Authorized ABB Distributor (Installation Products)
ABB - Installation Products 35PCJ2K2250-TL - 35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0. With Sheild Adapter.

ABB Installation Products 35PCJ2K2250-TL 35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable…

UPC: 783786416424


Documents & Media
BrochureManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 35kV Power Cable Joint Style 2 (SKU: 35PCJ2K2250-TL) is engineered for the reliable termination of medium voltage power cables. This comprehensive kit incorporates a universal housing, specifically designed to accommodate a broad spectrum of cable insulation diameters, ranging from a minimum of 1.090 inches to a maximum of 1.310 inches. The joint is meticulously constructed for use with copper conductors. It supports a variety of conductor sizes, including stranded 2/0 AWG and solid 3/0 AWG. The kit's design emphasizes a secure and precise connection through the inclusion of separate cable adapters, ensuring compatibility with diverse cable configurations. Furthermore, this joint kit is equipped with a shield adapter, a critical component for maintaining the integrity of the cable's shielding system, thereby ensuring safe and efficient operation. Manufactured by ABB - Installation Products, this joint is built to meet the demanding requirements of professional electrical installations, providing robust and dependable connections within medium voltage power distribution systems. The UNSPSC code for this product is 39121452.
  • 35kV rated power cable joint
  • Style 2 design with universal housing
  • Accommodates cable insulation diameter from 1.090" to 1.310"
  • Suitable for copper conductors: AWG Stranded 2/0 / Solid 3/0
  • Includes separate cable adapters and shield adapter

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
2/0 STR AWG , 3/0 SOL AWG
Connection
Compression
Enclosure
Yes
Environmental Conditions
Fully Insulated, Shielded and Sealed for Direct-Burial, Vault, Submersible and other Severe Service Applications
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
14-3/8 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Power Cable Joint
Voltage Rating
35 kV
Package Dimensions (L x W x H)
15.5 IN x 4.75 IN x 3.19 IN
Package Dimensions (L x W x H)
39.37 cm x 12.065 cm x 8.1026 cm
Package Weight (Imperial)
3.2500 L
Package Weight (Metric)
1.4740 kg
35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

35PCJ2L2250

35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

35PCJ2K1270-J1270

35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

35PCJ2J1240-H1240

35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Only, Housing Size N Bore Diameter at Jacket/Insulation Transition 1.390. Qatar.

69TCJN1-N-Q

69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Only, Housing Size N Bore Diameter at Jacket/Insulation Transition 1.390. Qatar.
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Only, Housing Size M - Bore Diameter at Jacket/Insulation Transition 1.258, Connector Type Copper, Connector Code 26P - Conductor Diameter Range - .450-.491 inch (11.43-12.47mm), Heatsink Bore N, Type Shield C - Copper Full Neutral Wire, Metallic Screen Continuity Kit A - 4/0 Bonding Cable, 6 foot quantity 1 with Split Bolts quantity 4. Armor Kit not required, Outer Jacket Restoration Kit - Heat Shrink

69TCJN1M226PNCANB

69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Only, Housing Size M - Bore Diameter at Jacket/Insulation Transition 1.258, Connector Type Copper, Connector Code 26P - Conductor Diameter Range - .450-.491 inch (11.43-12.47mm), Heatsink Bore N, Type Shield C - Copper Full Neutral Wire, Metallic Screen Continuity Kit A - 4/0 Bonding Cable, 6 foot quantity 1 with Split Bolts quantity 4. Armor Kit not required, Outer Jacket Restoration Kit - Heat Shrink
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Only, Housing Size M Bore Diameter at Jacket/Insulation Transition 1.258.

69TCJN1-M

69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Only, Housing Size M Bore Diameter at Jacket/Insulation Transition 1.258.
35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Stranded 750. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

35PCJ2P1380-M1330

35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Stranded 750. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.
46kV, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size M - Bore Diameter 1.258 inch, Insulation Range 1.435-1.675 inch, Connector Type - Copper, Conductor Code 27P - .492-.535 inch Diameter, Heatsink Size and Bore not Required, Type Shield B - Copper 1/3 Neutral Wire, Metallic Screen Continuity Kit M - Split Bolts quantity 4, Armour Kit Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.

46TCJN1M227PNBMNB

46kV, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size M - Bore Diameter 1.258 inch, Insulation Range 1.435-1.675 inch, Connector Type - Copper, Conductor Code 27P - .492-.535 inch Diameter, Heatsink Size and Bore not Required, Type Shield B - Copper 1/3 Neutral Wire, Metallic Screen Continuity Kit M - Split Bolts quantity 4, Armour Kit Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.

Frequently Asked Questions

Can copper connectors be used with aluminum conductors?

No, copper compression connectors are for copper-to-copper connections only. Do not use them on aluminum conductors.

What standards do PCJ joint shields and connectors meet?

The shield design meets IEEE 592 standard. Connectors meet ANSI 119.4 Class A and Class 3 ratings.

What is the maximum conductor size supported by PCJ joints?

Elastimold PCJ power cable joints can accommodate conductor sizes up to 1250 kcmil.

Where can Elastimold PCJ power cable joints be installed?

They are permanent, fully shielded, and submersible. Installation is suitable for direct-burial, underground vault, and overhead applications.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing similar cables. Style 2 uses adapters for transition splicing between different cable sizes.

What types of conductors are compatible with PCJ joints?

PCJ power cable joints work with copper or aluminum conductors, accommodating sizes up to 1250 kcmil.

What are the available voltage classes for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing similar cables. Style 2 uses adapters for transition splicing between different cable sizes.

Can copper connectors be used with aluminum conductors?

No, copper compression connectors are for copper-to-copper connections only. Do not use them on aluminum conductors.

What standards do PCJ joint shields and connectors meet?

The shield design meets IEEE 592 standard. Connectors meet ANSI 119.4 Class A and Class 3 ratings.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.