ABB - Installation Products 69TCJS45B57P55VLNNB - 69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 5, Connector type Copper/no connector required. Connector Code 57P - Conductor Diameter Range - 1.942-2.017 inch (49.33-51.23mm), Heatsink Size 55 - Outside Diameter 3.000 inch, Heatsink Bore - V - 2.046 inch. Type Shield - L - Lead and Neutral Wire, Metallic Screen Continuity Kit - N - mpt required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink standard package
ABB - Installation Products

69TCJS45B57P55VLNNB

UPC: 783786555987


Documents & Media
Specification SheetManufacturer Product Website

Contact for Pricing

Overview

This ABB Installation Products 69 kV Transmission Cable Joint, SKU 69TCJS45B57P55VLNNB, is engineered for robust electrical connections in high-voltage transmission networks. Featuring a Shieldbreak housing type with Housing Style 4 and Housing Size 5, this joint ensures reliable performance. The integrated heatsink, sized at 55 with an outside diameter of 3.000 inches and a bore of 2.046 inches, is designed for effective thermal management. This model requires no external connector, simplifying installation and reducing potential points of failure. It is specifically designed for conductors with a diameter range of 1.942-2.017 inches (49.33-51.23mm). The joint includes a Lead and Neutral Wire shield type (Type Shield - L) and a Metallic Screen Continuity Kit (N - not required), indicating a self-contained continuity solution. The Outer Jacket Restoration Kit is a standard Heat Shrink package (B). This product is suitable for applications demanding secure and efficient 69 kV cable terminations where conductor size falls within the specified range and metallic screen continuity is not an external requirement. The copper material ensures excellent conductivity and durability for critical power infrastructure. Key Specifications: * **Voltage Rating:** 69 kV * **Housing Type:** Shieldbreak, Housing Style 4, Housing Size 5 * **Heatsink Dimensions:** Size 55, Outside Diameter 3.000 inch, Bore 2.046 inch * **Conductor Diameter Range:** 1.942-2.017 inch (49.33-51.23mm) * **Connector Type:** No connector required * **Shield Type:** Lead and Neutral Wire (L) * **Metallic Screen Continuity:** Not required (N) * **Outer Jacket Restoration:** Heat Shrink standard package (B) * **Manufacturer:** ABB - Installation Products * **SKU:** 69TCJS45B57P55VLNNB
  • 69 kV voltage rating for high-voltage transmission applications.
  • Shieldbreak housing type (Style 4, Size 5) for secure cable termination.
  • Heatsink Size 55 with 3.000" OD and 2.046" bore for effective thermal management.
  • Designed for conductors ranging from 1.942 to 2.017 inches (49.33-51.23mm).
  • No external connector required, simplifying installation.

Specifications

Application
For use on Solid Dielectric Cables - providing permanent, fully-shielded, fully submersible cable joints for direct burial or vault applications
Color
Black
Conductor Range
1.942 to 2.017 in
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Special Features
Each Cable Joint is produced exactly to design, producing a quality not possible with field molding equipment or tape. Electrically tested in the factory to ensure consistent quality. Molding is done in the factory, reducing on-site time - no penciling of cable installation required. Easy to learn installation procedure. Field molds, wrapping machines or pre-stretch not required, and a low-cost assembly tool is available. Extended shelf life enables instant availability of spares. Designed with optimized pre-molded stress control and heat transfer capabilities
Standard
ANSI C119.4, Shield Test IEEE 592
Temperature Rating, Maximum
194 F
Temperature Rating, Maximum
90 C
Temperature Rating, Minimum
194 F
Temperature Rating, Minimum
90 C
Type
Transmission Cable Joint - Shieldbreak
Voltage Rating
69 kV
Package Dimensions (L x W x H)
1 IN x 1 IN x 1 IN
Package Dimensions (L x W x H)
2.54 cm x 2.54 cm x 2.54 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 4. Housing Size 5.

69TCJS4-5-4

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 4. Housing Size 5.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 500.

25PCJ2N2410-N2330

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 500.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.

35PCJ1Q1380

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

15PCJ1G1220

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 350. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

25PCJ2L1300-H1240

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 350. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

15PCJ1H1250

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

15PCJ1L1330

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 750. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Stranded 500.

25PCJ2N2380-M2330

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 750. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Stranded 500.

Frequently Asked Questions

What voltage systems are TCJ joints designed for?

TCJ transmission cable joints are designed for 46 kV through 138 kV class systems.

What cable types are compatible with TCJ joints?

TCJ transmission cable joints are designed for use on solid dielectric cables.

What cable insulation diameters do TCJ joints support?

For Style 1 (through 69 kV), insulation diameters range from 1.43 inches to 2.58 inches. For Style 4 (through 138 kV), they range from 2.25 inches to 3.62 inches.

What are the applications for TCJ transmission cable joints?

When assembled, these joints provide permanent, fully shielded, fully submersible cable joints suitable for direct-burial or vault applications.

What is the maximum continuous conductor temperature?

The maximum continuous conductor temperature for TCJ transmission cable joints is 90 °C.

What is the maximum system voltage for 69 kV class joints?

The maximum system voltage for 69 kV class TCJ joints is 72.5 kV.

What is the maximum system voltage for 138 kV class joints?

The maximum system voltage for 138 kV class TCJ joints is 145 kV.

What is the BIL rating for 69 kV class joints?

The Basic Impulse Level (BIL) rating for 69 kV class joints is 350 kV (1.2 x 50μs; 10 positive, 10 negative impulses).

What is the BIL rating for 138 kV class joints?

The Basic Impulse Level (BIL) rating for 138 kV class joints is 650 kV (1.2 x 50μs; 10 positive, 10 negative impulses).

Are field molds or tape wrapping required for installation?

No, field molds, wrapping machines, or pre-stretch are not required for installation. The easy-to-learn procedure eliminates these needs.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.