ABB - Installation Products K655LR-G5270-S - 600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Bi-Metal Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG Compressed/Stranded 4/0 or kcmil Compact/Solid 250 or mm2 Compact 125. Cold-Shrinkable Jacket Seal Included.

ABB Installation Products K655LR-G5270-S 600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and…

UPC: 075114144407


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K655LR-G5270-S is a 600 Amp, 15/25kV deadbreak elbow connector kit engineered for secure, fully shielded medium-voltage cable connections in electrical distribution and transmission networks. This kit includes an insulated plug, cap, stud, bi-metal compression lug, and cable adapter, providing a complete solution for deadfront submersible applications. The bi-metal compression lug accommodates compressed/stranded conductors from 4/0 AWG to 250 kcmil and compact/solid conductors up to 125 mm², ensuring compatibility with both copper and aluminum cables. The cable insulation diameter range is 0.760 inches to 0.950 inches, with a cold-shrinkable jacket seal included for environmental protection against moisture and contaminants. Designed for de-energized connections and disconnections using standard hand tools, this elbow connector meets ANSI/IEEE Standard 386 and is rated for 15/25kV applications with a maximum phase-to-ground operating voltage of 8.3kV (15kV class) or 16.2kV (25kV class). The unit delivers 600 Amp continuous current and 25kA symmetrical momentary withstand for 10 cycles, making it suitable for high-voltage apparatus and submersible environments. Typical applications include connections to transformers, switchgear, and other high-voltage equipment where fully shielded, deadfront terminations are required.
  • 600 Amp, 15/25kV deadbreak elbow connector kit for medium-voltage applications
  • Bi-metal compression lug compatible with 4/0 AWG to 250 kcmil compressed/stranded and 125 mm² compact/solid conductors
  • Cable insulation diameter range: 0.760" to 0.950" with cold-shrinkable jacket seal for environmental protection
  • Fully shielded, deadfront submersible design for secure high-voltage cable connections
  • Meets ANSI/IEEE Standard 386; rated 600A continuous, 25kA momentary withstand

Specifications

Amperage Rating
600 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection Type
Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter
Connection Type
Compression Lug
Current Rating
600 A
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Bi-Metal Compression Lug, Cold-Shrinkable Jacket Seal
Material
Housing - EPDM-Rubber
Material
Bi-Metal (Copper/Aluminum), Cold-Shrinkable Jacket Seal
Series
600 Series
Size
Cable Insulation Diameter 0.760 inch to 0.950 inch
Size
Cable Insulation Diameter: 0.760-0.950 inch, Conductor Size: 4/0 AWG to 250 kcmil (Compact/Stranded) or 125 mm² (Compact/Solid)
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arrestors, and fault current indicators
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

162LR-D5270-S

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG Compressed/Stranded 4/0 or kcmil Compact/Solid 250 or mm2 Compact 125.

K655LR-K0270

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG Compressed/Stranded 4/0 or kcmil Compact/Solid 250 or mm2 Compact 125.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.

K655LR-K0300

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Copper Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.

K655LR-J2300

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Copper Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Copper Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed/Stranded 4/0 or kcmil Compact/Solid 250 or mm2 Compact 125. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K655LR-H2270-SG3

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Copper Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed/Stranded 4/0 or kcmil Compact/Solid 250 or mm2 Compact 125. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Copper Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K655LR-J2300-SG3

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Copper Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Copper Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.

K655LR-G2240

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Copper Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Copper Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size kcmil Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150.

K655LR-H2290

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Copper Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size kcmil Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150.

Frequently Asked Questions

What is the maximum operating voltage for this elbow connector?

The elbow connector is rated for 15/25kV, with a maximum operating voltage of 8.3kV phase-to-ground for 15kV class and 16.2kV phase-to-ground for 28kV class.

What conductor sizes can this elbow connector accommodate?

It can be used with conductor sizes ranging from #2 AWG to 1250 kcmil for both aluminum and copper conductors.

What is the continuous current rating of the K655LR elbow connector?

The K655LR elbow connector has a continuous current rating of 600 Amps.

What is the insulation diameter range for this connector?

The connector is designed for insulation diameters ranging from 0.640 inches to 1.935 inches.

Is this elbow connector submersible?

Yes, the K655LR elbow connector features a fully shielded, fully submersible molded rubber housing.

What standards does this elbow connector meet?

The K655LR elbow connector meets ANSI/IEEE Standard 386, Latest Revision.

What is the impulse withstand rating for the 28kV class?

For the 28kV voltage class, the impulse withstand rating is 140kV BIL (1.2 x 50 microsecond wave).

What is the momentary current rating?

The elbow connector has a momentary current rating of 25kA Sym for 10 Cycles.

Can this elbow connector be easily connected or disconnected?

Yes, it can be easily connected or disconnected using standard hand tools and equipment in a de-energized state.

What accessories are available for this elbow connector?

Optional accessories are available for visible external separation, by-pass, isolation, dead-ending, grounding, testing, and adding taps, surge arrestors, and fault current indicators.

How to Install K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of K655/K675LR Deadbreak Elbow Connectors, including cable preparation, lug crimping, and connection to mating apparatus. Always ensure all apparatus are de-energized before beginning installation.

Estimated time: 1h 30m

Tools needed:

Cable cutting tool, Cable stripping tool, Beveling tool, Wire brush (for aluminum conductors), Crimping tool, Torque wrench, Hotstick, Suitable voltage sensing device, Cleaning cloths/wipes

Supplies needed:

K655/K675LR Deadbreak Elbow Connector (Elbow, Cable Adapter, Compression Lug, Insulating Plug, Lubricant, Stud Prepack), Tape marker, Grounding wire (at least No. 14 AWG Copper), Suitable grounding connector, Waterproofing material (for cable jacket), Mating apparatus/part (e.g., Apparatus Bushing, Tap Plug, Tap Well), HV insulated cap(s) or connector(s), Silicone lubricant

  1. Perform Pre-Installation Safety and Inspection

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products in the work area. Inspect all parts for damage, rating, and compatibility with mating parts. Ensure all components fit properly with the cable and/or mating products. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit.

  2. Prepare Cable for Connection

    Assemble the cable in its final position with enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24” (610mm). Remove the outer jacket (where applicable) and prepare the cable insulation and semi-con shield according to the product diagrams, ensuring specific dimensions (e.g., 9-3/4”, 10-3/4”, 12-3/4” from the cut end).

  3. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean, then lubricate the cable insulation, always working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Prepare Conductor and Crimp Compression Lug

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of exposed conductor must be between 4-1/4” and 4-9/16” (108mm-116mm). For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. For copper conductors, fully insert the conductor. Measure the 'Check Dimension' (must be less than 6-3/8”) before crimping. Crimp the compression lug following its supplied instructions. Wipe off all excess inhibitor. Verify the distance from the end of the compression lug to the cable adapter is between 6-3/8” to 7-1/8” (162mm-181mm).

  5. Install Elbow onto Cable Adapter

    Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Make sure the cable adapter is still flush with the tape marker. If not, reposition the cable adapter. Remove the tape marker.

  6. Connect Elbow to Mating Apparatus

    DANGER: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove protective caps from both the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud supplied with the elbow into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant. Push the elbow onto the mating part, lining up the hole in the compression lug with the stud on the mating part. If connecting to the opposite end of the elbow, clean and lubricate that mating part, insert it into the elbow, engage the threads, hand tighten, and then torque according to the mating part's instructions.

  7. Install Insulating Plug (if applicable)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap and place it on the elbow. Push down hard until the cap snaps into place.

  8. Ground the Cable Shield and Waterproof Jacket

    Insert one end of a piece of wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, ensuring not to damage the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded; ground according to the instructions supplied with the grounding device or through an alternate method if no device is used. It is also recommended that the jacket of the cable be waterproofed at this point to prevent moisture from entering the cable.

  9. Perform Voltage Test

    Remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly in line. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Test with a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. Treat the elbow as energized until the 'no voltage' test point indication is confirmed by other means. After voltage detection, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.