ABB Installation Products 675BEA3 15kv Stick Op Bushing Adapter, 900 Amp, Copper, Includes Silicone Lubricant, Insulated…
UPC: 075114317894
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV voltage class with 8.3kV max phase-to-ground, 14.4kV max phase-to-phase
- 200 Amp continuous and loadbreak current rating with 10kA symmetrical momentary rating
- EPDM molded rubber construction with peroxide-cured insulation and jacket
- All-copper current path with hex-broach torque installation feature
- Includes silicone lubricant (82-08) and installation instructions (IS-0174)
Specifications
Application | 15kV, 900/200 Amps |
Connection | Push-In |
Material | EPDM-Rubber |
Size | 8.89 inc h long x 3.10 inch Diameter |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Bushing Adapter |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

J6-622226-25
6 Point Junction, with one 600 Amp Bushing Interfaces, four 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 25kV, No Tilt Mounting.
655RETP-M0330-S
15kv 600 Amp Test and Ground Replacement Kit- Repair Elbow without Test Point, With Sealing kit, includes Insulated Cap, Reducing Tap Plug, 600 series Elbow Housing, I-adapter, Straight Receptacle, resulting in a net gain of 20 inches in length vs a standard elbow kit. Compression lugs and Cable adapters are ordered separately. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil Compressed Stranded 500, Solid 600.
J5-2BB66-25-SV-N
25/28kV, 600 Amps, Multi-Point Junction. DeadBreak. 5 Points. 1 x 200 Amps Bushing Well Interface, 2 x Blank Positions, 2 x 600 Amps Bushing Interface. Interface Spacing - 6-1/2 inch centers. No Parking Stand.
750ETPSP
35kV 600 Series Deadbreak, Loadbreak Elbow Tap Plug, Factory Assembled Stud, which is not field removable.
CV1000
600 Amp Shearbolt Connector Vise - 15-40MM, Used to hold the Connector Securely in Place during the Shearing Process. Hand Tool. Length 220 mm, Weight 380 g. 2-Color Multilayered Insulation.
655RETP-M0380-S
600 Amp, 15kV, Deadbreak, Test and Ground Replacement Connector Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. 200ECS Cold-Shrinkable Jacket Seal Included.Frequently Asked Questions
What is the 675BEA3 product?
The 675BEA3 is a 15kV 900/200A Stick Op Loadbreak Bushing Adapter. It is constructed of EPDM molded rubber.
What is the continuous and loadbreak current rating?
The 675BEA3 has a 200 Amp continuous and loadbreak current rating.
What material is the 675BEA3 constructed from?
The 675BEA3 is constructed of EPDM molded rubber with peroxide-cured insulation and jacket, and an all copper current path.
What is the momentary and fault close rating?
The momentary and fault close rating is 10kA Sym for 10 Cycles.
What is the corona extinction voltage?
The corona extinction voltage is 11kV AC at 3pC sensitivity.
What is the DC fifteen-minute withstand voltage?
The DC fifteen-minute withstand voltage is 53kV.
What is the AC one-minute withstand voltage?
The AC one-minute withstand voltage is 34kV.
What is the impulse withstand (BIL) rating?
The impulse withstand (BIL) rating is 95kV (1.2 x 50 microsecond wave).
What is the maximum phase-to-ground operating voltage?
The maximum phase-to-ground operating voltage for the 675BEA3 is 8.3kV.
What is the voltage class rating for the 675BEA3?
The 675BEA3 is rated for the 15kV Voltage Class.
How to Install the LINK-C Deadbreak Cam Link Operable Connector System
This guide provides step-by-step instructions for the safe installation and initial setup of the LINK-C 600 amp deadbreak cam link operable connector system, including mounting, wiring, and grounding procedures.
Estimated time: 1h 30m
Tools needed:
Torque wrench, Socket wrench (1 inch hex), Hot stick, Welding equipment (if using welded studs), Wire strippers, Multimeter, 600ATM Operating Tool
Supplies needed:
ELASTIMOLD supplied lubricant, 3/8-16 x 2 inch long studs (3), 3/8-16 hex nuts (minimum 6), 3/8-16 lockwashers (minimum 3), #14 AWG or #12 AWG solid copper wire, Appropriate grounding connector, HV insulated caps (if replacing shipping covers)
- De-energize Apparatus and Prepare for Installation
DANGER: Ensure all apparatus is de-energized before beginning installation or removal of any parts. Verify the system is de-energized using approved test apparatus. If the product was supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit. Read all instructions and have required tools and supplies at hand.
- Install the 600 Amp Elbow onto the Cable
Install the 600 amp elbow onto the cable according to the specific installation instructions supplied with the elbow. Ensure it is positioned to align correctly with the stand-off plug.
- Install the Mounted Stand-Off Plug (If Applicable)
If using a mounted stand-off plug, weld three 3/8-16 x 2 inch long studs to the faceplate according to customer standard practice and specified dimensions. Install three hex nuts onto the studs to support the stand-off plug, ensuring it aligns with the bushing. Install the stand-off plug over the studs, resting on the nuts or optional spacers. Secure the stand-off plug by installing a lockwasher and hex nut on each of the three studs, then tighten to 12 foot-lbs torque. Verify that the top surfaces of the bushing and stand-off plug are in-line; readjust nuts if necessary.
- Install Bushing Extender and Elbow
Clean and thoroughly lubricate the apparatus bushing and both interfaces of the 600 amp bushing extender with ELASTIMOLD supplied lubricant. Install the bushing extender onto the apparatus bushing. Insert the 600ATM into the retainer contact, engage the internal hex broach, and thread the retainer contact into the apparatus bushing using a suitable tool on the 1 inch hex portion of the 600ATM. Torque to 50-60 ft-lbs. Next, clean and lubricate the epoxy standoff plug and both interfaces of the 600 amp elbow with ELASTIMOLD supplied lubricant. Install the elbow onto the epoxy standoff plug. Insert the 600ATM into the retainer contact, engage the internal hex broach, and thread the retainer contact into the epoxy standoff plug through the compression lug hole. Torque to 50-60 ft-lbs.
- Install the Alignment Bracket
Remove the bushing extender clamp and elbow clamp from the alignment bracket. Position the alignment bracket on the bushing extender 2.5 inches (63.5mm) from the grounding eye. Assemble the bushing extender clamp to the alignment bracket with the supplied hardware, torquing by alternating sides until the clamp tabs are flush and tight on both sides.
- Secure the Elbow in the Alignment Bracket
Position the elbow within the alignment bracket, ensuring the elbow cuff is lined up evenly with the bushing extender cuff. Assemble the elbow clamp to the alignment bracket using the supplied hardware. Torque by alternating sides until the clamp tabs are flush with each other and tight on both sides. Ensure the elbow clamp notch faces the cable entrance of the elbow.
- Insert and Engage the Link
Clean and thoroughly lubricate both 600 ampere interfaces of the Link with ELASTIMOLD supplied lubricant. Align the Link so it is perpendicular to the switch faceplate when inserted into the bushing extender and elbow. Insert the Link, ensuring both lever arms are on the inside of the alignment bracket legs. Engage the pivot pin into the slots in the alignment bracket legs. While pushing inward, use a hot stick to move the lever arms downward, engaging the roller pin and moving the Link inward. Continue moving the lever arms until they are perpendicular to the alignment bracket leg.
- Ground the Elbow and Install Mating Products
Ground the elbow by feeding a #14 AWG or #12 AWG solid copper wire through the grounding eye, twisting it tight, and connecting it to ground. Clean and lubricate the 200 amp interface on the Link. Ground and then install the desired mating product onto the 200 amp interface according to its specific installation instructions. Ground the cable: if using concentric neutral cable, twist the neutral wires together and connect to ground with an appropriate connector; if using 20MA or 21MA grounding devices, connect the ground lead to ground with a suitable connector. For three-phase installations, tie all grounds from all three phases to a common ground point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.