ABB - Installation Products K655ETP-M0380 - 25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

ABB Installation Products K655ETP-M0380 25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 1.370…

UPC: 783786534609


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K655ETP-M0380 is a 25kV, 600 Amp deadbreak connector kit designed for medium-voltage cable testing and grounding applications. This kit accommodates cable insulation diameters ranging from 1.370 inches to 1.630 inches, ensuring compatibility with a defined range of medium-voltage cables. It features an aluminum compression lug for conductors sized at 700/750 kcmil (compressed stranded) or 900 kcmil (compacted solid). The kit includes a hex-broach for precise torque installation and peroxide-cured insulation and jacket for durability. The blue loadbreak interface signifies a 15kV class, offers enhanced visibility, and acts as a seating indicator. The 600A interface supports continuous current up to 600A with a 25kA symmetrical momentary current rating for 10 cycles. The 200A loadbreak tap interface supports continuous and load break operations up to 200A with a 10kA symmetrical fault close rating. This connector meets ANSI/IEEE Standard 386 requirements, including 125kV BIL impulse withstand, 40kV AC one-minute withstand, and 78kV DC 15-minute withstand. Applications include test points, grounding, arrester installations, and load taps in medium-voltage electrical distribution networks. The K655ETP-M0380 is part of ABB's 600 Series Deadbreak Connector family, engineered for safe and efficient maintenance in critical power systems. It is rated for 25/28 kV voltage class, with a 25 kV maximum phase-to-phase rating and 16.18 kV phase-to-ground rating. The 200A interface is rated for 10kA symmetrical 10-cycle fault close operations.
  • 25kV, 600 Amp deadbreak connector kit for medium-voltage applications
  • Accommodates cable insulation diameters from 1.370" to 1.630"
  • Aluminum compression lug for 700/750 kcmil stranded or 900 kcmil solid conductors
  • Includes hex-broach for precise torque installation
  • 200A loadbreak tap interface for energized operations

Specifications

Amperage Rating
600 A
Application
600 Amps, 25kV
Color
Black
Conductor Range
700 to 750 STR/COMPR kcmil , 900 SOL/COMPT kcmil
Connection
Compression
Connection Type
Deadbreak
Connection Type
Compression Lug
Current Rating
600 A
Insulation
EPDM Rubber
Material
Aluminum
Material
Housing - EPDM-Rubber
Series
600
Series
600 Series
Size
Cable Insulation Diameter 1.370 inch to 1.630 inch
Size
1.370 inch to 1.630 inch
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Window-Op Connector
Voltage Rating
25kV
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. 200ECS Cold-Shrinkable Jacket Seal Included.

655ETP-M0380-S

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. 200ECS Cold-Shrinkable Jacket Seal Included.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

655ETP-N0410

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50.

656ETP-G0230-DRG

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50.
25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold-Shrinkable Jacket Seal Included.

K655ETP-M0380-S

25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold-Shrinkable Jacket Seal Included.
600 Amp, 35kV, Deadbreak, Elbow Tap Plug, Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50. With Insulated Cap.

756ETP-H0230-DRG

600 Amp, 35kV, Deadbreak, Elbow Tap Plug, Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50. With Insulated Cap.
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

655ETP-L0330-DRG

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
600 Amp, 35kV, Deadbreak, Elbow Tap Plug, Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. With Insulated Cap. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.

756ETP-N0400-DRG

600 Amp, 35kV, Deadbreak, Elbow Tap Plug, Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. With Insulated Cap. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.

Frequently Asked Questions

What is the primary application of WINDOW-OP connectors?

WINDOW-OP connectors allow direct testing and grounding without cable movement. They are ideal for equipment with viewing windows for visible breaks.

What is the momentary current rating?

The momentary current rating is 25kA Symmetrical for 10 Cycles.

What is the corona extinction voltage?

The corona extinction voltage is 21.5kV AC at 3pC sensitivity.

What is the 15-minute DC withstand voltage?

The 15-minute DC withstand voltage for the connector is 84kV.

What is the one-minute AC withstand voltage?

The one-minute AC withstand voltage for the connector is 45kV.

What is the impulse withstand (BIL) rating?

The impulse withstand (BIL) rating is 140kV (1.2 x 50 microsecond wave).

What is the continuous current rating of the connector?

The WINDOW-OP Connector Kit has a continuous current rating of 600 Amps.

What is the maximum operating voltage for this connector?

The maximum phase-to-ground operating voltage for the 28kV Voltage Class is 16.2kV. The maximum phase-to-phase voltage is 28kV.

Which ANSI/IEEE standard does the connector meet?

The WINDOW-OP Connector Kit meets ANSI/IEEE Standard 386, Latest Revision.

What is the one-minute AC withstand voltage?

The one-minute AC withstand voltage for the connector is 45kV.

How to Install the 160DRG/167DRG Insulated Cap with Ground Lead

This guide provides instructions for installing the ELASTIMOLD 15kV class 160DRG and 167DRG insulated caps with ground lead, designed for insulating, shielding, and watersealing loadbreak bushing interfaces. Ensure all apparatus is de-energized during installation.

Estimated time: 15m

Tools needed:

Hotstick, Live-line tool

Supplies needed:

Insulated Cap with Ground Lead, Lubricant

  1. Connect Electrostatic Grounding Wire

    Connect the free end of the electrostatic grounding wire to the system ground. Leave enough slack for hot-stick operation of the insulated cap. CAUTION: Train the electrostatic grounding wire so as not to contact the bushing interface during operation. DANGER: All apparatus must be de-energized during installation or removal of parts.

  2. Lubricate Insulated Cap

    Remove the protective cover from the insulated cap. Lubricate the cap's internal mating surface using only the supplied lubricant or ELASTIMOLD approved lubricants. DO NOT SUBSTITUTE, as other lubricants may be harmful. Keep the internal mating surface free from dirt and grime. Always replace the protective cover when the cap is not in use.

  3. Attach Cap to Loadbreak Bushing

    Firmly attach a hotstick to the insulated cap's pulling eye. Insert the male contact of the insulated cap into the loadbreak bushing, and push it home with a fast, firm, straight motion. Make certain it is fully mated, with the locking ring seated. Detach the hotstick from the insulated cap.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.