- 15/25 kV, 200 Amp rating for medium voltage applications
- Integrated test point for safe voltage verification
- Accommodates cable insulation diameters from 1.09-1.31 inches (27.48-33.27 mm)
- Copper lug supports conductor sizes 270 - 4/0 Stranded/Compressed and 250 kcmil Solid/Compact
- Complete kit includes housing, lug, probe, V.D. cap, lubricant, and instructions
Specifications
Amperage Rating | 200 A |
Application | 15/25kV, 200 Amp Deadbreak Connector |
Color | Black |
Conductor Range | 4/0 STR/COMPR AWG , 250 kcmil |
Connection | Compression |
Environmental Conditions | Fully Submersible |
Insulation | True |
Length | 7.531 in |
Length | 191.2874 mm |
Material | Housing - EPDM-Rubber |
Special Features | Fully Shielded, fully Submersible Molded Rubber Housing. Provision for Hot Stick Operation. Non-Corrosive, Capacitive Test Point. Bonding/Grounding Wire |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Elbow Connector with Test Point |
Voltage Rating | 15 to 25 kV |
Width | 5.454 in |
Width | 138.5316 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

162LR-D5270-S
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
K655LR-H0220
600 Amp, 15/25 kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size AWG Compressed/Stranded #2 or Compacted/Solid #1 or mm2 Compact 35.
K655LR-F0260
600 Amp, 15/25 kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size AWG Compressed/Stranded 3/0 or Solid/Compact 4/0 or mm2 95.
252LR-A5200
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575-0.740 inches (14.61-18.80 mm), Bi-Metal Lug, Conductor Size 200 - #4 Stranded/Compressed, #3 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
252LR-E5240
15/25 kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.09-1.31 inches (27.48-33.27 mm), Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed, 2/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
K655ETP-J0290-DRG-S
25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 300 kcmil or Compacted Solid 350 kcmil. With Insulated Cap. Cold-Shrinkable Jacket Seal Included. No Test Point. Consists of Elbow Housing, Tap Plug, Insulated Cap, Cable Size Adapter, Compression Lug, Stud, Lubricant, Crimp Chart and Instructions
K655ETP-M0380-DRG-S
25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 700/750 kcmil or Compacted Solid 900 kcmil. With Insulated Cap. Cold-Shrinkable Jacket Seal Included. No Test Point. Consists of Elbow Housing, Tap Plug, Insulated Cap, Cable Size Adapter, Compression Lug, Stud, Lubricant, Crimp Chart and Instructions
756LR-J0300
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed Stranded 350 kcmil or Compacted Solid 400 kcmil or mmSquared Compact 185.Frequently Asked Questions
What is the product's voltage rating?
The product is rated for 15/25kV voltage classes. For 15kV, max phase-to-ground is 8.3kV; for 25kV, it's 15.2kV.
Where can I find installation instructions for concentric neutral cables?
For full installation instructions for concentric neutral cables, please refer to IS-459.
What adapter is used for Unishield cables?
For Unishield cables, use the 10TL-W shield adapter, where "W" is determined by the cable's insulation diameter, or add suffix "-TL" to the part number.
What sealing kit is used for copper tape shield cables?
For copper tape shield cables, use the 200ECS sealing and grounding kit or add suffix "-S" to the part number for cables with nominal O.D. between 0.80 in and 1.50 in.
What sealing kit is used for jacketed concentric neutral cables?
For jacketed concentric neutral cables, use the 200ECS sealing kit or add suffix "-S" to the part number for cables with nominal O.D. between 0.80 in and 1.50 in.
Is a sealing and grounding kit required?
A sealing and grounding kit is highly recommended for safety purposes with the deadbreak elbow.
What is the purpose of the 160CA cable adapter?
The 160CA adapter is for small cables with insulation OD between 0.495 in and 0.685 in, used with 165/166LR elbow size housings.
What if my cable's OD is less than 0.565 inches?
For cables with an OD less than 0.565 in, you must order cable adapter 160CA-XX.
What type of conductors are compatible with the lugs?
Bi-metal compression lugs are suitable for both copper and aluminum conductors. Copper lugs are only for copper conductors.
What is included in the connector kit?
The kit contains the elbow connector housing, a bi-metal compression lug, probe, probe wrench, bail assembly, lubricant, installation instructions, crimp chart, and V.D Cap-Peroxide.
How to Install 252LR Deadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe installation and initial setup of the 252LR Deadbreak Elbow Connector, designed for UD cable termination with concentric neutral and semi-con shielding. It includes cable preparation, elbow assembly, and connection to a 25kV class deadbreak bushing.
Estimated time: 1h 30m
Tools needed:
Wrench, Crimp tool, Wire brush, Cable cutting tool, Semi-con shield removal tool, Fully insulated hot stick
Supplies needed:
Elbow Connector Housing, Compression Lug, Probe, Probe Contact, Lubricant, Hold-down Bail, No. 14 AWG (2.5mm) copper wire, Grounding connector, HV insulated cap(s) or connector(s)
- Prepare for Installation and Inspect Components
Ensure all apparatus are de-energized before beginning installation. Verify the package contents are complete and undamaged. Check the elbow housing cable entrance size and compression lug size for proper fit with the cable. Thread the probe into the compression lug to check for damage; replace any damaged components if resistance is encountered. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before energizing the circuit.
- Train the Cable
Train the UD cable as shown in the diagram to ease operation. Cut any excess cable squarely at the center line of the bushing, ensuring a minimum of 20 inches (508.0mm) beyond the end of the cable pad mount transformer.
- Prepare the Cable End
Unwrap and bind the concentric neutral wires 8-1/2 inches (216.0mm) back from the end of the cable. Remove the shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating it to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe excessive inhibitor from the outside of the lug and cable. Remove the semi-con shield as shown in the template, then bevel the insulation end a maximum of 1/8 inch (3.2mm). Thoroughly clean the insulation to remove all traces of conductive residue.
- Assemble the Elbow Connector
Clean and lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back and forth twisting motion. Wipe off all excess silicone lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring not to cross-thread. Tighten the probe with the supplied wrench until the wrench bends.
- Install the Hold-down Bail
Place the hold-down bail into the hold-down bracket. Compress the bail and insert it securely into the brackets.
- Connect the Concentric Neutral
Using a separate No. 14 AWG (2.5mm) copper wire or equivalent, insert one end through the grounding eye on the elbow. Twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.
- Connect Elbow to Bushing
Clean the receptacle portion of the elbow connector and the mating bushing, then lubricate with the supplied lubricant ONLY if the transformer and elbow are known to be de-energized. Use a fully insulated hot stick to place the elbow onto the bushing. WARNING: Do not operate by hand. Do not separate if energized.
- Secure the Elbow with the Bail
Pull the hold-down bail up over the crown or top of the elbow so that the eyebolt on the bail is directly over the operating eye. Tighten down on the elbow locator by turning the eyebolt in a clockwise direction. Adjust the nut on the eyebolt until it allows the eyebolt to seat securely in the locator. The nut should act as a stop to prevent the eyebolt from applying excessive force on the elbow. Once the nut is in its final position, it will not need to be readjusted when removing and replacing the elbow.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.