ABB - Installation Products 756LR-H0270-200 - 35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed Stranded 4/0 AWG or Compacted Solid 250 kcmil. 200kv BIL.

ABB Installation Products 756LR-H0270-200 35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and…

UPC: 075114214919


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 756LR-H0270-200 is a 35kV 600 Amp Deadbreak Elbow connector designed for fully shielded, dead-front submersible cable connections to high-voltage apparatus. This elbow meets ANSI/IEEE Standard 386 and is rated for 21.1kV maximum phase-to-ground operating voltage and 36.6kV maximum phase-to-phase. It features a 150kV BIL (Basic Impulse Level) rating for impulse withstand and a 50kV AC one-minute withstand rating. The connector is designed for continuous operation at 600 Amps and can handle a 25kA symmetrical momentary current for 10 cycles. The molded rubber housing is constructed from 100% peroxide-cured EPDM insulation and conductive materials, providing a fully shielded and submersible interface. This deadbreak elbow is suitable for conductor sizes ranging from 4/0 AWG compressed stranded aluminum to 250 kcmil compacted solid aluminum, with cable insulation diameters from 0.850 inches to 1.050 inches. The kit includes an aluminum compression lug, a test point for diagnostic capabilities, an insulated plug with cap, a stud, a cable adapter, and lubricant. Optional accessories are available for various functions including visible external separation, by-pass, isolation, dead-ending, grounding, and testing. The ABB 756LR-H0270-200 is ideal for applications in substations, industrial facilities, and utility distribution networks requiring reliable, dead-front connections. SKU: 756LR-H0270-200.
  • Fully rated 35kV, 600 Amp Deadbreak Elbow connector
  • Fully shielded, fully submersible molded rubber housing
  • 150kV BIL Impulse Withstand, 50kV AC One Minute Withstand
  • Suitable for 0.850" to 1.050" cable insulation diameters
  • Accommodates 4/0 AWG compressed stranded or 250 kcmil compacted solid aluminum conductors

Specifications

Amperage Rating
600 A
Application
35 kv, 600 Amp
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection
Compression
Connection Type
Compression Lug
Environmental Conditions
Fully Submersible
Insulation
True
Material
Aluminum
Material
Housing - EPDM-Rubber
Series
600 Series
Size
Cable Insulation Diameter 0.850 inch to 1.050 inch
Special Features
35kV, 600 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
35 kV
Width
12.28 in
Width
311.912 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

756LR-L2270-SG3

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch (24.892-29.972mm). Aluminum Compression Lug, Conductor Size 300 Stranded/Compressed or 350 Solid/Compact or 150 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

K465LR-J0290

15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch (24.892-29.972mm). Aluminum Compression Lug, Conductor Size 300 Stranded/Compressed or 350 Solid/Compact or 150 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.850-1.050 inches (21.590-26.670mm). Compression Lug, Conductor Size 120 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

K465LR-H-120MMSQ

15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.850-1.050 inches (21.590-26.670mm). Compression Lug, Conductor Size 120 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch (24.892-29.972mm). Compression Lug, Conductor Size 185 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

K465LR-J-185MMSQ

15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch (24.892-29.972mm). Compression Lug, Conductor Size 185 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch (27.686-33.274mm). Compression Lug, Conductor Size 240 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

K465LR-K-240MMSQ

15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch (27.686-33.274mm). Compression Lug, Conductor Size 240 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch (24.892-29.972mm). Copper Compression Lug, Conductor Size 4/0 Stranded/Compressed or 250 Solid/Compact or 125 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

K465LR-J-2270

15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch (24.892-29.972mm). Copper Compression Lug, Conductor Size 4/0 Stranded/Compressed or 250 Solid/Compact or 125 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 1.280 inch to 1.430 inch (29.972-37.211mm). Compression Lug, Conductor Size 400 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

K465LR-LM-400MMSQ

15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 1.280 inch to 1.430 inch (29.972-37.211mm). Compression Lug, Conductor Size 400 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000.

756LR-P0410

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000.

Frequently Asked Questions

What is the primary application of the 756LR elbow?

The 756LR provides fully shielded, dead-front submersible cable connections to high-voltage apparatus.

Is the 756LR elbow submersible?

Yes, it features a fully shielded, fully submersible molded rubber housing.

What is recommended for metallic tape shield cables?

An ECS cable seal grounding device is recommended when using the 756LR on metallic tape shield or drain wire cable.

What is the momentary current withstand rating?

It can withstand 25kA Symmetrical for 10 cycles momentarily.

What is the impulse withstand (BIL) rating?

The impulse withstand (BIL) rating is 150kV (1.2 x 50 microsecond wave).

What materials are used in the elbow's construction?

It is constructed with 100% peroxide-cured insulation and conductive EPDM materials.

Does the product meet any industry standards?

Yes, the product meets ANSI/IEEE Standard 386, Latest Revision.

What is the continuous current rating of the elbow?

The elbow connector has a continuous current rating of 600 Amp.

What cable insulation diameters does the 756LR support?

The 756LR supports cable insulation diameters ranging from 0.760 inches to 2.120 inches.

What conductor sizes are compatible with the 756LR?

It is compatible with #2 AWG to 1250 kcmil for aluminum and copper conductors.

How to Install 756LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 756LR Deadbreak Elbow Connectors, including cable preparation, component assembly, and grounding procedures for 35kV class systems.

Estimated time: 2h

Tools needed:

Wire strippers, Crimping tool, Wire brush, Hotstick, Voltage sensing device, Torque wrench

Supplies needed:

756LR Deadbreak Elbow Connector, Cable Adapter, Compression Lug, Insulating Plug, Lubricant, Threaded Stud, Grounding wire (min. 14 AWG Copper), Grounding connector, Cable jacket waterproofing material, Silicone lubricant

  1. De-energize and Inspect Apparatus

    Ensure all apparatus in the work area are de-energized during installation or removal of parts. Do not touch or move energized products. Inspect all parts for damage, correct rating, and compatibility with mating parts before proceeding.

  2. Position and Cut Cable

    Position the cable so it is located in its final assembled position, ensuring enough slack to provide adequate clearance for removing the elbows. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product.

  3. Clean Cable Outer Jacket

    Clean the outer jacket of the cable for a distance of 24 inches (610mm) from the cut end to prepare for subsequent steps.

  4. Prepare Cable Insulation and Shield

    Following the appropriate method for your specific cable type (e.g., non-jacketed concentric neutral, jacketed shield wires, flat metallic tape shield, fabric tape shield, or longitudinally corrugated shield), remove the outer jacket and prepare the cable to the specified dimensions for insulation, semi-con shield, and neutral wires/shield tapes. Refer to the provided diagrams for precise measurements and binding locations.

  5. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean the cable insulation, then lubricate it, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  6. Prepare Conductor Length

    Remove any protruding cable insulation by cutting it even with the end of the cable adapter. Exercise caution to avoid cutting or nicking the cable adapter or the conductor. Verify that the exposed conductor length is between 4-3/8 inches to 4-3/4 inches (111mm-121mm). If the length is outside this range, redo the assembly.

  7. Crimp Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the compression lug. Measure the 'Check Dimension' before crimping; this dimension should be less than 7 inches (178mm). Crimp the compression lug following the crimping instructions supplied with the lug. After crimping, wipe all excess inhibitor from the compression lug and cable adapter surface. The distance from the end of the compression lug to the cable adapter should be between 6-7/8 inches to 7-5/8 inches (175mm-194mm).

  8. Install Elbow onto Cable Adapter

    Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  9. Prepare and Connect Mating Products

    Remove protective caps from both the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud supplied with the elbow into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean. Push the elbow onto the mating part, carefully lining up the hole in the compression lug with the stud on the mating part.

  10. Connect Opposite End of Elbow

    Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to the specific instructions provided with that mating part. For 600-ampere L-Kits, ensure each component is tightened to the specified torque.

  11. Install Insulating Plug (if applicable)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down firmly until it snaps into place. This plug provides a means for detecting system voltage.

  12. Ground the Cable Shield

    Insert one end of a grounding wire (with ampacity at least equivalent to No. 14 AWG Copper) through the grounding eye and twist to form a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded, either via a grounding device or an alternate method. It is also recommended to waterproof the cable jacket at this point to prevent moisture from entering the cable.

  13. Perform Voltage Test (Post-Installation)

    If the connector is equipped with an integral capacitance test point, remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Use a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. Do not use conventional voltage measuring equipment. After voltage detection, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.