Authorized ABB Distributor (Installation Products)
ABB - Installation Products 69TCJN1R136PVAVNB - 69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum, Connector Code 36P - Conductor Diameter Range - .901-.935 inch (22.88-23.75mm), Heatsink Size/Bore - V - 2.046 inch Diameter. Type Shield - A - Copper Tape, Metallic Screen Continuity Kit - V - #2 Flat Braid 6 foot quantity 1, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink

ABB Installation Products 69TCJN1R136PVAVNB 69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1…

UPC: 783786434152


Documents & Media
Specification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 69TCJN1R136PVAVNB is a 69kV transmission cable joint engineered for demanding high-voltage power transmission infrastructure. This specific model is configured with a Non-Shieldbreak Housing Type, utilizing Housing Style 1. The Housing Size is designated as R, and it features a Bore Diameter at the Jacket/Insulation Transition of 1.930 inches. For conductor connection, this joint employs an Aluminum Connector, identified by Connector Code 36P. This connector is designed to accommodate a Conductor Diameter Range of 0.901 to 0.935 inches, which translates to 22.88 to 23.75 millimeters. The integrated heatsink is sized and bored to Size V, with a Diameter of 2.046 inches. The cable shield is of Type A, specifically a Copper Tape shield. To ensure Metallic Screen Continuity, a Metallic Screen Continuity Kit is included, which is Size V and consists of a #2 Flat Braid with a length of 6 feet, quantity 1. An Armor Kit is not required for this configuration, indicated by N. For restoring the outer jacket after installation, an Outer Jacket Restoration Kit is provided, which is of the HeatShrink type, designated as Size B. This comprehensive design ensures robust performance and reliable insulation for 69kV transmission cable systems.
  • 69kV rated transmission cable joint for high-voltage applications
  • Non-shieldbreak housing (Size R) with 1.930" bore diameter at jacket/insulation transition
  • Aluminum connector (Code 36P) for conductor diameters 0.901–0.935" (22.88–23.75mm)
  • Copper tape shield (Type A) with #2 flat braid continuity kit (6-foot)
  • Heatsink bore (Size V) 2.046" diameter; HeatShrink outer jacket restoration kit (Size B)

Specifications

Application
For use on Solid Dielectric Cables - providing permanent, fully-shielded, fully submersible cable joints for direct burial or vault applications
Color
Black
Conductor Range
.901 to .935 in
Connection
Compression
Insulation
Yes
Material
Aluminum
Material
EPDM Rubber
Number Of Conductors
2
Size
Housing Size R, Bore Diameter at Jacket/Insulation Transition 1.930, Conductor Diameter Range 0.901-0.935 inch (22.88-23.75mm), Heatsink Size/Bore 2.046 inch Diameter
Special Features
Each Cable Joint is produced exactly to design, producing a quality not possible with field molding equipment or tape. Electrically tested in the factory to ensure consistent quality. Molding is done in the factory, reducing on-site time - no penciling of cable installation required. Easy to learn installation procedure. Field molds, wrapping machines or pre-stretch not required, and a low-cost assembly tool is available. Extended shelf life enables instant availability of spares. Designed with optimized pre-molded stress control and heat transfer capabilities
Standard
ANSI C119.4, Shield Test IEEE 592
Temperature Rating, Maximum
194 F
Temperature Rating, Maximum
90 C
Temperature Rating, Minimum
194 F
Temperature Rating, Minimum
90 C
Type
Transmission Cable Joint - Non-Shieldbreak
Voltage Rating
69 kV
Package Dimensions (L x W x H)
48.62 IN x 11.37 IN x 10.25 IN
Package Dimensions (L x W x H)
123.4948 cm x 28.8798 cm x 26.035 cm
Package Weight (Imperial)
64.2000 L
Package Weight (Metric)
29.1210 kg
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Aluminum, Connector Code 36P - Conductor Diameter Range - .901-.935 inch (22.88-23.75mm), Heatsink Size/Bore - N - 1.500 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink

69TCJN1Q136PNDNNB

69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Aluminum, Connector Code 36P - Conductor Diameter Range - .901-.935 inch (22.88-23.75mm), Heatsink Size/Bore - N - 1.500 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper/No Connector Required, Connector Code 41P - Conductor Diameter Range - 1.101-1.145 inch (27.96-29.08mm), Heatsink Size/Bore - V - 2.046 inch Diameter. Type Shield - E - Lead, Metallic Screen Continuity Kit - H - 4/0 Bonding Cable 4 foot quantity 2 without Split Bolts, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatSink

69TCJN1QA41PVEHNB

69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper/No Connector Required, Connector Code 41P - Conductor Diameter Range - 1.101-1.145 inch (27.96-29.08mm), Heatsink Size/Bore - V - 2.046 inch Diameter. Type Shield - E - Lead, Metallic Screen Continuity Kit - H - 4/0 Bonding Cable 4 foot quantity 2 without Split Bolts, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatSink
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Only, Housing Size N Bore Diameter at Jacket/Insulation Transition 1.390.

69TCJN1N

69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Only, Housing Size N Bore Diameter at Jacket/Insulation Transition 1.390.
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Only, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930.

69TCJN1R

69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Only, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size P Bore Diameter at Jacket/Insulation Transition 1.570. Connector Type - Copper, Connector Code 40P - Conductor Diameter Range - 1.036-1.100 inch (26.31-27.94mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - L - Lead and Neutral Wires, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

69TCJS1P240PNLNNB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size P Bore Diameter at Jacket/Insulation Transition 1.570. Connector Type - Copper, Connector Code 40P - Conductor Diameter Range - 1.036-1.100 inch (26.31-27.94mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - L - Lead and Neutral Wires, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size N Bore Diameter at Jacket/Insulation Transition 1.390. Connector Type - Copper, Connector Code 30P - Conductor Diameter Range - .636-.686 inch (16.15-17.42mm), Heatsink Size/Bore - E - .921 inch Diameter. Type Shield - B - Copper 1/3 Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - A - Jacket Tape 5 Rolls

69TCJN1N230PEBNNA

69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size N Bore Diameter at Jacket/Insulation Transition 1.390. Connector Type - Copper, Connector Code 30P - Conductor Diameter Range - .636-.686 inch (16.15-17.42mm), Heatsink Size/Bore - E - .921 inch Diameter. Type Shield - B - Copper 1/3 Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - A - Jacket Tape 5 Rolls
35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.725 inch to 1.935 inch. Copper Conductor. Conductor Size AWG Stranded 750.

35PCJ2P2380

35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.725 inch to 1.935 inch. Copper Conductor. Conductor Size AWG Stranded 750.
35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 500. With Sheild Adapter.

35PCJ2N2330-TL

35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 500. With Sheild Adapter.

Frequently Asked Questions

What is the operating voltage for this cable joint?

This cable joint is rated for 69kV transmission applications.

What conductor diameter range does this joint support?

The joint supports conductor diameters from 0.901 to 0.935 inches (22.88 to 23.75mm).

Is a metallic screen continuity kit included?

Yes, the joint includes a #2 flat braid continuity kit (6-foot quantity) for metallic screen continuity.

What type of shield does this joint use?

The joint uses a copper tape shield (Type A) for metallic screen continuity.

Is an armor kit required for this joint?

No, an armor kit is not required for this joint (specified as 'N - not required').

What is the bore diameter at the jacket/insulation transition?

The bore diameter at the jacket/insulation transition is 1.930 inches.

What is the heatsink bore diameter?

The heatsink bore diameter is 2.046 inches (Size V).

What is the outer jacket restoration method?

The outer jacket restoration uses a HeatShrink kit (Size B).

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.