Authorized ABB Distributor (Installation Products)
ABB - Installation Products 655ETP-K0330-DRG - 15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

ABB Installation Products 655ETP-K0330-DRG 15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test…

UPC: 783786093571


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 655ETP-K0330-DRG is a 15kV 600 Series Deadbreak Elbow TAP PLUG Connector Kit designed for reliable electrical connections in medium voltage applications. This comprehensive kit includes essential components for safe and effective installation and maintenance. Key components provided in the 655ETP-K0330-DRG kit are: * Insulated Cap: For secure sealing and protection. * Test and Ground Reducing Tap Plug: Facilitates testing and grounding procedures. * 600 Series Elbow Housing: The primary component for deadbreak connection. * Cable Adapter: Ensures compatibility with various cable sizes. * 0370 Style Compression Lug: Made from aluminum, designed for secure conductor termination. This kit is engineered to accommodate cable insulation diameters ranging from 1.090 inches to 1.310 inches. The included aluminum compression lug is suitable for compressed stranded conductors up to 500 kcmil, compacted solid conductors up to 600 kcmil, and mm² compact conductors of 250/300. The 600 Series design ensures a deadbreak connection, providing a high level of safety and reliability for utility and industrial power distribution systems. The SKU for this product is 655ETP-K0330-DRG, manufactured by ABB - Installation Products.
  • 15kV voltage rating for medium voltage applications
  • 600 Series Deadbreak Elbow TAP PLUG Connector Kit
  • Accommodates cable insulation diameters from 1.090" to 1.310"
  • Includes insulated cap, test/ground reducing tap plug, elbow housing, cable adapter, and aluminum compression lug
  • Aluminum compression lug supports conductor sizes up to 500 kcmil stranded / 600 kcmil solid

Specifications

Amperage Rating
600 A
Application
600 Amps, 15kV
Color
Black
Conductor Range
500 STR/COMPR kcmil , 600 SOL/COMPT kcmil
Connection
Compression
Connection Type
Deadbreak Elbow
Insulation
EPDM Rubber
Material
Housing - EPDM-Rubber
Material
Aluminum
Series
600 Series
Size
Cable Insulation Diameter 1.090 inch to 1.310 inch
Size
1.090 inch to 1.310 inch
Special Features
Includes Insulated Cap
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Window-Op Connector
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
3.5000 L
Package Weight (Metric)
1.5880 kg
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

655ETP-L0330

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
600 Amp Dead Break Elbow Connector, Test and Ground Connector Kit, 15 KV, Cable Insulation Diameter 1090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 350 /Solid 400 /mmSquared 185.

655ETP-K0300-DRG

600 Amp Dead Break Elbow Connector, Test and Ground Connector Kit, 15 KV, Cable Insulation Diameter 1090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 350 /Solid 400 /mmSquared 185.
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

655ETP-J0270-DRG

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Window-Op Connector Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

656ETP-M0380

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Window-Op Connector Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

655ETP-L0380-DRG

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Window-Op Connector Kit. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

656ETP-J0270

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Window-Op Connector Kit. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Window-Op Connector Kit. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

656ETP-L0330

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Window-Op Connector Kit. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Window-Op Connector Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.

656ETP-M0360

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Window-Op Connector Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.

Frequently Asked Questions

What is the maximum phase-to-phase voltage rating?

The maximum phase-to-phase voltage rating for this connector is 14.4kV.

What is the maximum phase-to-ground operating voltage?

The maximum phase-to-ground operating voltage for this connector is 8.3kV.

What is the voltage class of this connector kit?

This WINDOW-OP Connector Kit is designed for a 15kV Voltage Class.

What are WINDOW-OP connectors used for?

WINDOW-OP connectors allow direct testing and grounding without cable movement. They are ideal for equipment with viewing windows, providing a visible break without hotstick elbow removal.

What is the continuous current rating?

The continuous current rating for this connector is 600 Amps.

What is the momentary current rating?

The momentary current rating is 25kA Symmetrical for 10 Cycles.

What are WINDOW-OP connectors used for?

WINDOW-OP connectors allow direct testing and grounding without cable movement. They are ideal for equipment with viewing windows, providing a visible break without hotstick elbow removal.

What is the momentary current rating?

The momentary current rating is 25kA Symmetrical for 10 Cycles.

What is the continuous current rating?

The continuous current rating for this connector is 600 Amps.

What is the maximum phase-to-phase voltage rating?

The maximum phase-to-phase voltage rating for this connector is 14.4kV.

How to Install the 160DRG/167DRG Insulated Cap with Ground Lead

This guide provides instructions for the safe installation of the 160DRG and 167DRG Insulated Caps with Ground Lead, designed for insulating, shielding, and watersealing 15kV class loadbreak bushing interfaces.

Estimated time: 15m

Tools needed:

Hotstick

Supplies needed:

160DRG or 167DRG Insulated Cap with Ground Lead, Lubricant (supplied or ELASTIMOLD approved)

  1. Connect Grounding Wire

    DANGER: All apparatus must be de-energized during installation. Connect the free end of the electrostatic grounding wire to the system ground. Ensure enough slack is left for hot-stick operation of the insulated cap. CAUTION: Train the electrostatic grounding wire so it does not contact the bushing interface during operation.

  2. Prepare Insulated Cap

    Remove the protective cover from the insulated cap. Lubricate the cap's internal mating surface using only the supplied lubricant or ELASTIMOLD approved lubricants. DO NOT SUBSTITUTE, as other lubricants may be harmful to this product and its mating products. Keep the internal mating surface free from dirt and grime. Always replace the protective cover when not in use.

  3. Install Insulated Cap

    Firmly attach a hotstick to the insulated cap pulling eye. Insert the male contact of the insulated cap into the loadbreak bushing. Push the cap home with a fast, firm, straight motion, making certain it is fully mated with the locking ring seated. Detach the hotstick from the insulated cap.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.