific mating part.

  10. Install Insulating Plug (if used)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down hard until it snaps into place. Proceed to the voltage test directions.

  11. Ground the Cable Shield

    Insert one end of a grounding wire (with ampacity at least equivalent to No. 14 AWG Copper) through the grounding eye and twist to form a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded; follow instructions supplied with any grounding device or use an alternate method if no device is used. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  12. Perform Voltage Test

    WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Remove the test point cap with a hotstick, peeling it off at an angle. Test with a suitable sensing device, designed for capacitive test points, to determine if the cable is energized. Contamination or incorrect equipment can give a false 'no voltage' indication; treat the elbow as energized until confirmed by other means to prevent serious injury. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.