ABB Installation Products 750ETPSP 35kV 600 Series Deadbreak, Loadbreak Elbow Tap Plug, Factory Assembled Stud, which is…
UPC: 783786022106
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 35kV voltage class, single-phase only
- 200 Amp continuous and loadbreak rated, 600 Amp continuous for mating connector
- Meets ANSI/IEEE Standard 386 with 150kV BIL impulse withstand
- Factory-assembled stud eliminates field assembly steps
- Compatible with 375DRG, 376DRG, 375ESA-XX, 375LR, and 370GLR connectors
Specifications
Application | 35 kV, 600 Amps |
Connection Type | Factory-Assembled Stud (Not Field Removable) |
Current Rating | 600 A |
Material | Composite (Elastomer/Insulation) |
Mounting Type | Elbow Tap Plug |
Series | 600 Series |
Size | 600 Series |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Elbow Tap Plug |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K675TBC
15/25kV, 900 Amp, Deadbreak Bushing for In-Air Applications (Pad-Mounted or Vault-Type or Submersible Transformers or Switchgear). One Factory installed 5/8-11 UNC-2A Stud included, other Stud must be Purchased Separately. Overall Length 13.75 inch, Diameter 4.50 inch. Molded Epoxy with Stainless Steel Flange. Boot and Collar.
CV1000
600 Amp Shearbolt Connector Vise - 15-40MM, Used to hold the Connector Securely in Place during the Shearing Process. Hand Tool. Length 220 mm, Weight 380 g. 2-Color Multilayered Insulation.
655RETP-M0380-S
600 Amp, 15kV, Deadbreak, Test and Ground Replacement Connector Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. 200ECS Cold-Shrinkable Jacket Seal Included.
200-30-1
Stainlesss Steel Coil Spring In The 200ECSG2-2 Kit. Total Length 18 inch. Inside Diameter .45 inch, Width .5 inch, Thickness .006 inch.Frequently Asked Questions
What is the primary application of the 750ETP?
The 750ETP elbow tap plug permits a 200 Amp tap off of a mating 600 Amp connector.
What is the maximum phase-to-phase voltage?
The maximum phase-to-phase voltage for the 750ETP is 36.6kV.
How can I order the 750ETP with a factory-assembled stud?
To order the 750ETP with a factory-assembled stud, add "SP" to the part number.
What items are included in the 750ETP kit?
Each kit includes one elbow tap plug, a protective shipping cap (2701-41), two lubricants (82-08), and installation instructions (IS-1155).
Is the loadbreak interface designed for energized operation?
Yes, the loadbreak interface of the 750ETP is designed for energized operation.
What is the continuous and loadbreak current rating?
The 750ETP has a 200 Amp continuous and loadbreak current rating.
What is the maximum phase-to-ground operating voltage?
The maximum phase-to-ground operating voltage for the 750ETP is 21.1kV.
What is the voltage class for the 750ETP?
The 750ETP is designed for a 35kV voltage class and is rated for single phase application only.
What products are compatible with the 750ETP?
The 750ETP mates with Elastimold products including 375DRG, 376DRG, 375ESA-XX, 375LR, and 370GLR.
What tool is required for 750ETP installation?
The 750ETP elbow tap plug is installed using a 600ATM assembly tool.
How to Install the LINK-C Deadbreak Cam Link Operable Connector System
This guide provides step-by-step instructions for the installation and initial setup of the LINK-C 600 amp deadbreak cam link operable connector system, including mounting, wiring, and grounding procedures. Ensure all safety warnings are observed.
Estimated time: 1h
Tools needed:
Torque Wrench, Wrench/Socket (for 1 inch hex), Hot Stick, 600ATM Operating Tool, Wire Strippers, Welding Equipment (if mounting studs)
Supplies needed:
600 Amp Elbow (specific to cable), Standoff Plug (specific to apparatus), ELASTIMOLD Supplied Lubricant, 3/8-16 x 2 inch Studs (3, if applicable), 3/8-16 Hex Nuts (6, if applicable), 3/8-16 Lockwashers (3, if applicable), Alignment Bracket, 600 Amp Bushing Extender, Mounting Hardware (for clamps, typically supplied), #14 AWG or #12 AWG Solid Copper Grounding Wire, Appropriate Grounding Connectors, Desired 200 Amp Mating Product, HV Insulated Caps (if not immediately connecting a mating product)
- Prepare for Installation
DANGER: De-energize all apparatus before beginning installation or removal of parts. Inspect all components for damage, proper rating, and compatibility with mating parts. Ensure all required tools and supplies are at hand and maintain cleanliness throughout the procedure. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices.
- Install 600 Amp Elbow on Cable
Install the 600 amp elbow onto the cable according to the installation instructions supplied with the elbow. Ensure it will align correctly with the standoff plug.
- Determine Mounting Configuration
Determine whether you are installing the 'Alignment Bracket with Bolted Stand-Off Plug' or the 'Alignment Bracket' only. If installing with a bolted stand-off plug, proceed to Step 4. Otherwise, skip to Step 5.
- Mount Bolted Stand-Off Plug (If Applicable)
Weld three 3/8-16 x 2 inch studs to the faceplate per customer standard practice and specified dimensions. Install three hex nuts onto the studs to support the standoff plug, ensuring it aligns with the bushing. Place the standoff plug over the studs, resting on the nuts or optional spacers. Secure with a lockwasher and hex nut on each stud, torquing to 12 ft-lbs. Verify the top surfaces of the apparatus bushing and standoff plug are in-line; readjust nuts if needed.
- Install Bushing Extender and Elbow
Clean and thoroughly lubricate the apparatus bushing and both interfaces of the 600 amp bushing extender with ELASTIMOLD supplied lubricant. Install the bushing extender onto the apparatus bushing. Insert the 600ATM into the retainer contact and engage the internal hex broach. Insert the retainer contact into the bushing extender and thread into the apparatus bushing using a suitable tool on the 1 inch hex portion of the 600ATM, torque to 50-60 ft-lbs. Repeat cleaning, lubricating, and installation for the elbow onto the epoxy standoff plug, torquing to 50-60 ft-lbs.
- Attach Alignment Bracket to Bushing Extender
Remove the bushing extender clamp and elbow clamp from the alignment bracket. Position the alignment bracket on the bushing extender 2.5 inches (63.5mm) from the grounding eye. Assemble the bushing extender clamp to the alignment bracket with supplied hardware. Torque by alternating sides until clamp tabs are flush with each other and tight on both sides.
- Secure Elbow in Alignment Bracket
Position the elbow in the alignment bracket such that the elbow cuff is lined up evenly with the bushing extender cuff. Assemble the elbow clamp to the alignment bracket with supplied hardware. Torque by alternating sides until clamp tabs are flush with each other and tight on both sides. Ensure the elbow clamp notch faces the cable entrance of the elbow.
- Insert and Engage the Link
Clean and thoroughly lubricate both 600 ampere interfaces of the Link with ELASTIMOLD supplied lubricant. Align the Link so it is perpendicular to the switch faceplate when inserted into the bushing extender and elbow. Insert the Link into the bushing extender and elbow, ensuring both lever arms are inside the alignment bracket legs. Engage the pivot pin into the slots in the alignment bracket legs. While pushing inward, use a hot stick to move the lever arms downward, engaging the roller pin and moving the Link inward. Continue until lever arms are perpendicular to the alignment bracket leg.
- Ground System and Connect Mating Product
Ground the elbow: Feed #14 AWG or #12 AWG solid copper wire through the grounding eye on the elbow, twist tight, and connect to ground. Clean and lubricate the 200 amp interface on the Link. Ground, then install the desired 200 amp mating product onto the 200 amp interface per its specific installation instructions. Ground the cable: If using concentric neutral cable, twist neutral wires together and connect to ground. If using 20MA or 21MA grounding devices, connect the ground lead to ground. For three-phase installations, tie all grounds from all three phases to a common ground point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.