ABB Installation Products J2-26-15 2 Point Junction, 15kV, with one 200 Amp Bushing Well Interface and one 600 Amp Bushing…
UPC: 783786459285
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 2-point molded multipoint junction for 15kV medium-voltage applications
- One 200 Amp deepwell and one 600 Amp bushing interface for flexible cable connections
- Fully shielded, fully submersible molded rubber housing with 304 stainless steel brackets
- Meets ANSI/IEEE Standard 386 with 95kV BIL impulse withstand and 34kV AC one-minute withstand
- No tilt mounting required; designed for direct burial, vault, or padmount installations
Specifications
Application | Suited for Subsurface, Vault or Padmount Applications and can be used for Sectionalizing, Looping, Tapping and Equipment Bypass |
Connection | Push-In |
Material | EPDM-Rubber and Stainless Steel Mounting Brackets |
Mounting | No Tilt Mounting Bracket |
Size | Overall Length 15 inches, Width 6-3/4 inches |
Special Features | 4 inch Center Spacing |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Multi-Point Junction - 2 Points |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

J6-622226-25
6 Point Junction, with one 600 Amp Bushing Interfaces, four 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 25kV, No Tilt Mounting.
J6-266662-25
6 Point Junction, with one 200 Amp Bushing Well Interfaces, four 600 Amp Bushing Interface and one 200 Amp Bushing Well Interface, 25kV, No Tilt Mounting.
J6-222266-15
6 Point Junction, with four 200 Amp Bushing Well Interfaces and two 600 Amp Bushing Interfaces, 15kV, No Tilt Mounting.
J6-222266-15-TMA
6 Point Junction, with four 200 Amp Bushing Well Interfaces and two 600 Amp Bushing Interfaces, 15kV, Tilt Mounting Adapter.
J6-222222-15-TMA
6 Point Junction, with six 200 Amp Bushing Well Interfaces, 15kV, Tilt Mounting Adapter.
J6-222226-25
6 Point Junction, with five 200 Amp Bushing Well Interfaces and one 600 Amp Bushing Interface, 25kV, No Tilt Mounting.
J5-62226-15-N
5 Point Junction, with one 600 Amp Bushing Interfaces, three 200 Amp Bushing Well Interfaces and one 600 Amp Bushing Interfaces, 15kV, No Parking Stand.Frequently Asked Questions
What voltage classes are available for these junctions?
The multipoint junctions are available in 15kV, 25kV, and 35kV voltage classes.
What are the momentary and fault close ratings?
For 600 Amp, the rating is 25kA Sym for 10 Cycles. For 200 Amp, it is 10kA Sym for 10 Cycles.
What interface spacing options are available?
The junctions are available with standard 4'' spacing or an optional 6.5'' spacing.
Do these junctions meet industry standards?
Yes, the junctions meet ANSI/IEEE Standard 386, Latest Revision.
What type of connectors are compatible with these junctions?
These junctions provide mating for Elastimold Elbow connectors, compatible with both 600 Amp and 200 Amp.
What are the continuous current ratings for the junctions?
The continuous current ratings for the junctions are either 600 Amp or 200 Amp.
What is the maximum operating voltage for the 35kV class?
For the 35kV voltage class, the maximum phase-to-ground operating voltage is 21.1kV.
What is the maximum operating voltage for the 25kV class?
For the 25kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV.
What is the maximum operating voltage for the 15kV class?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.
Is there a rule for mixing 200 Amp and 600 Series interfaces?
When a 200 Amp interface is on one side and a 600 Series interface is on the other, always start with the 200 Amp side.
How to Install a Deadbreak Junction with Universal Mount
This guide provides step-by-step instructions for installing a two-, three-, or four-point deadbreak junction (e.g., J2-26-15) using the universal mounting method, including securing brackets, assembling the junction, and grounding the unit.
Estimated time: 1h
Tools needed:
Wrenches (for 3/8 inch and 1/2 inch hex nuts/cap screws), Fastener driver (e.g., screwdriver or drill/driver for mounting fasteners), Wire strippers
Supplies needed:
Deadbreak Junction (J2-26-15), Base Bracket, Base Plate, Universal Brackets (4), Mounting Hardware Prepack (includes various screws, washers, nuts), Suitable fasteners (for attaching universal brackets to mounting surface), Grounding wire (No. 2 solid to 1/0 stranded), ELASTIMOLD approved lubricant, HV insulated caps (for unused bushings)
- Prepare for Installation and Mark Location
Ensure all apparatus is de-energized before beginning installation to prevent serious or fatal injury. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices. Determine the desired location for the junction assembly. Use the base plate as a template, place it on the mounting surface, and mark all four slot locations for the universal brackets.
- Mount Universal Brackets
Secure two universal brackets to the marked slot locations on the flat surface using suitable fasteners. Tighten these fasteners securely to prevent any movement during operation. Attach the remaining two universal brackets to the previously mounted brackets at the desired angle using the supplied 3/8 inch hex head cap screws, external tooth lock washers, and 3/8 inch hex nuts. Tighten securely.
- Assemble and Mount Deadbreak Junction
Assemble the deadbreak junction to the base bracket assembly and base plate. Use two 1/2 inch hex head cap screws, two 1/2 inch split lock washers, and two 1/2 inch hex nuts, attaching them to the center mounting holes on the bracket assembly. Tighten securely. Attach the complete deadbreak junction assembly to the universal brackets using the supplied 1/2 inch hex head cap screws, 1/2 inch split lock washers, and 1/2 inch hex nuts. Ensure the parking stand is in the upright position and tighten all fasteners securely.
- Ground the Assembly
Connect a grounding wire (No. 2 solid to 1/0 stranded) to the grounding lug provided on the base bracket. Ensure the base bracket assembly and the junction's black conductive jacket are properly grounded.
- Prepare for Operation
Remove all protective shipping caps from the operating interfaces and clean them. Lubricate each interface with an ELASTIMOLD approved lubricant; do not substitute, as other lubricants may be harmful. If all operating interfaces are not utilized, install appropriate HV insulated caps on unused bushings before energization. Do not use shipping caps for this purpose, as they are not insulated.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.