ABB Installation Products 25PCJ1H1220 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786631971
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 25kV rated power cable joint
- Style 1 single-piece housing
- Accommodates 0.850" to 1.050" cable insulation diameter
- Designed for aluminum conductors
- Supports AWG #2 stranded and AWG #1 solid conductors
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | #2 STR AWG , #1 SOL AWG |
Connection | Compression |
Connection Type | Cable Joint |
Insulation | Yes |
Material | EPDM Rubber |
Material | Aluminum Conductor, Single-Piece Housing |
Number Of Conductors | 2 |
Series | Style 1 |
Size | 14-3/8 inch long |
Size | 0.850-1.050 inch insulation diameter, AWG #2/#1 conductor |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.6800 L |
Package Weight (Metric) | 0.7620 kg |

25PCJ1G2220
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Conductor. Conductor Size AWG Stranded #2/Solid #1.
15PCJ1H1260
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 or Solid 4/0.
25PCJ1G1240-1220
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
25PCJ1H1250-1230
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
25PCJ1K1300
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.
25PCJ1L2320
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 450.
15PCJ1N1410Z
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Tin, Thin Walled, Connector
15PCJ1F1250-1220
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0/Solid 3/0. Conductor Size AWG Stranded #2/Solid #1.Frequently Asked Questions
What cable insulation diameters does this joint support?
This ABB 25kV Power Cable Joint supports cable insulation diameters ranging from 0.850 inches to 1.050 inches.
What conductor types is this joint compatible with?
This joint is designed for aluminum conductors, specifically AWG #2 stranded and AWG #1 solid conductor sizes.
What is the voltage rating of this ABB cable joint?
This ABB 25kV Power Cable Joint is rated for 25kV.
What is the housing style of this cable joint?
This ABB cable joint features a Style 1 single-piece housing.
How to Install the 15/25/35PCJ1WXXXX Straight Joint
This guide provides step-by-step instructions for the permanent installation of the 15/25/35PCJ1WXXXX straight joint, designed for wire shielded cables with aluminum or copper conductors. Ensure all safety precautions are followed for high voltage electrical equipment.
Estimated time: 2h
Tools needed:
Cable cutting tool, Cable stripping and preparation tools, Wire brush (for aluminum conductors), Crimping tool (for splice), Measuring tape or ruler, T&B WT3D cable tie tool (for 35kV installations)
Supplies needed:
Joint Housing (15/25/35PCJ1WXXXX), Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Appropriate connector (for grounding wires), DELTECt Cable ties (TYD5135, for 35kV installations), #14 AWG copper wire or equivalent (if shield wires are small), Cable jacket reconstruction material (if applicable)
- De-energize Apparatus and Inspect Components
Before beginning, ensure all apparatus in the work area are de-energized. Verify the joint housing, splice, lubricant, and all other components are complete, undamaged, and compatible with the cable and mating parts. Read all instructions thoroughly. DANGER: Failure to de-energize will result in serious or fatal injury. This product must be installed by competent personnel trained in high voltage safety practices.
- Prepare Cables for Joint Centerline
Overlap both cables and cut them to 12 inches (305mm) from the intended centerline of the joint. This ensures sufficient length for shield wires to rejoin. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires on both cables. Finally, cut both cables precisely at the joint centerline.
- Taper Cable 1 and Store Joint Housing
Taper the edge of Cable 1's insulation shield from 1/2 inch (13mm) to no greater than 1-1/2 inches (38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Carefully slide the joint housing onto Cable 1, pushing it back until it rests against the folded shield wires.
- Remove Cable Insulation and Shield
Carefully remove the cable insulation and then the insulation shield from both Cable 1 and Cable 2 according to the 'X' and 'Y' dimensions provided in the documentation for your specific conductor size. Exercise extreme caution to avoid cutting or nicking the cable insulation or conductor during this process. WARNING: DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR, as this can lead to product failure.
- Install and Crimp the Conductor Splice
If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Check the dimension against the 'Max Check Before' table in the documentation; if it exceeds, redo the assembly. Crimp the splice following the manufacturer's recommendations. Wipe off any excess inhibitor. Check the distance between cable insulations against the 'Max Check After' table; if it exceeds, redo the assembly. Remove any sharp protrusions or burrs generated during crimping and ensure all metal chips/filings are removed from the splice and joint assembly area.
- Lubricate Cables and Position Joint Housing
Clean the cables where indicated in the documentation. Lubricate the cables in the direction of the arrows, creating a build-up or ramp of lubricant at the edge of the insulation shield. Slide the joint housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield.
- Complete Grounding and Reconstruct Jacket
Retrain the shield wires and secure them to the ends of the joint as shown in the diagrams. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and the remaining shield wires using an appropriate connector. Finally, reconstruct the cable jacket (where applicable) over both cables and the joint housing.
- Install 35kV Cable Ties (Optional)
FOR 35kV ONLY: Install two DELTECt Cable ties (TYD5135) on each end of the cable entrance. Install the outer ties approximately 1/4 inch (6mm) from the edge of the splice, then install the second ties approximately 1/4 inch (6mm) from the first, ensuring an offset of the locking heads. Use the T&B WT3D tool (not included) to tighten and trim the ties. Remove and discard the yellow pin from the joint grounding eye.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.