Authorized ABB Distributor (Installation Products)
ABB - Installation Products 655LRTP-N0410-DRG - 600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, With Insulated Cap. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

ABB Installation Products 655LRTP-N0410-DRG 600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, With Insulated Cap. Cable Insulation…

UPC: 783786646593


Documents & Media
Installation InstructionsManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 600 Amp, 15kV Deadbreak Stick-Op Connector Kit, SKU 655LRTP-N0410-DRG, is designed for reliable electrical connections in medium-voltage applications. It features an insulated cap for enhanced safety and ease of operation, reducing the risk of accidental contact during installation or maintenance. The kit is engineered to accommodate cable insulation diameters ranging from 1.515 inches to 1.780 inches, ensuring compatibility with a defined range of cable sizes. The connector utilizes an aluminum compression lug for robust and secure conductor termination, providing long-term reliability and corrosion resistance. It is specified for compressed stranded conductors up to 1000 kcmil, offering a substantial capacity for high-current circuits while maintaining low resistance and optimal current-carrying performance. This connector is suitable for applications requiring deadbreak termination technology, where the connection is de-energized before separation, ensuring safety during disconnection. The ABB Installation Products brand signifies a commitment to quality and performance in electrical infrastructure, backed by rigorous testing and industry standards. UNSPSC Code: 39121421.
  • 600 Amp current rating
  • 15kV voltage rating
  • Deadbreak Stick-Op connector design
  • Accommodates 1.515" to 1.780" cable insulation diameter
  • Includes aluminum compression lug for 1000 kcmil conductors

Specifications

Amperage Rating
600 to 200 A
Application
Connect 600 Amp interface to 200 Amp Loadbreak Tap
Color
Black
Conductor Range
1000 kcmil
Connection Type
Deadbreak Stick-Op
Current Rating
600 A
Enclosure
Yes, EPDM Rubber
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Housing - EPDM-Rubber
Material
Aluminum
Size
1.515 inch to 1.780 inch
Special Features
Reducing Tap Plug 600 to 200 Amps. Provides an External Visible Break by Hotstick Removal of the Elbow
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Stick Op Reducing Tap Plug Connector
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. 2 X (Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000. )

K656I-P0410-P0410

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. 2 X (Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000. )
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, With Insulated Cap. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

655LRTPL0330DRG

600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, With Insulated Cap. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Stick-OP Elbow Connector Kit, Insulated Cap. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300.

656LRTP-J2280-DRG

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Stick-OP Elbow Connector Kit, Insulated Cap. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Stick-OP Elbow Connector Kit. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300.

656LRTP-J2280

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Stick-OP Elbow Connector Kit. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300.
600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, With Insulated Cap. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

655LRTP-M2380-DRG

600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, With Insulated Cap. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Stick-OP Elbow Connector Kit, Insulated Cap. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 300 /Compacted Solid 350 /mmSquared Compact 150.

656LRTP-J0290-DRG

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Stick-OP Elbow Connector Kit, Insulated Cap. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 300 /Compacted Solid 350 /mmSquared Compact 150.
600 Amp, 25kV, Deadbreak, Stick-Op Connector Kit with Test Point, Fixed Bolt, Cable Insulation Diameter 1.370 inch to 1.630 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

K656LRTPFB-M5380

600 Amp, 25kV, Deadbreak, Stick-Op Connector Kit with Test Point, Fixed Bolt, Cable Insulation Diameter 1.370 inch to 1.630 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

How to Install the ELASTIMOLD 160DRG/167DRG Insulated Cap with Ground Lead

This guide provides instructions for safely installing the ELASTIMOLD 160DRG and 167DRG insulated caps, designed for insulating, shielding, and watersealing 15kV class loadbreak bushing interfaces. Ensure all safety precautions are followed.

Estimated time: 20m

Tools needed:

Hotstick, Wire strippers, Multimeter

Supplies needed:

ELASTIMOLD 160DRG/167DRG Insulated Cap with Ground Lead, ELASTIMOLD Approved Lubricant, Grounding wire connection hardware

  1. De-energize and Inspect System

    DANGER: Ensure all apparatus is completely de-energized before beginning installation. Verify the system is de-energized using appropriate testing equipment. Inspect all parts for damage, correct rating, and compatibility with mating components. This product must be installed by competent personnel trained in high voltage electrical equipment safety practices.

  2. Connect Electrostatic Grounding Wire

    Connect the free end of the electrostatic grounding wire to the system ground. Leave sufficient slack in the wire to allow for hot-stick operation of the insulated cap. CAUTION: Train the electrostatic grounding wire to prevent it from contacting the bushing interface during operation. WARNING: If the ground lead disconnects during operation, do not attempt to reattach it without first pulling the insulated cap off the bushing with a hotstick.

  3. Prepare Insulated Cap for Installation

    Remove the protective cover from the insulated cap. Thoroughly lubricate the cap’s internal mating surface using only the supplied ELASTIMOLD approved lubricant. DO NOT substitute other lubricants, as they may cause harm to the product. Ensure the internal mating surface remains free from dirt and grime. Replace the protective cover when the cap is not in use.

  4. Install Insulated Cap onto Bushing

    Firmly attach a full insulated hotstick to the pulling eye of the insulated cap. Carefully insert the male contact of the insulated cap into the loadbreak bushing. Push the cap home with a fast, firm, and straight motion until it is fully mated and the locking ring is securely seated. Detach the hotstick from the insulated cap.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.