ABB - Installation Products 69TCJS44B54P4SLFNB - 69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4, Connector type Copper/no connector required, Connector Code 54P - Conductor Diameter Range - 1.648-1.746 inch (41.86-44.35mm), Heatsink Size 4 - Outside Diameter 2.500 inch, Heatsink Bore - S - 1.750 inch. Type Shield - L - Lead and Neutral Wire, Metallic Screen Continuity Kit - F - 4/0 Bonding Cable 6 foot quantity 6 with Split Bolts Quantity 12, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink standard package
ABB - Installation Products

69TCJS44B54P4SLFNB

UPC: 783786514571


Documents & Media
Specification SheetManufacturer Product Website

Contact for Pricing

Overview

This ABB 69 kV Transmission Cable Joint (SKU: 69TCJS44B54P4SLFNB) is designed for shieldbreak applications, featuring Housing Style 4 and Housing Size 4. It accommodates conductors with a diameter range of 1.648 to 1.746 inches (41.86-44.35mm). The joint requires no separate connector, simplifying installation. The integrated heatsink, Size 4 with an outside diameter of 2.500 inches and a bore of 1.750 inches (Heatsink Bore - S), is crucial for thermal management in high-voltage transmission systems. The shield type is L, indicating lead and neutral wire compatibility. Metallic screen continuity is provided by a kit including a 4/0 bonding cable (6-foot length, quantity 6) and split bolts (quantity 12). An armor kit is not required for this configuration. The outer jacket restoration is handled by a standard heat shrink package (Type B). This component is essential for reliable and safe connections in 69 kV power transmission networks, ensuring proper electrical continuity and thermal dissipation under operational loads. UNSPSC Code: 39121452.
  • 69 kV Transmission Cable Joint for Shieldbreak Applications
  • Housing Style 4, Housing Size 4
  • Conductor Diameter Range: 1.648-1.746 inch (41.86-44.35mm)
  • Integrated Heatsink (Size 4, 2.500" OD, 1.750" Bore)
  • Includes Lead/Neutral Wire Shield, Metallic Screen Continuity Kit, and Heat Shrink Jacket Restoration

Specifications

Application
For use on Solid Dielectric Cables - providing permanent, fully-shielded, fully submersible cable joints for direct burial or vault applications
Color
Black
Conductor Range
1.648 to 1.746 in
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Special Features
Each Cable Joint is produced exactly to design, producing a quality not possible with field molding equipment or tape. Electrically tested in the factory to ensure consistent quality. Molding is done in the factory, reducing on-site time - no penciling of cable installation required. Easy to learn installation procedure. Field molds, wrapping machines or pre-stretch not required, and a low-cost assembly tool is available. Extended shelf life enables instant availability of spares. Designed with optimized pre-molded stress control and heat transfer capabilities
Standard
ANSI C119.4, Shield Test IEEE 592
Temperature Rating, Maximum
194 F
Temperature Rating, Maximum
90 C
Temperature Rating, Minimum
194 F
Temperature Rating, Minimum
90 C
Type
Transmission Cable Joint - Shieldbreak
Voltage Rating
69 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
64.2000 L
Package Weight (Metric)
29.1210 kg
69kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4 - Bore Diameter 2.250 inch, Insulation Range 2.565-2.948 inch, Connector Type - Copper/No Connector Required, Conductor Code 54P - 1.648-1.746 inch Diameter, Heatsink Size 4 - 2.500 inch Outside Diameter, Heatsink Bore Diameter S - 1.750 inch, Type Shield L - Lead and Neutral Wire, Metallic Screen Continuity Kit Not Required, Armour Kit Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.

69TCJS44B54P45SLNNB

69kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4 - Bore Diameter 2.250 inch, Insulation Range 2.565-2.948 inch, Connector Type - Copper/No Connector Required, Conductor Code 54P - 1.648-1.746 inch Diameter, Heatsink Size 4 - 2.500 inch Outside Diameter, Heatsink Bore Diameter S - 1.750 inch, Type Shield L - Lead and Neutral Wire, Metallic Screen Continuity Kit Not Required, Armour Kit Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Conductor. Conductor Size AWG Stranded 1250. Aluminum Conductor. Conductor Size AWG Stranded 1000.

35PCJ1Q1440-1410

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Conductor. Conductor Size AWG Stranded 1250. Aluminum Conductor. Conductor Size AWG Stranded 1000.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4, Connector type Copper/no connector required, Connector Code 53P - Conductor Diameter Range - 1.606-1.647 inch (40.79-41.83mm), Heatsink Size 5 - Outside Diameter 2.750 inch ( 69.85mm), Heatsink Bore - R - 1.687 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink standard package

69TCJS44B53P5RDNNB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4, Connector type Copper/no connector required, Connector Code 53P - Conductor Diameter Range - 1.606-1.647 inch (40.79-41.83mm), Heatsink Size 5 - Outside Diameter 2.750 inch ( 69.85mm), Heatsink Bore - R - 1.687 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink standard package
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size R. Copper Connector. 42P. N L F N B

69TCJS1R242PNLFNB

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size R. Copper Connector. 42P. N L F N B
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.725 inch to 1.935 inch. Copper Conductor. Conductor Size AWG Stranded 500.

25PCJ2P2330

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.725 inch to 1.935 inch. Copper Conductor. Conductor Size AWG Stranded 500.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper/no connector required, Connector Code 40P - Conductor Diameter Range - 1.036-1.100 inch (26.31-27.94mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

69TCJS1QB40PNDNNB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper/no connector required, Connector Code 40P - Conductor Diameter Range - 1.036-1.100 inch (26.31-27.94mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 350.

25PCJ2M2290

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 350.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

35PCJ1L2270SG3

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

Frequently Asked Questions

What safety precaution should be taken during installation?

During installation, refer to local code for required Personal Protective Equipment (PPE).

What is the minimum corona extinction voltage for 138 kV joints?

The minimum corona extinction voltage for 138 kV class joints is 120 kV, with 3 pC sensitivity.

What is the minimum corona extinction voltage for 69 kV joints?

The minimum corona extinction voltage for 69 kV class joints is 60 kV, with 3 pC sensitivity.

What is the BIL rating for 138 kV class joints?

The Basic Impulse Level (BIL) rating for 138 kV class joints is 650 kV (1.2 x 50μs; 10 positive, 10 negative impulses).

What is the BIL rating for 69 kV class joints?

The Basic Impulse Level (BIL) rating for 69 kV class joints is 350 kV (1.2 x 50μs; 10 positive, 10 negative impulses).

What is the maximum continuous conductor temperature for TCJ joints?

The maximum continuous conductor temperature for TCJ transmission cable joints is 90 °C.

What is the maximum system voltage for 138 kV class joints?

The maximum system voltage for 138 kV class TCJ joints is 145 kV.

What is the maximum system voltage for 69 kV class joints?

The maximum system voltage for 69 kV class TCJ joints is 72.5 kV.

What voltage classes do TCJ transmission cable joints support?

TCJ transmission cable joints are designed for 46 kV through 138 kV class systems.

What cable insulation diameters are compatible with TCJ joints?

For Style 1 (through 69 kV), insulation diameters range from 1.43 inches to 2.58 inches. For Style 4 (through 138 kV), the range is 2.25 inches to 3.62 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.