ABB Installation Products J4-2226-35-TMA 4 Point Junction, with three 200 Amp Bushing Well Interfaces and one 600 Amp Bushing…
UPC: 783786463015
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 4-point junction with three 200A and one 600A bushing well interfaces
- 35 kV voltage rating for medium-voltage applications
- Tilt mounting adapter for flexible installation in tight spaces
- Part of ABB’s J4-2226 series for reliable power distribution
- Bushing well connections for quick and secure terminations
Specifications
Application | Suited for Subsurface, Vault or Padmount Applications and can be used for Sectionalizing, Looping, Tapping and Equipment Bypass |
Connection | Push-In |
Material | EPDM-Rubber and Stainless Steel Mounting Brackets |
Mounting | Tilt Mounting Adapter |
Size | Overall Length 23 inches, Width 6-3/4 inches |
Special Features | 4 inch Center Spacing |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Multi-Point Junction - 4 Points |
Package Dimensions (L x W x H) | 1 IN x 1 IN x 1 IN |
Package Dimensions (L x W x H) | 2.54 cm x 2.54 cm x 2.54 cm |
Package Weight (Imperial) | 26.5000 L |
Package Weight (Metric) | 12.0200 kg |

J6-622226-25
6 Point Junction, with one 600 Amp Bushing Interfaces, four 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 25kV, No Tilt Mounting.
J4-2266-15-TMA
4 Point Junction, with two 200 Amp Bushing Well Interfaces and two 600 Amp Bushing interface, 15kV, Tilt Mounting Adapter.
J4-2226-25-SV
4 Point Junction, with three 200 Amp Bushing Well Interfaces and one 600 Amp Bushing interface, 25kV, 6-1/2 inch centers. No Tilt Mounting.
J4-2266-15
4 Point Junction, with two 200 Amp Bushing Well Interfaces and two 600 Amp Bushing interface, 15kV, No Tilt Mounting.
J4-2226-25-SV-N
4 Point Junction, with three 200 Amp Bushing Well Interfaces and one 600 Amp Bushing interface, 25kV, 6-1/2 inch centers. No Parking Stand.
J4-2266-15-SV
4 Point Junction, with two 200 Amp Bushing Well Interfaces and two 600 Amp Bushing interface, 15kV, 6-1/2 inch centers. No Tilt Mounting.
J4-2226-15-TMA
4 Point Junction, with three 200 Amp Bushing Well Interfaces and one 600 Amp Bushing interface, 15kV, Tilt Mounting Adapter.
J4-2226-25
4 Point Junction, with three 200 Amp Bushing Well Interfaces and one 600 Amp Bushing interface, 25kV, No Tilt Mounting.Frequently Asked Questions
How are the interfaces identified in the catalog number?
In the catalog number, '2' identifies a 200 Amp Deepwell Interface, '6' identifies a 600 Amp Bushing Interface, and 'B' indicates a Blank Position.
What is the corona extinction voltage for a 35kV junction?
For a 35kV voltage class junction, the corona extinction is 26kV AC at 3pC sensitivity.
What are the momentary and fault close ratings for 200 Amp?
For 200 Amp, the momentary and fault close rating is 10kA Symmetrical for 10 cycles.
What are the momentary and fault close ratings for 600 Amp?
For 600 Amp, the momentary and fault close rating is 25kA Symmetrical for 10 cycles.
What are the available interface spacing options?
The junctions are available with standard 4-inch spacing or optional 6.5-inch spacing.
How many Tilt Mounting Adapters are needed?
Two Tilt Mounting Adapters are required to utilize this option.
What is the purpose of the Tilt Mounting Adapter (TMA)?
The Tilt Mounting Adapter bolts to the standard mounting bracket to provide adjustable angles of 15, 30, 45, or 60 degrees.
What is included in a standard junction kit?
Each kit contains a basic molded junction, mounting hardware, two tubes of lubricant, installation instructions, and a protective cap.
What is the maximum operating voltage for a 35kV junction?
For a 35kV voltage class junction, the maximum phase-to-ground operating voltage is 21.1kV.
What materials are used for the housing and brackets?
The housing is made of 100% peroxide-cured EPDM rubber, and the brackets use 304 stainless steel for corrosion prevention.
How to Install the J4-2226-35-TMA Deadbreak Junction with Universal Mount
This guide provides step-by-step instructions for safely installing the J4-2226-35-TMA deadbreak junction using the universal mounting method. It covers mounting, assembly, and grounding procedures, along with initial preparation for operation.
Estimated time: 1h
Tools needed:
Wrench, Wire strippers
Supplies needed:
Suitable mounting fasteners, 3/8" Hex Head Cap Screws, External Tooth Lock Washers (3/8"), 3/8" Hex Nuts, 1/2" Hex Head Cap Screws, 1/2" Split Lock Washers, 1/2" Hex Nuts, Grounding wire, ELASTIMOLD approved lubricant, HV insulated caps
- Ensure De-energized State
Before beginning installation, ensure all apparatus is de-energized. Verify the absence of voltage using appropriate safety procedures and equipment. Failure to do so can result in serious injury or death.
- Mark Mounting Locations
Determine the desired location for the junction assembly. Use the base plate as a template to mark the slot locations on the mounting surface.
- Mount Initial Universal Brackets
Secure two universal brackets to the marked surface using suitable fasteners. Tighten them securely to prevent any movement during operation.
- Assemble Remaining Universal Brackets
Attach the remaining two universal brackets to the previously mounted brackets at the desired angle. Use the supplied 3/8” hex head cap screws, external tooth lock washers, and 3/8” hex nuts. Tighten all connections securely.
- Assemble Junction to Base Bracket
Connect the deadbreak junction to the base bracket assembly and base plate. Use two 1/2” hex head cap screws, two 1/2” split lock washers, and two 1/2” hex nuts, attaching them to the center mounting holes on the bracket assembly. Tighten securely.
- Mount Junction Assembly
Attach the assembled deadbreak junction to the universal brackets. Use the supplied 1/2” hex head cap screws, 1/2” split lock washers, and 1/2” hex nuts. Tighten securely, and ensure the parking stand is in an upright position.
- Ground the Assembly
Connect a grounding wire to the grounding lug provided on the base bracket. Ensure the base bracket assembly and the junction’s black conductive jacket are properly grounded. The lug accommodates wire sizes from No. 2 solid to 1/0 stranded.
- Prepare Operating Interfaces
Remove all protective shipping caps from the junction. Clean each operating interface thoroughly and lubricate them with an ELASTIMOLD approved lubricant. Do not use substitute lubricants, as they may be harmful to the product.
- Install Insulated Caps (if needed)
If any operating interfaces are not utilized, install appropriate HV insulated caps on these unused bushings before energizing the circuit. Do not use the protective shipping caps for this purpose, as they are not insulated.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.