ABB Installation Products J2-22-15-SV 2 Point Junction, 15kV, with two 200 Amp Bushing Well Interfaces, 6-1/2 inch centers.
UPC: 783786550579
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV voltage rating for medium-voltage applications
- Two 200 Amp bushing well interfaces for power connections
- 6-1/2 inch center spacing for standard mounting
- ABB Installation Products quality and reliability
- Designed for secure and insulated electrical junctions
Specifications
Application | Suited for Subsurface, Vault or Padmount Applications and can be used for Sectionalizing, Looping, Tapping and Equipment Bypass |
Connection | Push-In |
Material | EPDM-Rubber and Stainless Steel Mounting Brackets |
Mounting | No Tilt Mounting Bracket |
Size | Overall Length 19-1/2 inches, Width 6-3/4 inches |
Special Features | 6-1/2 inch Center Spacing |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Multi-Point Junction - 2 Points |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

J4-6226-15
4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 15kV, No Tilt Mounting.
J4-2222-15-TMA
4 Point Junction, with four 200 Amp Bushing Well Interfaces, 15kV, Tilt Mounting Adapter.
J6-622226-35
6 Point Junction, with one 600 Amp Bushing Interfaces, four 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 35kV, No Tilt Mounting.
J5-22222-15-N
5 Point Junction, with five 200 Amp Bushing Well Interfaces, 15kV, No Parking Stand. Standard 4 inch spacing.
J5-22222-15-SV
5 Point Junction, with five 200 Amp Bushing Well Interfaces, 15kV, 6-1/2 inch centers. No Tilt Mounting.
J3-666-25-SV-R
3 Point Junction, with three 600 Amp Bushing Interfaces, 25kV, 6-1/2 inch centers. Right Parking Stand.
J3-666-25-SV
3 Point Junction, with three 600 Amp Bushing Interfaces, 25kV, 6-1/2 inch centers. No Tilt Mounting.Frequently Asked Questions
Where can these multipoint junctions be installed?
ELASTIMOLD junctions are designed for subsurface, vault, or padmount applications. They feature a fully shielded and fully submersible molded rubber housing.
What items are included in a standard junction kit?
Each kit contains a basic molded junction, mounting hardware, two tubes of lubricant, installation instructions, and a protective cap.
How should 200 Amp and 600 Amp interfaces be ordered?
When a junction has both 200 Amp and 600 Series interfaces, always start with the 200 Amp side when specifying.
What does the Tilt Mounting Adapter (TMA) do?
The TMA bolts to the standard mounting bracket, providing an adjustable angle of 15, 30, 45, or 60 degrees. Two adapters are required for this option.
What interface spacing options are available?
The junctions offer standard 4'' spacing or an optional 6.5'' spacing for interfaces.
Which industry standard does this product meet?
The multipoint junctions meet ANSI/IEEE Standard 386, Latest Revision.
What are the voltage and current ratings of the junction?
The junction is rated for 15kV, 25kV, or 35kV voltage classes. It supports continuous currents of either 200 Amp or 600 Amp.
What materials are used in the junction's construction?
The junction features a molded rubber housing with 100% peroxide-cured insulation and conductive EPDM materials. Brackets utilize 304 stainless steel for corrosion prevention.
What connectors are compatible with these junctions?
These junctions provide mating for Elastimold Elbow connectors, supporting both 600 Amp and 200 Amp types.
What is the maximum operating voltage for a 15kV junction?
For a 15kV junction, the maximum phase-to-ground operating voltage is 8.3kV.
How to Install the J2-Series Deadbreak Junction (Universal Mount)
This guide provides step-by-step instructions for installing the J2-Series deadbreak junction using the universal mount configuration. It covers mounting, assembly, and grounding procedures, along with initial preparation for operation.
Estimated time: 1h
Tools needed:
Wrench, Socket Set, Wire Strippers, Marking Tool, Measuring Tape
Supplies needed:
Deadbreak Junction, Base Bracket, Base Plate, Universal Brackets (4), Mounting Hardware Prepack (3/8" and 1/2" screws, washers, nuts), Suitable Fasteners (user-supplied for surface mounting), Grounding Wire (No. 2 solid to 1/0 stranded), ELASTIMOLD approved lubricant, HV insulated caps (if needed)
- De-energize Apparatus and Prepare Site
DANGER: All apparatus must be de-energized during installation or removal of part(s). This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Ensure all apparatus is de-energized before beginning installation. Determine the desired location for the junction assembly on a flat surface. Use the base plate as a template to mark the slot locations for mounting.
- Mount Universal Brackets
Attach two universal brackets to the marked surface using suitable fasteners (user-supplied). Tighten these fasteners securely to prevent any movement during operation. Then, attach the remaining two universal brackets to the first two at the desired angle using the supplied 3/8" hex head cap screws, external tooth lock washers, and 3/8" hex nuts. Tighten securely.
- Assemble Junction to Base Bracket and Base Plate
Assemble the deadbreak junction to the base bracket assembly and base plate. Secure them together using the supplied two 1/2" hex head cap screws, two 1/2" split lock washers, and two 1/2" hex nuts through the center mounting holes on the bracket assembly. Tighten all hardware securely.
- Attach Junction Assembly to Universal Brackets
Attach the complete deadbreak junction assembly (now with base bracket and base plate) to the previously mounted universal brackets. Use the supplied 1/2" hex head cap screws, 1/2" split lock washers, and 1/2" hex nuts. Tighten securely, ensuring the parking stand is in the upright position.
- Ground the Assembly
Connect a grounding wire (No. 2 solid to 1/0 stranded) to the grounding lug provided on the base bracket. Ensure the base bracket assembly and the junction's black conductive jacket are properly grounded through this connection.
- Prepare Operating Interfaces
Remove all protective shipping caps from the operating interfaces. Clean each interface thoroughly and lubricate them with an ELASTIMOLD approved lubricant. DO NOT substitute other lubricants, as they may harm the product. IMPORTANT: Do not use the protective shipping caps for insulation; they are only for keeping interfaces clean during handling.
- Install Insulated Caps (if applicable)
If any operating interfaces are not utilized, install appropriate HV insulated caps on the unused bushing(s) before energizing the circuit. This is crucial for safety and proper operation. WARNING: Replace shipping covers with appropriate HV insulated caps or connectors before submerging or energizing the circuit.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.