Authorized ABB Distributor (Installation Products)
ABB - Installation Products 655ETP-F0230-DRG - 15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50. With Insulated Cap.

ABB Installation Products 655ETP-F0230-DRG 15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test…

UPC: 783786198924


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 655ETP-F0230-DRG 15kV 600 Series Deadbreak Elbow TAP PLUG Connector Kit delivers a reliable, field-proven solution for underground distribution systems requiring safe, deadbreak connections with integrated test and ground provisions. This kit is engineered for conductors ranging from AWG or kcmil #1/0 (compressed stranded) or 1/0 (compacted solid) up to 50 mm² (compact), accommodating cable insulation diameters between 0.640 inches and 0.820 inches. The kit includes an insulated cap for safety during non-use or testing, a reducing tap plug for standardized testing and grounding points, a 600 series elbow housing, a cable adapter, and a 0370 style aluminum compression lug for a robust electrical connection. Designed for 15 kV applications, this deadbreak connector kit ensures system integrity and personnel safety by enabling energized operation without service interruption. The 600 series elbow housing is a standard in many underground distribution systems, providing compatibility with existing infrastructure. The aluminum compression lug ensures a secure, high-conductivity connection, while the insulated cap adds an additional layer of protection when the connector is not in use or during maintenance procedures. This product is suitable for applications requiring deadbreak connection capabilities with integrated test and ground provisions, facilitating safe and efficient electrical system maintenance and operation. The kit is part of ABB's Installation Products line, ensuring compatibility with industry-standard components and tools. For installation, use the appropriate ABB assembly tools to ensure proper torque and alignment. Key specifications include: - Voltage class: 15 kV - Conductor size range: #1/0 AWG/kcmil to 50 mm² (compact) - Cable insulation diameter: 0.640 inch to 0.820 inch - Continuous current rating: 200 Amp - Compression lug: 0370 style, aluminum - Includes: Insulated cap, reducing tap plug, elbow housing, cable adapter, and compression lug
  • 15 kV deadbreak elbow tap plug connector kit for underground distribution systems
  • Accommodates conductors from #1/0 AWG/kcmil to 50 mm² (compact) with 0.640-0.820 inch cable insulation
  • Includes insulated cap, reducing tap plug, 600 series elbow housing, cable adapter, and 0370 style aluminum compression lug
  • 200 Amp continuous current rating with integrated test and ground provisions for safe energized operation
  • Aluminum Compression Lug for reliable conductor connection

Specifications

Amperage Rating
600 A
Application
600 Amps, 15kV
Color
Black
Conductor Range
#1 STR/COMPR AWG , 1/0 SOL/COMPT AWG
Connection
Compression
Current Rating
600 A
Insulation
EPDM Rubber
Material
Housing - EPDM-Rubber
Material
Aluminum
Series
600 Series
Size
Cable Insulation Diameter 0.640 inch to 0.820 inch
Size
0.640" - 0.820"
Special Features
Includes Insulated Cap
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Window-Op Connector
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
3.5000 L
Package Weight (Metric)
1.5880 kg
15kV, 200 Amp, LoadBreak, Repair Elbow Connector with Test Point/Extended Elbow, Cable Insulation .665-.895 inches, Bi-Metal Compression Lug, Conductor Size #1 Stranded/Compressed or 1/0 Compact/Solid. No Seal.

168ELR-6689-5230

15kV, 200 Amp, LoadBreak, Repair Elbow Connector with Test Point/Extended Elbow, Cable Insulation .665-.895 inches, Bi-Metal Compression Lug, Conductor Size #1 Stranded/Compressed or 1/0 Compact/Solid. No Seal.
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

655ETP-K0330-DRG

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
600 Amp Dead Break Elbow Connector, Test and Ground Connector Kit, 15 KV, Cable Insulation Diameter 1090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 350 /Solid 400 /mmSquared 185.

655ETP-K0300-DRG

600 Amp Dead Break Elbow Connector, Test and Ground Connector Kit, 15 KV, Cable Insulation Diameter 1090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 350 /Solid 400 /mmSquared 185.
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

655ETP-J0270-DRG

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Window-Op Connector Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

656ETP-M0380

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Window-Op Connector Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

655ETP-L0380-DRG

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Window-Op Connector Kit. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

656ETP-J0270

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Window-Op Connector Kit. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Window-Op Connector Kit. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

656ETP-L0330

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Window-Op Connector Kit. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

Frequently Asked Questions

What components are included in the WINDOW-OP Connector Kit?

The kit includes an Elbow Housing, LB Elbow Tap Plug, Insulated Cap, Cable Size Adapter, Compression Lug, Stud, Silicone Lubricant, Crimp Chart, and Instruction Sheets.

What is the continuous current rating of the connector?

The WINDOW-OP connector has a continuous current rating of 600 Amps.

What is the maximum operating voltage for this connector?

The maximum phase-to-ground operating voltage for the 15kV class connector is 8.3kV, and the maximum phase-to-phase is 14.4kV.

What are the applications of WINDOW-OP connectors?

WINDOW-OP connectors allow direct testing and grounding without required cable movement. They are ideal for equipment with viewing windows, providing an internal visible break without hotstick elbow removal.

What is the maximum operating voltage for this connector?

The maximum phase-to-ground operating voltage for the 15kV class connector is 8.3kV, and the maximum phase-to-phase is 14.4kV.

What components are included in the WINDOW-OP Connector Kit?

The kit includes an Elbow Housing, LB Elbow Tap Plug, Insulated Cap, Cable Size Adapter, Compression Lug, Stud, Silicone Lubricant, Crimp Chart, and Instruction Sheets.

What is the continuous current rating of the connector?

The WINDOW-OP connector has a continuous current rating of 600 Amps.

What are the applications of WINDOW-OP connectors?

WINDOW-OP connectors allow direct testing and grounding without required cable movement. They are ideal for equipment with viewing windows, providing an internal visible break without hotstick elbow removal.

What standards does the WINDOW-OP connector meet?

The WINDOW-OP connector meets ANSI/IEEE Standard 386, Latest Revision.

What is the impulse withstand rating (BIL) of the connector?

The connector has a 95kV BIL (Basic Impulse Level) impulse withstand rating, measured with a 1.2 x 50 microsecond wave.

How to Install the 655ETP-F0230-DRG Insulated Cap with Ground Lead

Instructions for installing and removing the 655ETP-F0230-DRG insulated cap with ground lead on a loadbreak bushing interface.

Estimated time: 30m

Tools needed:

Hotstick, Screwdriver (for system ground connection, if applicable)

Supplies needed:

Insulated Cap with Ground Lead, Lubricant (supplied or ELASTIMOLD approved), Mounting screws (if applicable for system ground)

  1. Connect the electrostatic grounding wire

    Connect the free end of the electrostatic grounding wire to the system ground. Ensure there is enough slack for hot-stick operation. CAUTION: Train the grounding wire so it does not contact the bushing interface during operation. WARNING: If the ground lead disconnects during operation, do not attempt to reattach without first pulling the insulated cap off the bushing with the hotstick.

  2. Prepare the insulated cap

    Remove the protective cover from the insulated cap. Lubricate the cap's internal mating surface using only the supplied lubricant or ELASTIMOLD approved lubricants. DO NOT SUBSTITUTE. Keep the internal mating surface free from dirt and grime. Always replace the protective cover when not in use.

  3. Install the insulated cap

    Firmly attach the hotstick to the insulated cap's pulling eye. Insert the male contact of the insulated cap into the loadbreak bushing. Push home with a fast, firm, straight motion, ensuring it is fully mated and the locking ring is seated. Detach the hotstick from the insulated cap.

  4. Remove the insulated cap

    Attach the hotstick to the pulling eye. Before pulling, rotate the insulated cap clockwise while in the mated position to break surface friction. Pull the receptacle off with a fast, firm, straight motion. Remove the electrostatic grounding wire of the insulated cap from the system ground. Replace the protective cover on the insulated cap to keep its internal surface clean.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.