Authorized ABB Distributor (Installation Products)
ABB - Installation Products K655L4-J0330 - 15-25kV, 600 Amp, Deadbreak, 4-Way L-Kit without Test Point, without Seal. 38.18 inch (969.8mm). Cable Insulation Diameter 0.980 - 1.180 inches (24.9-30.0mm). Aluminum Compression Lug. Conductor Size 330 - 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact.

ABB Installation Products K655L4-J0330 15-25kV, 600 Amp, Deadbreak, 4-Way L-Kit without Test Point, without Seal. 38.18 inch…

UPC: 075114341288


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K655L4-J0330 is a 4-way deadbreak L-kit designed for reliable power distribution in medium voltage applications. Rated for 15-25 kV and 600 Amps, this kit utilizes aluminum compression lugs for secure conductor connections. It accommodates cable insulation diameters ranging from 0.980 to 1.180 inches (24.9-30.0mm). The L-kit is suitable for conductor sizes of 330 - 500 kcmil stranded/compressed or 600 kcmil solid/compact aluminum conductors. The overall length of the kit is 38.18 inches (969.8mm). This specific configuration does not include a test point or seal, making it ideal for applications where these features are not required or are handled by separate components. The 4-way configuration allows for efficient branching of power circuits. ABB's Installation Products are known for their robust design and dependable performance in electrical infrastructure. This deadbreak L-kit is a key component for utility, industrial, and commercial power systems requiring safe and efficient cable terminations. Its construction with aluminum compression lugs ensures a low-resistance connection, critical for maintaining system integrity and minimizing energy loss. The K655L4 series offers a standardized approach to deadbreak terminations, simplifying installation and maintenance procedures for electrical technicians. Ensure compatibility with your specific cable type and conductor size before installation. SKU: K655L4-J0330. Manufacturer: ABB - Installation Products. UNSPSC Code: 39121421.
  • Voltage Rating: 15-25 kV
  • Current Rating: 600 A
  • Configuration: 4-Way Deadbreak L-Kit
  • Conductor Size: 330-500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact
  • Cable Insulation Diameter: 0.980 - 1.180 inches (24.9-30.0mm)

Specifications

Amperage Rating
600 A
Application
Used to split one line into three on in, out, tap and using the two insulating plugs as test points allows for capacitive voltage testing
Color
Black
Conductor Range
500 kcmil , 600 kcmil
Connection
Compression
Environmental Conditions
Fully Submersible
Insulation
True
Length
10.87 in
Length
276.098 mm
Material
Housing - EPDM-Rubber
Special Features
No Seal
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak 4-Way L Kit
Voltage Rating
15 to 25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.

K655LR-J0330

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.
15/25kV, 600 Amp, Separable Wye Joint (3-Way) with Test Point, Spiking Aid, Cable Insulation 1.090-1.310 inches, Aluminum Compression Lug, Conductor Size 450 Stranded/Compressed kcmil or 500/550 Solid/Compact kcmil, Cold Shrinkable Seal with Copper Rod and Crimp Connector

K656CYSL-K0320-SG1

15/25kV, 600 Amp, Separable Wye Joint (3-Way) with Test Point, Spiking Aid, Cable Insulation 1.090-1.310 inches, Aluminum Compression Lug, Conductor Size 450 Stranded/Compressed kcmil or 500/550 Solid/Compact kcmil, Cold Shrinkable Seal with Copper Rod and Crimp Connector
25kv, 600 Amp Series, Deadbreak Combo-T. Connector Elbow with Integral 200 Amp Loadbreak Tap Plug with Test Point. Cable Insulation Diameter 1.180-1.465 inches (30.0-37.2 mm). Aluminum Conductor Material, Conductor Code 320 - 450 Stranded/Compressed or 500/550 Solid/Compact. No Sealing Kit.

K656CETP-L0320

25kv, 600 Amp Series, Deadbreak Combo-T. Connector Elbow with Integral 200 Amp Loadbreak Tap Plug with Test Point. Cable Insulation Diameter 1.180-1.465 inches (30.0-37.2 mm). Aluminum Conductor Material, Conductor Code 320 - 450 Stranded/Compressed or 500/550 Solid/Compact. No Sealing Kit.
15/25kV, 600 Amp, Separable H Joint (4-Way) with Test Point, Spiking Aid, Cable Insulation 1.180-1.465 inches, Aluminum Compression Lug, Conductor Size 450 Stranded/Compressed, Cold Shrinkable Seal with Copper Rod and Crimp Connector

K656CHSL-L0320-SG1

15/25kV, 600 Amp, Separable H Joint (4-Way) with Test Point, Spiking Aid, Cable Insulation 1.180-1.465 inches, Aluminum Compression Lug, Conductor Size 450 Stranded/Compressed, Cold Shrinkable Seal with Copper Rod and Crimp Connector
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold Shrinkable Jacket Seal.

K656I-M0380-S

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold Shrinkable Jacket Seal.
600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow with Test Point, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold-Shrinkable Jacket Seal.

K656RLR-P0380-S

600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow with Test Point, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold-Shrinkable Jacket Seal.
600 Amp, 25kV, Deadbreak Elbow, Window Op Connector Kit with Test Point. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

K656ETP-N0380

600 Amp, 25kV, Deadbreak Elbow, Window Op Connector Kit with Test Point. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300. Cold Shrinkable Seal with Copper Braid and Constant Spring Force Included.

K655LRL0330-SG3

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300. Cold Shrinkable Seal with Copper Braid and Constant Spring Force Included.

Frequently Asked Questions

What is the K655L4 L-Kit used for?

The K655L4 L-Kit is used to split one line into three (in, out, tap, tap). Its insulating plugs also allow for capacitive voltage testing.

What is the continuous current rating for both classes?

For both the 15kV and 28kV voltage classes, the continuous current rating is 600 Amp.

What specific items are included in each K655L4 kit?

Each K655L4 kit contains 4 Basic Elbow K655BLR, 11 tubes of lubricant 82-08, 2 Basic Insulating Plug K650BIP, 4 Stud 650SA, 3 Connecting Plug K651CP, and three installation instructions.

What functions do optional accessories provide?

Optional accessories allow for visible external separation, by-pass, isolation, dead-ending, grounding, and testing of the K655L4.

How is the K655L4 connected or disconnected?

The K655L4 can be easily connected or disconnected using standard hand tools and equipment in a de-energized state.

What materials are used in the K655L4's construction?

The K655L4 features 100% peroxide-cured construction, including insulation and conductive EPDM materials.

What type of housing does the K655L4 kit have?

The K655L4 kit features a fully shielded, fully submersible molded rubber housing.

What is the 28kV class BIL impulse withstand?

For the 28kV voltage class, the Basic Impulse Level (BIL) impulse withstand is 140kV.

What is the 28kV class maximum operating voltage?

For the 28kV class, the maximum phase-to-ground operating voltage is 16.2kV, and the maximum phase-to-phase is 28kV.

What is the 15kV class BIL impulse withstand?

For the 15kV voltage class, the Basic Impulse Level (BIL) impulse withstand is 95kV.

How to Install the 600/900 Series Deadbreak Connecting Plug

This guide provides step-by-step instructions for safely installing and connecting the 600/900 Series Deadbreak Connecting Plug with its mating part, including lubrication and grounding procedures.

Estimated time: 30m

Tools needed:

Torque wrench, 3/8 inch hex bit socket, 600ATM (optional)

Supplies needed:

Lubricant (supplied), No. 14 AWG (2.5mm) copper wire (if grounding is applicable)

  1. Perform Safety Checks and De-energize Apparatus

    Before beginning installation, ensure all apparatus in the work area are de-energized. Verify that all components are undamaged, rated correctly, and compatible with mating parts. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices. Failure to follow these instructions will result in damage to the product and serious or fatal injury.

  2. Install the Stud (if applicable)

    If the mating plug device is not equipped with a stud, hand tighten the stud into the mating plug device. Ensure the stud is threaded in until the start of the flats are below the contact surface.

  3. Clean and Lubricate Parts

    Clean both the connecting plug and its mating part (elbow, bushing extender, vault stretcher, or elbow end module) as indicated in the diagram. Apply the supplied lubricant to the connecting plug, stud, and the mating part. DO NOT SUBSTITUTE the lubricant, as other types may be harmful to the products. Keep all surfaces clean during this procedure.

  4. Connect and Torque the Plug

    Push the connecting plug firmly into the mating part (elbow, bushing extender, vault stretcher, or elbow end module) and engage the threads. Hold the contact of the connecting plug against the contact surface of the mating part. Using a 600ATM or a 3/8 inch hex bit socket and a torque wrench, tighten the connection to 50 to 60 foot-pounds (68 to 81 newton-meters) of torque.

  5. Ground the Connecting Plug (if applicable)

    If applicable, insert one end of a No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the connecting plug. Twist the wire tightly, taking care not to damage the eye. Connect the other end of the wire securely to ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.