ABB - Installation Products 756LR-P0360-S - 35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400. Cold-Shrinkable Jacket Seal Included.

ABB Installation Products 756LR-P0360-S 35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and…

UPC: 783786799589


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 756LR-P0360-S is a 35kV, 600A deadbreak elbow connector with an integrated test point, designed for reliable medium-voltage cable connections in electrical distribution systems. This fully shielded, submersible elbow meets ANSI/IEEE Standard 386 and is rated for 35kV applications with a maximum phase-to-ground operating voltage of 21.1kV and phase-to-phase voltage of 36.6kV. The connector supports cable insulation diameters from 1.725 inches to 1.935 inches and accommodates compressed stranded conductors up to 650 kcmil, compacted solid conductors up to 750 kcmil, or 400 mm² compact conductors. The deadbreak design enables safe, load-break operations without de-energizing the system, while the integrated test point allows voltage verification without disconnecting the cable. The kit includes an insulated plug, cap, stud, aluminum compression lug, and a cold-shrinkable jacket seal for environmental protection and moisture resistance. The fully molded rubber housing is 100% peroxide-cured, ensuring durability and resistance to environmental stress. This product is ideal for underground residential distribution (URD), pad-mounted transformers, switchgear, and other medium-voltage applications where reliable, maintenance-free connections are critical. The 600 Series designation aligns with ABB’s standardized product line for consistent performance and compatibility across installations. The connector is designed for use with metallic tape shield or drain wire cables, with an ECS cable seal grounding device recommended for optimal performance.
  • 35kV rated, 600A continuous current capacity
  • Supports cable insulation diameters from 1.725" to 1.935"
  • Compatible with compressed stranded (650 kcmil), compacted solid (750 kcmil), or 400 mm² compact conductors
  • Integrated test point for voltage verification without disconnection
  • Fully shielded, submersible molded rubber housing with 100% peroxide-cured construction
  • Includes insulated plug, cap, stud, aluminum compression lug, and cold-shrink jacket seal
  • Meets ANSI/IEEE Standard 386 for medium-voltage applications
  • Designed for underground residential distribution (URD), pad-mounted transformers, and switchgear

Specifications

Amperage Rating
600 A
Application
35 kv, 600 Amp
Color
Black
Conductor Range
650 kcmil , 750 to 800 kcmil
Connection
Compression
Connection Type
Deadbreak Elbow
Environmental Conditions
Fully Submersible
Insulation
True
Material
Aluminum, Cold-Shrinkable Jacket Seal
Material
Housing - EPDM-Rubber
Series
600 Series
Size
Cable Insulation Diameter 1.725 inch to 1.935 inch
Special Features
35kV, 600 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. S - Cold-Shrinkable Jacket Seal
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
35 kV
Width
12.28 in
Width
311.912 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 35kV, Deadbreak, Stick-Op Connector Kit, with Capacitive test point, Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.

756LRTP-P0360

600 Amp, 35kV, Deadbreak, Stick-Op Connector Kit, with Capacitive test point, Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.900 inch to 2.120 inch. Conductor Size AWG or kcmil, Compressed Stranded 1250.

756LR-Q0440

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.900 inch to 2.120 inch. Conductor Size AWG or kcmil, Compressed Stranded 1250.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

756LR-N2330-SG3

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size kcmil Compressed Stranded 450 /Compacted Solid 500/550. Cold-Shrinkable Jacket Seal Included.

756LR-N0320-S

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size kcmil Compressed Stranded 450 /Compacted Solid 500/550. Cold-Shrinkable Jacket Seal Included.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.900 inch to 2.120 inch. Conductor Size AWG or kcmil, Compressed Stranded 1250. Cold-Shrinkable Jacket Seal Included.

756LR-Q0440-S

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.900 inch to 2.120 inch. Conductor Size AWG or kcmil, Compressed Stranded 1250. Cold-Shrinkable Jacket Seal Included.
900 Amp, Elbow Connector, with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, 15/25KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 300 /Compacted Solid 350 /mmSquared Compact 150.

K676LR-M2290

900 Amp, Elbow Connector, with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, 15/25KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 300 /Compacted Solid 350 /mmSquared Compact 150.
900 Amp, Elbow Connector, with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, 15/25KV, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.

K676LR-N2400

900 Amp, Elbow Connector, with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, 15/25KV, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.
900 Amp, 35kV, 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.

775LR-J2260

900 Amp, 35kV, 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.

Frequently Asked Questions

What is the primary application of the 756LR?

The 756LR provides fully shielded, dead-front submersible cable connections to high-voltage apparatus.

What cable insulation diameters are supported?

The 756LR supports cable insulation diameters from 0.760 inches to 2.120 inches.

What is the maximum phase-to-phase voltage?

The maximum phase-to-phase voltage for the 35kV class is 36.6kV.

What standards does the 756LR meet?

The 756LR meets ANSI/IEEE Standard 386, Latest Revision.

Is the 756LR suitable for submersible applications?

Yes, it features a fully shielded, fully submersible molded rubber housing.

What is the impulse withstand rating (BIL)?

The impulse withstand (BIL) rating is 150kV (1.2 x 50 microsecond wave).

What is the continuous current rating of the elbow?

The elbow connector has a continuous current rating of 600 Amps.

What conductor sizes are compatible with the 756LR?

It is compatible with #2 AWG to 1250 kcmil for aluminum and copper conductors.

What is the maximum voltage rating for the 756LR?

It is rated for 35kV voltage class, with a maximum phase-to-ground operating voltage of 21.1kV.

What is the AC one-minute withstand voltage?

The AC one-minute withstand voltage rating is 50kV.

How to Install 756LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and initial setup of 756LR Deadbreak Elbow Connectors on 35kV class systems, including cable preparation, component assembly, and grounding procedures.

Estimated time: 1h 30m

Tools needed:

Crimping tool, Wire strippers, Wire brush, Torque wrench, Hotstick, Suitable voltage sensing device

Supplies needed:

756LR Elbow, Cable Adapter, Compression Lug, Insulating Plug (if applicable), Crimp connector, Lubricant, Threaded Stud (if mating part not equipped), Grounding wire (min. No. 14 AWG Copper equivalent), Suitable grounding connector, Waterproofing material (for cable jacket)

  1. Ensure Safety and Position Cable

    DANGER: De-energize all apparatus before installation or removal. Do not touch or move energized products. Position the cable in its final assembled position with enough slack to allow for elbow removal. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product.

  2. Clean Cable Outer Jacket

    Clean the outer jacket of the cable for a distance of 24 inches (610mm) from the cut end.

  3. Prepare Cable End

    Follow the specific cable preparation instructions for your cable type (e.g., UNISHIELD, LEAD SHEATH, Jacketed, Non-Jacketed). This typically involves removing the outer jacket (if applicable) and preparing the cable insulation and semi-con shield to specific dimensions as shown in the product's detailed diagrams. Refer to instructions supplied with any grounding devices or cable shield adapters if used.

  4. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  5. Prepare Conductor Length

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Ensure not to cut or nick the cable adapter or the conductor. The exposed conductor length must be between 4-3/8 inches to 4-3/4 inches (111mm-121mm). If not, redo the assembly.

  6. Crimp Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it. Measure the 'Check Dimension' (must be less than 7 inches / 178mm) before crimping. Crimp the compression lug according to the instructions supplied with the lug. Wipe all excess inhibitor from the lug and cable adapter. After crimping, the distance from the end of the lug to the cable adapter should be between 6-7/8 inches to 7-5/8 inches (175mm-194mm). If not, redo the assembly.

  7. Install Elbow onto Cable Adapter

    Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Verify the cable adapter is still flush with the tape marker; reposition if necessary. Remove the tape marker.

  8. Prepare Mating Products for Connection

    Remove protective caps from both the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud supplied with the elbow into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean.

  9. Connect Elbow to Mating Part

    Push the elbow onto the mating part, carefully lining up the hole in the compression lug with the stud on the mating part. DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED.

  10. Connect Opposite End Mating Part (if applicable)

    Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to the instructions supplied with that specific mating part.

  11. Install Insulating Plug and Voltage Detection Cap (if used)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down hard until it snaps into place. CAUTION: The insulating plug provides a means for detecting system voltage; follow voltage test directions carefully.

  12. Ground the Cable Shield

    Insert one end of a grounding wire (with ampacity at least equivalent to No. 14 AWG Copper) through the grounding eye and twist to make a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded; follow instructions supplied with any grounding device or use an alternate method. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  13. Perform Voltage Test (Optional but Recommended)

    If the connector is equipped with an integral capacitance test point, remove the test point cap with a hotstick by peeling it off at an angle. WARNING: This is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points and follow its manufacturer's directions. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means, as contamination or incorrect equipment can give false readings. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.