ABB Installation Products CFK 4/0 HSHSS Aluminum Multi-Port Connectors - 95 Series Terminal Kits, Heat Shrink kit, concentric…
UPC: 783786712656
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Aluminum multi-port connector for 4/0 AWG and 250 kcmil conductors
- Includes heat shrink kit for environmental protection
- Utilizes specific die reference 840,324,249,658,TX,76,11A for precise crimping
- Features stainless steel hex-headed bolt hardware for corrosion resistance
- Designed for reliable electrical terminations in industrial applications
Specifications
Application | Multi-port Connector |
Color | Black |
Conductor Range | 4/0 STR AWG , 4/0 COMPR AWG , 250 kcmil |
Connection | Compression |
Insulation | yes |
Material | Aluminum Lug |
Mounting | Allen Head Mounting Bolt |
Special Features | Three Die Sets Install the Complete Range of Lugs from #8 to 350 kcmil. Lugs Prefilled with Oxide-Inhibiting Compound and Capped to Prevent Oxidation and Keep out Moisture. Heat Shrink Tubing |
Type | Flood Seal Multi Port Heat Shrink Fit Connector |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

CFK 4/0 HSH
Aluminum Multi-Port Connectors - 95 Series Terminal Kits, Force Fit Kit, concentric 4/0, compressed 4/0, compact 250, die reference 840,324,249,658,TX,76,11A, Hex Headed Bolt
FSN 2-125 TNAWR
Tin Plated Aluminum Flood-Seal 125 Series Connectors - one-way configuration, two-bolt design with 1.75 Center to Center Spacing, width 3.5 inch, Length 4.625 inch (Not counting Rockets). Outlets 2, includes Screws. Assembled with (2) EPDM Rubber Rockets
FSN 22 AWR
Aluminum Flood-Seal 125 Series Connectors - two-way configuration, two-bolt design with 1.75 inch Center to Center spacing, length 10 inch, Width 3.125 inch. Outlets 4, PVC Coating. Includes Screws. Assembled with Rockets
FSN 22
Aluminum Flood-Seal 125 Series Connectors - two-way configuration, two-bolt design with 1.75 inch Center to Center spacing, length 10 inch, Width 3.125 inch. Outlets 4, PVC Coating. Includes Screws.
FSN 2-125
Aluminum Flood-Seal 125 Series Connectors - one-way configuration, two-bolt design with 1.75 Center to Center Spacing, width 3.5 inch, Length 4.625 inch. Outlets 2, includes Screws.
FSN 4-125
Aluminum Flood-Seal 125 Series Connectors - one-way configuration, two-bolt design with 1.75 inch Center to Center spacing, width 7-1/4 inch, Length 4.625 inch, Outlets 4, Santoprene/EPDM Rubber Coating, includes Screws.
FSN 4-125 AWR
Aluminum Flood-Seal 125 Series Connectors - one-way configuration, two-bolt design with 1.75 inch Center to Center spacing, width 7-1/4 inch, Length 4.625 inch, Outlets 4, Santoprene/EPDM Rubber Coating, includes Screws. Assembled with Rockets
FSN 44
Aluminum Flood-Seal 125 Series Connectors - two-way configuration, two-bolt design with 1.75 inch Center to Center spacing, length 10 inch, Width 6.875 inch. Outlets 8, PVC Coating. Includes Screws.How to Install Thomas & Betts FLOOD-SEAL 95 Heat Shrink Connector Kits
This guide provides detailed instructions for installing Thomas & Betts FLOOD-SEAL 95 Heat Shrink Connector Kits, ensuring a secure and sealed electrical connection for various conductor sizes.
Estimated time: 20m
Tools needed:
Wire brush, Crimping tool, Wrench or socket, Butane torch, Propane torch, 500°F electric heat gun
Supplies needed:
FLOOD-SEAL 95 Heat Shrink Connector Kit (includes heat shrink sleeve and lug), Electrical cable (conductor), Joint compound (if required)
- Ensure Safety and Prepare Conductor
WARNING: Danger of Electric Shock! Ensure power is disconnected. Installation must be performed by trained installers in accordance with all applicable local, state, and national electrical codes, installation standards, and safety rules. Remove the cable insulation to the required length and thoroughly wire brush the conductor to ensure a clean connection surface.
- Position Heat Shrink Sleeve
Slip the heat shrink sleeve over the cable end, ensuring it is positioned far enough back to allow for the lug crimping process without interference.
- Crimp and Secure Lug
Crimp the lug securely onto the conductor end. If using joint compound, wipe away any excess. Bolt the lug firmly to the contact pad on the FLOOD-SEAL connector bus.
- Position Sleeve Over Lug
Slide the heat shrink sleeve forward over the lug until it butts against the connector bus, covering the connection point.
- Shrink Sleeve at Bus End
Apply heat evenly to the sleeve at the bus end using a butane torch, propane torch, or a 500°F electric heat gun. Do not use Acetylene. Continue heating until a bead of mastic appears at the sleeve end, indicating a complete seal.
- Shrink Sleeve Over Terminal Lug
Working away from the connector bus, continue to apply heat evenly to shrink the sleeve over the terminal lug. Move the heat source to a new position as visual shrinkage occurs.
- Shrink Sleeve Over Cable End
Apply heat evenly to shrink the sleeve over the cable end. A seal is complete when a bead of mastic appears at this end. Ensure even heat application and move the heat source as shrinkage occurs.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.