ABB Installation Products 750ETP-375ESA30 35kV 600 Series Deadbreak, Loadbreak Elbow Tap Plug, with elbow arresters.
UPC: 783786668915
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 35kV rated for single-phase applications with 21.1kV phase-to-ground and 36.6kV phase-to-phase operating voltage
- 200A loadbreak and 600A continuous current ratings with 150kV BIL impulse withstand
- Integrated elbow arresters provide overvoltage protection for connected equipment
- Compatible with 375DRG, 376DRG, 375ESA-XX, 375LR, and 370GLR mating connectors
- Peroxide-cured insulation and jacket for durability in harsh utility environments
Specifications
Amperage Rating | 600 A |
Application | 600 Amps, 35kV |
Color | Black |
Connection | Compression |
Current Rating | 600 A |
Insulation | EPDM Rubber |
Material | Housing - EPDM-Rubber |
Series | 600 Series |
Size | 600 Series |
Special Features | Includes Sealing Kit |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Window-Op Connector |
Voltage Rating | 35kV |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

3701A4
35kV 200 Amp, Loadbreak Bushing Insert, rated for single phase applications only. Includes a black vent ring.
K655VSL2-MAC04
15/25kV, 600 Amps, 2-Way Vault-Stretcher with Shear Bolts. Cable Insulation Diameter range 1.37-1.63 inch (34.8-41.4mm). Connector Sizing AC04 - 750-1250 kcmil Stranded, Compressed, Solid or Compact. Kit Includes (1) Vault Stretcher Housing, (2) Aluminum Shear Bolts, (2) Cable Adapters and (2) Insulated Plugs with Caps and (1) Stud.
151-GP
15/25kV 200 Amp, Deadbreak Grounding Plug, Bails are required, but not included, order separately.
1601DLA
15kV, 200 Amp, DeadBreak to LoadBreak Bushing Adapter, Red. Includes hex-broach for Torque installation, Peroxide-cured insulation and jacket, Provision for ground wire connection, All copper current path. Red PBT interface shield reduces sticking and provides seating indicator.
K656DLR-K0300
600 Amp, 15/25kV, 600 Series Deadbreak Direct Test Elbow with Test Point, (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size kcmil Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.Frequently Asked Questions
How do I order the 750ETP with a loose stud?
To order with a loose stud, add the suffix "S" to the part number.
How do I order the 750ETP with a factory-assembled stud?
To order with a factory-assembled stud, add "SP" to the part number.
What items are included in the 750ETP kit?
The kit includes the 750ETP plug, a protective shipping cap, two lubricants, and installation instructions.
Is the loadbreak interface designed for energized operation?
Yes, the loadbreak interface is designed for energized operation.
What is the continuous and loadbreak current rating?
The continuous and loadbreak current rating for the tap is 200 Amp.
What is the impulse withstand (BIL) rating?
The impulse withstand (BIL) rating is 150kV (1.2 x 50 microsecond wave).
What is the maximum phase-to-phase voltage?
The maximum phase-to-phase voltage for the 750ETP is 36.6kV.
What is the maximum phase-to-ground operating voltage?
The maximum phase-to-ground operating voltage for the 750ETP is 21.1kV.
What is the voltage class and phase rating?
The 750ETP is rated for 35kV voltage class and single phase (1Ø) applications only.
What products are compatible with the 750ETP?
The 750ETP mates with 375DRG, 376DRG, 375ESA-XX, 375LR, and 370GLR products.
How to Install the LINK-C Deadbreak Cam Link Operable Connector System
This guide provides detailed instructions for the safe installation and initial setup of the LINK-C 600 amp deadbreak cam link operable connector system, including mounting, wiring, and grounding procedures.
Estimated time: 2h
Tools needed:
Hot stick, 600ATM Operating Tool, Torque wrench (with 1 inch hex socket), Welding equipment (if applicable), Multimeter or 370TR Test Rod, Wire strippers
Supplies needed:
ELASTIMOLD supplied lubricant, 3/8-16 x 2 inch long studs (if applicable), Hex nuts (3/8-16), Lockwashers (3/8-16), #14 AWG or #12 AWG solid copper wire, Appropriate grounding connectors, HV insulated caps or connectors (if replacing shipping covers)
- Prepare for Installation and Ensure Safety
Read all installation instructions thoroughly before starting. DANGER: De-energize all apparatus during installation or removal of parts. Inspect all components for damage, proper rating, and compatibility with mating parts. If the product is supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit. Have all required tools at hand and maintain cleanliness throughout the procedure.
- Install the 600 Amp Elbow
Install the 600 amp elbow onto the cable according to the specific installation instructions supplied with the elbow. Ensure that the elbow will align correctly with the stand-off plug or apparatus bushing.
- Mount the Stand-Off Plug (If Applicable)
Weld three 3/8-16 x 2 inch long studs to the equipment faceplate per customer standard practice. Install three hex nuts onto the studs to support the stand-off plug, ensuring it is in-line with the apparatus bushing. Install the stand-off plug over the three studs, resting on the nuts or optional spacers. Install a lockwasher and hex nut on each of the three studs and tighten to 12 ft-lbs torque. Verify that the top surfaces of the apparatus bushing and stand-off plug are in-line; readjust the nuts as required.
- Install Bushing Extender and Elbow
Clean and thoroughly lubricate the apparatus bushing and both interfaces of the 600 amp bushing extender with ELASTIMOLD supplied lubricant. Install the bushing extender onto the apparatus bushing. Insert the 600ATM into the retainer contact, engage its internal hex broach, and thread the retainer contact into the apparatus bushing using a suitable tool applied to the 1 inch hex portion of the 600ATM; torque to 50-60 ft-lbs. Clean and thoroughly lubricate the epoxy standoff plug and both interfaces of the 600 amp elbow with ELASTIMOLD supplied lubricant. Install the elbow onto the epoxy standoff plug. Insert the 600AMT into the retainer contact, engage its internal hex broach, and thread the retainer contact into the epoxy standoff plug through the hole in the compression lug; torque to 50-60 ft-lbs.
- Install the Alignment Bracket
Remove the bushing extender clamp and elbow clamp from the alignment bracket. Position the alignment bracket on the bushing extender to a dimension of 2.5 inches (63.5mm) from the grounding eye. Assemble the bushing extender clamp to the alignment bracket with the supplied hardware, torquing by alternating sides until the clamp tabs are flush with each other and tight on both sides.
- Position and Secure the Elbow
Position the elbow in the alignment bracket such that the elbow cuff is lined up evenly with the bushing extender cuff. Assemble the elbow clamp to the alignment bracket with the supplied hardware, torquing by alternating sides until the clamp tabs are flush with each other and tight on both sides. Ensure the elbow clamp notch faces the cable entrance of the elbow.
- Insert the Link
Clean and thoroughly lubricate both 600 ampere interfaces of the Link with ELASTIMOLD supplied lubricant. Align the Link such that when inserted into the bushing extender and elbow, the Link is perpendicular to the switch faceplate. Insert the Link into the bushing extender and elbow, making sure both lever arms are on the inside of the alignment bracket legs. Engage the pivot pin into the slots in the alignment bracket legs. While pushing inward, move the lever arms downward using a hot stick eye, thus engaging the roller pin and moving the Link inward. Continue moving lever arms until perpendicular to the alignment bracket leg.
- Ground the System
Ground the elbow by feeding a #14 AWG or #12 AWG solid copper wire through the grounding eye on the elbow, twisting it tight, and connecting it to ground. Clean and lubricate the 200 amp interface on the Link. Ground, then install the desired mating product on the 200 amp interface per its installation instructions. Ground the cable: if concentric neutral cable is used, twist the concentric neutral wires together and connect to ground using an appropriate connector; if 20MA or 21MA grounding devices are used, connect the ground lead from the device to ground using a suitable connector. For three-phase installations, tie all grounds from all three phases to a common ground point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.