ABB - Installation Products 756LR-M0320 - 35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.

ABB Installation Products 756LR-M0320 35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and…

UPC: 783786463008


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 756LR-M0320 is a 35kV, 600 Amp Deadbreak Elbow Connector designed for fully shielded, dead-front submersible cable connections to high-voltage apparatus. This elbow meets ANSI/IEEE Standard 386 and is rated for 21.1kV maximum phase-to-ground operating voltage and 36.6kV maximum phase-to-phase. It offers 150kV BIL impulse withstand and a 50kV AC one-minute withstand rating. The 756LR features a 100% peroxide-cured molded rubber housing constructed from insulation and conductive EPDM materials, ensuring full shielding and submersible capability. This deadbreak elbow is designed for use with cable insulation diameters ranging from 0.760 inches to 2.120 inches, with this specific model (756LR-M0320) accommodating 1.370 to 1.630 inches. It supports conductor sizes from #2 AWG to 1250 kcmil for both aluminum and copper conductors. The kit includes a copper compression lug, stud, insulated plug with cap, lubricant tubes, cable adapter, and installation instructions. The integrated test point allows for safe voltage verification without cable disconnection. Connections and disconnections can be performed using standard hand tools and equipment in a de-energized state. Optional accessories are available for visible external separation, by-pass, isolation, dead-ending, grounding, testing, and adding taps, surge arrestors, or fault current indicators. When used on metallic tape shield or drain wire cable, an ECS cable seal grounding device is recommended. SKU: 756LR-M0320.
  • Fully rated 35kV, 600 Amp Deadbreak Elbow Connector
  • Fully shielded, fully submersible molded rubber housing
  • 100% peroxide-cured construction with insulation and conductive EPDM materials
  • Accommodates cable insulation diameters from 1.370" to 1.630"
  • Integrated test point for safe voltage verification

Specifications

Amperage Rating
600 A
Application
35 kv, 600 Amp
Color
Black
Conductor Range
450 kcmil , 500 to 550 kcmil
Connection
Compression
Connection Type
Compression Lug
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Material
Aluminum
Series
600 Series
Size
Cable Insulation Diameter 1.370 inch to 1.630 inch
Special Features
35kV, 600 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
35 kV
Voltage Rating
35kV
Width
12.28 in
Width
311.912 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
8.6000 L
Package Weight (Metric)
3.9010 kg
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.

755LR-N0320

600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

756LR-J0250-SG3

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

756LR-L2320-SG3

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

756LR-L2330-SG3

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

756LR-L0270

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

756LR-L2300-SG3

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
600 Amp, 35KV, DeadBreak, Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

756LR-K0270

600 Amp, 35KV, DeadBreak, Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

Frequently Asked Questions

What voltage rating does the 756LR-M0320 support?

The 756LR-M0320 is rated for 35kV medium-voltage applications.

What cable insulation diameters are compatible?

The elbow accommodates cable insulation diameters from 1.370 inch to 1.630 inch.

Does the 756LR-M0320 include a test point?

Yes, the deadbreak elbow features a built-in test point for safe voltage verification.

What material is the lug made from?

The compression lug is made from aluminum for secure conductivity and mechanical strength.

What conductor sizes does this elbow support?

It supports conductor sizes of 450 AWG, 500 kcmil, and 550 kcmil (compressed stranded or compacted solid).

Is the 756LR-M0320 part of a specific ABB series?

Yes, it is part of ABB’s 600 Series of deadbreak products for medium-voltage applications.

How to Install 756LR/776LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and connection of 756LR and 776LR deadbreak elbow connectors on 35kV class systems. DANGER: All apparatus must be de-energized during installation or removal of parts to prevent serious or fatal injury.

Estimated time: 2h

Tools needed:

Wire strippers, Crimping tool, Wire brush, Hotstick, Voltage sensing device (for capacitive test points), Torque wrench

Supplies needed:

Elbow connector (756LR or 776LR), Cable adapter, Compression lug, Insulating plug, Lubricant (supplied with kit), Threaded stud (supplied with kit), Cable (appropriate for 35kV class systems), Tape marker, No. 14 AWG Copper wire (or equivalent), Suitable grounding connector, Silicone lubricant, HV insulated cap(s) or connector(s), Mating apparatus or bushing

  1. Prepare for Installation and Inspect Parts

    Ensure all apparatus is de-energized. Inspect all parts for damage, proper rating, and compatibility with mating components. If the product includes protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before energizing or submerging the circuit. Read all instructions and have required tools ready.

  2. Position and Cut Cable

    Position the cable in its final assembled location, ensuring enough slack for elbow removal. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product.

  3. Clean Cable Outer Jacket

    Clean the outer jacket of the cable for a distance of 24 inches (610mm).

  4. Prepare Cable for Adapter

    Follow the specific cable preparation instructions (A, B, or C) that apply to your cable type (e.g., non-jacketed concentric neutral, jacketed shield wires, etc.). Remove the outer jacket (if applicable) and prepare the cable to expose the insulation, semi-con shield, and neutral/shield wires to the specified lengths using a tape marker.

  5. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  6. Prepare Conductor Length

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The exposed conductor length must be between 4-3/8 inches to 4-3/4 inches (111mm-121mm). If not, redo the assembly.

  7. Crimp Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it. Measure the 'Check Dimension' before crimping (must be less than 7 inches/178mm). Crimp the compression lug according to its supplied instructions. Wipe all excess inhibitor from the lug and cable adapter surface after crimping. The distance from the end of the lug to the cable adapter must be between 6-7/8 inches to 7-5/8 inches (175mm-194mm). If not, redo the assembly.

  8. Install Elbow onto Cable Adapter

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  9. Prepare and Connect Mating Products

    WARNING: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove protective caps from both the elbow and the mating part. If the mating part lacks a stud, hand tighten the threaded stud supplied with the elbow into it. Clean and lubricate both the elbow and the mating part with the supplied lubricant, keeping surfaces clean. Push the elbow onto the mating part, aligning the compression lug hole with the stud.

  10. Insert Opposite Mating Part

    Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to its supplied instructions. CAUTION: When constructing 600amp L-Kits, tighten each component to specified torque per plug connector instructions.

  11. Install Insulating Plug or Voltage Detection Cap

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap and place it on the elbow. Push down hard until the cap snaps into place. CAUTION: The insulating plug provides a means for detecting system voltage.

  12. Ground the Cable Shield

    Insert one end of a wire (at least No. 14 AWG Copper ampacity) through the grounding eye and twist to form a small loop, ensuring not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded according to instructions supplied with a grounding device, or via an alternate method if no device is used. Waterproof the cable jacket at this point to prevent moisture ingress.

  13. Perform Voltage Test (Post-Installation)

    To test for voltage, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device made for capacitive test points and follow its manufacturer's directions. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means, as contamination or wrong equipment can give false readings. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.