ABB - Installation Products J2-26-25-TMA - Multi-Point Junction, 2 Points, Interface Identification and Positioning - (1) 200 Amp Bushing Well Interface and (1) 600 Amp Bushing Interface, Voltage Class - 25/28kV, Standard Spacing - 4 inch centers, with Tilt Mounting Adapter - Bolts to the bottom of the standard Mounting bracket to provide 15, 30, 45 or 60 degree adjustable angle mounting. (Note - Two Mounting Adapters are rquired for each installation).

ABB Installation Products J2-26-25-TMA Multi-Point Junction, 2 Points, Interface Identification and Positioning - (1) 200 Amp…

UPC: 075114321839


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB J2-26-25-TMA Multi-Point Junction is a molded, fully shielded junction unit designed for medium-voltage electrical distribution systems. This 2-point junction features one 200 Amp deepwell interface and one 600 Amp bushing interface, rated for 25/28kV voltage class with 4-inch standard spacing between interfaces. The unit is constructed with 100% peroxide-cured EPDM materials, including conductive and insulating components, ensuring long-term reliability in submersible, vault, or padmount applications. Key specifications include a maximum phase-to-ground operating voltage of 16.2kV, 140kV BIL impulse withstand, 45kV AC one-minute withstand, and 84kV DC 15-minute withstand. The continuous current rating is 600 Amps with 25kA symmetrical momentary and fault close capability, or 200 Amps with 10kA symmetrical ratings. The junction meets ANSI/IEEE Standard 386 requirements and provides corona extinction at 21.5kV AC with 3pC sensitivity. The integrated Tilt Mounting Adapter bolts to standard mounting brackets, enabling adjustable installation angles of 15, 30, 45, or 60 degrees for optimized cable routing and accessibility. The 304 stainless steel brackets prevent rust and corrosion, while the fully submersible molded rubber housing ensures protection in harsh environments. This junction is designed for sectionalizing, looping, tapping, and equipment bypass applications in critical electrical infrastructure. Note: Two mounting adapters are required per installation. The SKU J2-26-25-TMA is part of ABB's Installation Products line, offering modular flexibility for medium-voltage distribution systems.
  • 25/28kV voltage class with 4-inch standard spacing
  • One 200 Amp deepwell interface and one 600 Amp bushing interface
  • Fully shielded, submersible molded rubber housing with EPDM construction
  • Adjustable tilt mounting (15°, 30°, 45°, 60°) via integrated adapter
  • Meets ANSI/IEEE Standard 386 with 140kV BIL impulse rating

Specifications

Application
Suited for Subsurface, Vault or Padmount Applications and can be used for Sectionalizing, Looping, Tapping and Equipment Bypass
Connection
Push-In
Connection Type
Bushing Well interface
Current Rating
200 A / 600 A
Material
EPDM-Rubber and Stainless Steel Mounting Brackets
Mounting
Tilt Mounting Adapter
Mounting Type
Tilt Mounting Adapter (15, 30, 45, 60 degrees)
Poles
2 Points
Series
J2
Size
4 inch Centers
Size
Overall Length 15 inches, Width 6-3/4 inches
Special Features
4 inch Center Spacing. Tilt Mounting Adapter
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Multi-Point Junction - 2 Points
Voltage Rating
25/28 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
6 Point Junction, with one 600 Amp Bushing Interfaces, four 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 25kV, No Tilt Mounting.

J6-622226-25

6 Point Junction, with one 600 Amp Bushing Interfaces, four 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 25kV, No Tilt Mounting.
15kV, 6 Point Multi-Point Junction, 2 x 200 Amp Bushing Well Interfaces, 4 x 600 Amp Bushing Interfaces, Standard Spacing of 4 inch centers. No Tilt Mounting

J6-226666-15

15kV, 6 Point Multi-Point Junction, 2 x 200 Amp Bushing Well Interfaces, 4 x 600 Amp Bushing Interfaces, Standard Spacing of 4 inch centers. No Tilt Mounting
25kV, Multi-Point Junction. 4-Points, 600 Amp Bushing Interface, (2) 300 Amp Bushing Well Interfaces, 600 Amp Bushing Interface. SV - Optional 6-1/2 inch Centers.

J4-6226-25-SV

25kV, Multi-Point Junction. 4-Points, 600 Amp Bushing Interface, (2) 300 Amp Bushing Well Interfaces, 600 Amp Bushing Interface. SV - Optional 6-1/2 inch Centers.
15kV, Multi-Port Junction, 6 Points, 600 Amp Bushing Interface, 2 x Blank Positions, 2 x 200 Amp Bushing Well Interface and 600 Amp Bushing Interfaces. Voltage Class 15kV, Standard 4 inchCenters Interface Spacing. TMA - Tilt Mounting Adapter. Bolts to the bottom of the standard mounting bracketg to provide 15, 30, 45 or 60 degree adjustable angle mounting.

J6-6BB226-15-TMA

15kV, Multi-Port Junction, 6 Points, 600 Amp Bushing Interface, 2 x Blank Positions, 2 x 200 Amp Bushing Well Interface and 600 Amp Bushing Interfaces. Voltage Class 15kV, Standard 4 inchCenters Interface Spacing. TMA - Tilt Mounting Adapter. Bolts to the bottom of the standard mounting bracketg to provide 15, 30, 45 or 60 degree adjustable angle mounting.
25kV, Multi-Point Junction. 2-Points, (2) 600 Amp Bushing Interfaces. R - Right Parking Stand.

J2-66-25-R

25kV, Multi-Point Junction. 2-Points, (2) 600 Amp Bushing Interfaces. R - Right Parking Stand.
4 Point Junction, with two 200 Amp Bushing Well Interfaces and two 600 Amp Bushing interface, 25kV, Left Parking Stand.

J4-2266-25-L

4 Point Junction, with two 200 Amp Bushing Well Interfaces and two 600 Amp Bushing interface, 25kV, Left Parking Stand.
900 Amp, 15/25kV, Deadbreak, Cable Adapter and Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

675CK-L2330

900 Amp, 15/25kV, Deadbreak, Cable Adapter and Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
900 Amp, 15/25kV, Deadbreak, Cable Adapter and Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

675CK-K2270

900 Amp, 15/25kV, Deadbreak, Cable Adapter and Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

Frequently Asked Questions

What is the voltage class of the ABB J2-26-25-TMA junction?

The ABB J2-26-25-TMA junction is rated for a voltage class of 25/28kV.

What are the current ratings for the bushing interfaces?

The junction features one 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface.

What is the standard spacing between the interfaces?

The standard spacing between the interfaces on the J2-26-25-TMA is 4 inches on center.

Does the junction include a mounting adapter?

Yes, it includes a Tilt Mounting Adapter that allows for adjustable mounting angles.

What adjustable angles does the Tilt Mounting Adapter offer?

The Tilt Mounting Adapter provides adjustable mounting angles of 15, 30, 45, or 60 degrees.

How many mounting adapters are needed per installation?

Two mounting adapters are required for each installation of the J2-26-25-TMA.

Who is the manufacturer of the J2-26-25-TMA junction?

The manufacturer of the J2-26-25-TMA junction is ABB - Installation Products.

How to Install a Deadbreak Junction with Universal Mount

This guide provides step-by-step instructions for installing a 15/25/35kV, 600/900 Ampere deadbreak junction using the universal mount method. It covers mounting, assembly, and grounding procedures, ensuring a secure and safe installation.

Estimated time: 1h

Tools needed:

Wrench or Socket Set (for 3/8" and 1/2" hex fasteners), Marking tool, Wire strippers

Supplies needed:

Deadbreak Junction, Base Bracket, Base Plate, Universal Brackets (4), Mounting Hardware Prepack (includes various screws, washers, nuts), Suitable fasteners (for attaching universal brackets to mounting surface), Grounding wire (No. 2 solid to 1/0 stranded), ELASTIMOLD approved lubricant, HV insulated caps (for unused bushings)

  1. Determine Mounting Location and Mark Slots

    DANGER: All apparatus must be de-energized during installation. Select the desired location for the junction assembly. Use the base plate as a template, place it on the mounting surface, and accurately mark all slot locations for the universal brackets.

  2. Mount Initial Universal Brackets

    Attach two universal brackets to the marked surface using suitable fasteners. Tighten them securely to prevent any movement during operation. Ensure the brackets are oriented correctly for the desired junction angle.

  3. Assemble Remaining Universal Brackets

    Connect the remaining two universal brackets to the previously mounted brackets at the desired angle using the supplied hardware (3/8” hex head cap screw, external tooth lock washer, and 3/8” hex nut). Tighten all connections securely to form the complete universal bracket assembly.

  4. Assemble Junction to Base Bracket and Plate

    Attach the deadbreak junction to the base bracket assembly and base plate. Use two 1/2” hex head cap screws, two 1/2” split lock washers, and two 1/2” hex nuts, securing them to the center mounting holes on the bracket assembly. Tighten all components securely.

  5. Mount Junction Assembly to Universal Brackets

    Secure the assembled deadbreak junction (with base bracket and plate) to the universal brackets using the supplied hardware (1/2” hex head cap screw, 1/2” split lock washer, and 1/2” hex nut). Ensure the parking stand is in the upright position before tightening all fasteners securely.

  6. Ground the Junction Assembly

    The base bracket assembly and the junction’s black conductive jacket must be properly grounded. Connect a grounding wire (No. 2 solid to 1/0 stranded) to the grounding lug provided on the base bracket. Ensure a secure and proper ground connection to prevent electrical hazards.

  7. Prepare for Operation

    Remove all protective shipping caps from the operating interfaces. Clean and lubricate each interface with an ELASTIMOLD approved lubricant; do not substitute. If any operating interfaces are not utilized, install appropriate HV insulated caps on the unused bushings before energizing the circuit. Do not use shipping caps for this function as they are not insulated.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.