Authorized ABB Distributor (Installation Products)
ABB - Installation Products 600ECS - Cold-Shrinkable Jacket Seal. Size Range 1.28 inch to 2.30 inch jacket diameters. Maximum installed diameter is approximately 2.75 inches. Submersible and UV Resistant 8 inch long x 2.9 inch Diameter

ABB Installation Products 600ECS Cold-Shrinkable Jacket Seal. Size Range 1.28 inch to 2.30 inch jacket diameters. Maximum…

UPC: 783786644353


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 20

Multiplier: 20

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 600ECS Cold-Shrink Jacket Seal (SKU: 600ECS) from ABB Installation Products is a cold-shrinkable restoration system designed for jacketed concentric neutral power cables, including XLP, EPR, and similar solid dielectric insulated cables. This seal restores compromised cable jackets while providing necessary shielding for reliable performance in critical applications. Key specifications include: - **Voltage Classes**: 15kV, 25kV, and 35kV ratings with phase-to-ground and phase-to-phase operating voltages up to 21.1kV and 36.6kV respectively. - **Impulse Withstand**: 95kV BIL (15kV class), 125kV BIL (25kV class), and 150kV BIL (35kV class) for transient protection. - **Continuous & Loadbreak Current**: 200 Amp rating for sustained operation and fault conditions. - **Momentary & Fault Close**: 10kA symmetrical for 10 cycles, ensuring resilience under fault events. - **Corona Extinction**: 3pC sensitivity at 11kV (15kV class), 19kV (25kV class), and 26kV (35kV class) for partial discharge resistance. - **Physical Dimensions**: 8 inches in length with a 2.9-inch diameter, accommodating jacket diameters from 1.28 inches to 2.30 inches (maximum installed diameter: 2.75 inches). The 600ECS is compatible with jacketed concentric neutral cables and integrates seamlessly with Elastimold products such as K655LR, K655SR, and 35PCJ. Its cold-shrink technology eliminates the need for heat or specialized tools, enabling a place-and-pull installation process that saves time and reduces labor costs. The seal is submersible and UV-resistant, making it ideal for outdoor installations, utility infrastructure, and environments where moisture ingress or sunlight exposure is a concern. The 600ECS is part of ABB’s ECS series, known for reliable sealing and protection in power distribution systems.
  • Cold-shrink jacket seal restoration for XLP, EPR, and solid dielectric insulated power cables
  • Compatible with jacketed concentric neutral cables and Elastimold accessories (e.g., K655LR, 35PCJ)
  • 200 Amp continuous/loadbreak current, 10kA momentary fault rating, and 3pC corona extinction sensitivity
  • Submersible, UV-resistant, and tool-free installation with 8" length x 2.9" diameter
  • 8 inch length x 2.9 inch diameter

Specifications

Application
Sealing and Grounding, 600 Amp
Color
Black
Special Features
Cold Shrink Jacket Seal Restoration Kit. Easy to Use, Place and Pull Install. Provides Sealing and Protection on Jacketed Concentric Neutral Cable. No Tools Required to Install. Size Range 1.28 inch to 2.30 inch Jacket Diameters. Maximum Installed Diameter is approximately 2.75 inches. 8 inches in Length. Submersible and UV Resistant
Standard
ANSI/IEEE Standard 386, Latest Revision
Type
Cable Jacket Seal
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
0.4800 L
Package Weight (Metric)
0.2180 kg
Cold-Shrinkable Jacket Seal Size Range .80 inch to 1.50 inch jacket diameters. Maximum installed diameter is approximately 2 inches. 7 inches long. Submersible and UV Resistant

200ECS

Cold-Shrinkable Jacket Seal Size Range .80 inch to 1.50 inch jacket diameters. Maximum installed diameter is approximately 2 inches. 7 inches long. Submersible and UV Resistant
Switch Seals & Accessories, Pushbutton Switch Boot Seal, Round Product Shape, Black, ​Alcoswitch CAP

1825069-1

Switch Seals & Accessories, Pushbutton Switch Boot Seal, Round Product Shape, Black, ​Alcoswitch CAP
Switch Seals & Accessories, Pushbutton Switch Boot Seal, Round Product Shape, Black, Alcoswitch FCR

1825610-1

Switch Seals & Accessories, Pushbutton Switch Boot Seal, Round Product Shape, Black, Alcoswitch FCR
Switch Seals & Accessories, Guard, Round Product Shape

8-1437627-3

Switch Seals & Accessories, Guard, Round Product Shape
Switch Seals & Accessories, Guard, Round Product Shape

8-1437627-4

Switch Seals & Accessories, Guard, Round Product Shape
Switch Seals & Accessories, Guard, Round Product Shape, Black

8-1437627-2

Switch Seals & Accessories, Guard, Round Product Shape, Black
Switch Seals & Accessories, Guard, Round Product Shape

9-1437627-3

Switch Seals & Accessories, Guard, Round Product Shape

Frequently Asked Questions

What is the size range for the 600ECS jacket seal?

The ABB 600ECS jacket seal is designed for cable jacket diameters ranging from 1.28 inches to 2.30 inches.

What is the maximum installed diameter of the 600ECS seal?

The maximum installed diameter for the ABB 600ECS jacket seal is approximately 2.75 inches.

Is the 600ECS jacket seal suitable for outdoor use?

Yes, the ABB 600ECS jacket seal is UV resistant, making it suitable for outdoor applications.

Can the 600ECS jacket seal be used in wet conditions?

Yes, the ABB 600ECS jacket seal is submersible and designed for use in wet environments.

What are the dimensions of the 600ECS jacket seal?

The ABB 600ECS jacket seal measures 8 inches in length and has a diameter of 2.9 inches.

How to Install the 600 ECS Jacketed Cable Sealing Kit

This guide provides step-by-step instructions for installing the 600 ECS Jacketed Cable Sealing Kit on jacketed concentric neutral shielded cable, ensuring a proper seal and connection.

Tools needed:

Standard electrical installation tools

Supplies needed:

600 ECS Cold Shrink Tube, Mastic strips (3 pieces), Jacketed concentric neutral shielded cable, Elbow, joint, or terminator, Vinyl tape

  1. Perform Pre-Installation Checks and Ensure Safety

    Before starting, ensure all apparatus is de-energized. Inspect all parts for damage, rating, and compatibility with mating parts and the cable. Verify the package contents are complete and undamaged. Read the entire installation instructions thoroughly and have all required tools at hand, maintaining cleanliness throughout the procedure. Ensure exposed semi-con between the cable jacket and device end is no more than 2-1/2 inches (64mm). DANGER: All apparatus must be de-energized during installation or removal. Failure to follow instructions will result in damage, serious or fatal injury. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices.

  2. Prepare Cable Jacket and Apply First Mastic Strip

    Remove the cable jacket for a distance of 2-1/2 inches (64mm) more than the cutback length for the cable semicon, as specified in the manufacturer's instructions. Wrap the first mastic strip around the cable jacket 0 to 1/4 inch (0-6mm) from the end, stretching as needed to completely encircle the cable. Bend the ground wires back over the mastic and along the jacket, pressing them into the mastic. IMPORTANT: Ensure ground wires do not touch each other to allow a complete seal around each wire and prevent water ingress.

  3. Apply Second Mastic Strip and Tape

    Wrap the second mastic strip over the ground wires, above the previously applied mastic. Press the mastic to fill any voids. Overwrap the mastic and wires tightly with two half-lapped layers of vinyl tape for a width of approximately 1-1/2 inches (40mm). Prepare the cable end according to the manufacturer's instructions for the specific elbow, joint, or terminator being used.

  4. Slide Cold Shrink Tube and Install Connector

    Slide the cold shrink tube onto the cable with the loose end facing away from where the connector will be installed. Install the elbow, joint, or terminator following its manufacturer's instructions.

  5. Apply Third Mastic Strip and Activate Cold Shrink Tube

    For 600amp products, wrap the third mastic strip immediately below the product, overlapping the cable entrance of the cable adapter. For terminators, wrap the third mastic strip immediately below the stress cone. Overwrap the mastic with two half-lapped layers of vinyl tape for both applications. Pull the loose end from the back of the cold shrink tube and unwind the cord in a clockwise direction until the plastic core is flush with the end of the cold shrink tube. Slide the cold shrink tube into its final position and continue to unwind the cord clockwise. The cold shrink tube will collapse at the product end first. IMPORTANT: The tube must overlap the elbow or joint end by at least 1 inch (25mm) for a proper seal.

  6. Connect Concentric Neutral Wires

    Connect the elbow, joint, or terminator to the concentric neutral wires according to the manufacturer's instructions for the specific product.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.