ABB - Installation Products 655ETP-L0330-DRG - 15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

ABB Installation Products 655ETP-L0330-DRG 15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test…

UPC: 783786570386


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products 655ETP-L0330-DRG is a 15kV 600 Series Deadbreak Elbow TAP PLUG Connector Kit designed for reliable medium-voltage cable connections. This kit includes a test and ground reducing tap plug, 600 series elbow housing, cable adapter, and 0370 style aluminum compression lug, ensuring compatibility with compressed stranded conductors (500 kcmil), compacted solid conductors (600 kcmil), or compacted mm² conductors (250/300 mm²). The connector accommodates cable insulation diameters from 1.180 inch to 1.465 inch, providing a secure fit for medium-voltage applications. The deadbreak design allows for safe, load-break operation under energized conditions, making it ideal for underground distribution systems, pad-mounted transformers, and switchgear installations. The aluminum compression lug ensures low-resistance connections, while the 600 series elbow housing provides mechanical protection and environmental sealing. The test and ground feature enables temporary grounding for maintenance or testing without de-energizing the system, enhancing operational safety. This connector kit is engineered for use in utility, industrial, and commercial power distribution networks where 15kV-rated components are required. The compression-style connection ensures long-term reliability and minimizes the risk of loose terminations. Compliance with industry standards for medium-voltage connectors ensures consistent performance in harsh environments, including exposure to moisture, contaminants, and temperature fluctuations. For applications requiring a deadbreak elbow tap plug with grounding capability, the ABB 655ETP-L0330-DRG delivers a complete solution with verified compatibility across a range of conductor sizes and insulation diameters.
  • 15kV voltage rating for medium-voltage applications
  • Includes test and ground reducing tap plug, 600 series elbow housing, cable adapter, and 0370 aluminum compression lug
  • Accommodates cable insulation diameters from 1.180 inch to 1.465 inch
  • Compatible with compressed stranded (500 kcmil), compacted solid (600 kcmil), or compacted mm² (250/300 mm²) conductors
  • Deadbreak design enables safe load-break operation under energized conditions

Specifications

Amperage Rating
600 A
Application
600 Amps, 15kV
Color
Black
Conductor Range
500 STR/COMPR kcmil , 600 SOL/COMPT kcmil
Connection
Compression
Insulation
EPDM Rubber
Material
Housing - EPDM-Rubber
Size
Cable Insulation Diameter 1.180 inch to 1.465 inch
Special Features
Includes Insulated Cap
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Window-Op Connector
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. 200ECS Cold-Shrinkable Jacket Seal Included.

655ETP-L0330-DRG-S

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. 200ECS Cold-Shrinkable Jacket Seal Included.
600 Amp, 35kV, Deadbreak, Elbow Tap Plug, Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. With Insulated Cap. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.

756ETP-N0400-DRG

600 Amp, 35kV, Deadbreak, Elbow Tap Plug, Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. With Insulated Cap. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.
25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Insulated Cap. Cold-Shrinkable Jacket Seal Included.

K655ETP-N0380-DRG-S

25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Insulated Cap. Cold-Shrinkable Jacket Seal Included.
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

655ETP-M0380

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

655ETP-M0380-DRG

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50. Cold-Shrinkable Jacket Seal Included.

K655ETP-G-0230S

25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50. Cold-Shrinkable Jacket Seal Included.
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. 200ECS Cold-Shrinkable Jacket Seal Included.

655ETP-M0380-S

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. 200ECS Cold-Shrinkable Jacket Seal Included.
600 Amp, 35kV, Deadbreak, Test and Ground Connector kit, includes Insulated cap, reducing tap plug, elbow housing, cable adapter and 0370 style compression lug. 600ATM assembly tool required, 50-60 foot/pounds torque wrench required but not included. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.

755ETP-J0240-DRG

600 Amp, 35kV, Deadbreak, Test and Ground Connector kit, includes Insulated cap, reducing tap plug, elbow housing, cable adapter and 0370 style compression lug. 600ATM assembly tool required, 50-60 foot/pounds torque wrench required but not included. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.

Frequently Asked Questions

What is the continuous current rating?

The WINDOW-OP connector has a continuous current rating of 600 Amps.

What is the maximum operating voltage for this connector?

For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV. The maximum phase-to-phase voltage is 14.4kV.

What is the maximum operating voltage for this connector?

For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV. The maximum phase-to-phase voltage is 14.4kV.

What is the continuous current rating?

The WINDOW-OP connector has a continuous current rating of 600 Amps.

What are the main applications of WINDOW-OP connectors?

WINDOW-OP connectors allow direct testing and grounding without cable movement. They are ideal for equipment with viewing windows, providing a visible internal break without hotstick elbow removal.

What is the momentary current rating?

The momentary current rating is 25kA Symmetrical for 10 Cycles.

What is the corona extinction voltage?

The corona extinction voltage is 11kV AC at 3pC sensitivity.

What is the DC 15-minute withstand voltage rating?

The DC 15-minute withstand voltage rating for the connector is 53kV DC.

What is the AC one-minute withstand voltage rating?

The AC one-minute withstand voltage rating for the connector is 34kV AC.

What items are included in the connector kit?

Each kit contains a 600 Series Elbow Housing, WINDOW-OP LB Elbow Tap Plug, Insulated Cap, Cable Size Adapter, Compression Lug, Stud, Silicone Lubricant, and various instruction sheets.

How to Install the 655ETP-L0330-DRG Insulated Cap with Ground Lead

Instructions for installing and removing the 655ETP-L0330-DRG insulated cap with ground lead on a loadbreak bushing interface.

Estimated time: 30m

Tools needed:

Hotstick, Screwdriver (for system ground connection, if applicable)

Supplies needed:

Insulated Cap with Ground Lead, Lubricant (supplied or ELASTIMOLD approved), Mounting screws (if applicable for system ground)

  1. Connect the electrostatic grounding wire

    Connect the free end of the electrostatic grounding wire to the system ground. Ensure there is enough slack for hot-stick operation. CAUTION: Train the grounding wire so it does not contact the bushing interface during operation. WARNING: If the ground lead disconnects during operation, do not attempt to reattach without first pulling the insulated cap off the bushing with the hotstick.

  2. Prepare the insulated cap

    Remove the protective cover from the insulated cap. Lubricate the cap's internal mating surface using only the supplied lubricant or ELASTIMOLD approved lubricants. DO NOT SUBSTITUTE. Keep the internal mating surface free from dirt and grime. Always replace the protective cover when not in use.

  3. Install the insulated cap

    Firmly attach the hotstick to the insulated cap's pulling eye. Insert the male contact of the insulated cap into the loadbreak bushing. Push home with a fast, firm, straight motion, ensuring it is fully mated and the locking ring is seated. Detach the hotstick from the insulated cap.

  4. Remove the insulated cap

    Attach the hotstick to the pulling eye. Before pulling, rotate the insulated cap clockwise while in the mated position to break surface friction. Pull the receptacle off with a fast, firm, straight motion. Remove the electrostatic grounding wire of the insulated cap from the system ground. Replace the protective cover on the insulated cap to keep its internal surface clean.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.