ABB - Installation Products 168FLR1B5240 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 1/0 AWG Stranded/Compressed, 2/0 AWG Solid/Compact.

ABB Installation Products 168FLR1B5240 Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port…

UPC: 075114214896


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 168FLR1B5240 molded current limiting fuse housing is a compact, high-voltage solution designed for reliable electrical distribution systems. Engineered for 8.3kV nominal fuse voltage ratings, this housing ensures robust protection against overcurrent conditions while maintaining operational safety. The unit features two capacitive test ports, enabling quick and safe diagnostics of fuse status without system shutdown, reducing maintenance downtime. Its small footprint accommodates cable insulation diameters from 0.635 to 0.905 inches (16-23mm), making it versatile for various conductor configurations. The housing supports bi-metal conductors in 1/0 AWG stranded/compressed and 2/0 AWG solid/compact sizes, providing flexibility for different installation requirements. The 168FLR1B5240 is constructed with a molded design optimized for durability and precision, ensuring long-term performance in demanding environments. The capacitive test ports allow for non-intrusive voltage verification, enhancing safety during routine inspections. The bi-metal conductor compatibility supports both stranded and solid configurations, accommodating a wide range of cable types and installation methods. With a compact housing, it integrates seamlessly into existing electrical distribution systems, minimizing space requirements while maintaining high levels of protection. Designed for industrial, commercial, and utility applications, the 168FLR1B5240 provides a reliable solution for high-voltage protection where operational efficiency and diagnostic accessibility are critical. This integration supports streamlined system design and maintenance, reinforcing ABB’s commitment to safety and performance in electrical distribution.
  • Nominal fuse voltage rating: 8.3kV for high-voltage protection
  • Two capacitive test ports for safe, efficient fuse status diagnostics
  • Cable insulation diameter range: 0.635–0.905 inches (16–23mm)
  • Bi-metal conductor compatibility: 1/0 AWG stranded/compressed or 2/0 AWG solid/compact
  • Compact design for space-constrained electrical distribution applications

Specifications

Amperage Rating
200 A
Application
Protect Light Duty Underground Distribution Systems
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Insulation
True
Length
16.87 in
Length
428.498 mm
Material
Bi-Metal
Material
EPDM-Rubber
Series
168FLR1B
Size
Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm
Special Features
Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 15kV Loadbreak Elbow Switching
Standard
IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Fused Elbow Connector
Voltage Rating
8.3 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 1/0 AWG Stranded/Compressed, 2/0 AWG Solid/Compact.

168FLR3-C5240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 1/0 AWG Stranded/Compressed, 2/0 AWG Solid/Compact.
POWER TERMINALS TYPE 3 RENTAL

45030034

POWER TERMINALS TYPE 3 RENTAL
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Bi-Metal Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.

168AFLR1-A5240-S

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Bi-Metal Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1 AWG Stranded/Compressed, 1/0 AWG Solid/Compact. SG4 Option.

168FLR1-B0230-SG4

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1 AWG Stranded/Compressed, 1/0 AWG Solid/Compact. SG4 Option.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 2 AWG Solid/Compact.

168FLR3-A0210

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 2 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid/Compact.

168AFLR1-A0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 2 AWG Solid/Compact.

168AFLR1-A0210

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 2 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 4 AWG Stranded/Compressed

168FLR1A0200

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 4 AWG Stranded/Compressed

Frequently Asked Questions

What is the primary application of the 168FLR Fused Elbow?

It protects light duty underground distribution systems, including sub-loops and radial taps, by replacing existing 200 Amp loadbreak tap elbows.

Does the product provide an indication for a blown fuse?

Yes, it has built-in voltage test points for quick and convenient blown fuse indication.

What items are included in the 168FLR Fused Elbow kit?

The kit includes the elbow connector housing, crimp connector, probe lug, lubricant, installation instructions, and a crimp chart.

What types of conductors are compatible with the compression lugs?

Copper compression lugs are for copper conductors only. Bi-metal lugs are suitable for copper or aluminum conductors.

What are the available fuse sizes for Housing Code 1?

Housing Code 1 supports fuse sizes of 3-45A at 8.3kV and 6-20A at 15.5kV.

What industry standards does the 168FLR Fused Elbow meet?

It meets IEEE 386, ANSI C37.40, ANSI C37.41, and ANSI C37.47.

Is the 168FLR Fused Elbow suitable for submersible applications?

Yes, the 168FLR Fused Elbow is fully sealed and submersible.

What is the current rating range for the fuses?

The current rating for the fuses ranges from 3 to 80 Amps.

What is the symmetrical interrupting capability of the product?

The product has a symmetrical interrupting capability of 50,000 Amps.

What is the nominal and maximum rated fuse voltage?

The nominal fuse voltage is 8.3kV, and the maximum rated fuse voltage is 10kV.

How to Install the 168FLR Loadbreak Fused Elbow Connector

This guide provides step-by-step instructions for the safe installation and assembly of the 168FLR Loadbreak Fused Elbow Connector, including cable preparation, component assembly, and final connection to a bushing.

Estimated time: 2h

Tools needed:

Wire strippers, Wire brush, Crimp tool, Torque limiting Allen wrench, Probe wrench, Hotstick

Supplies needed:

168FLR Loadbreak Fused Elbow Connector kit, UD cable (concentric neutral, extruded insulation shielding), Optional 200ECS Cold Shrink Cable Seal, No. 14 AWG (2.5mm) copper wire, Appropriate grounding connector, HV insulated cap(s) or connector(s)

  1. Prepare Cable and Components

    DANGER: Ensure all apparatus is de-energized before beginning installation. Inspect all components for damage, proper rating, and compatibility. Using the bushing centerline as reference, cut excess cable and remove the cable jacket and insulation shield according to the provided diagram (A + 7-3/8 inches from bushing centerline, then 5-1/2 inches from lug end). Squarely cut 1-1/8 inches from the cable end, taking care not to nick the conductor. Wire brush bare aluminum conductors and immediately crimp the compression lug, rotating 180 degrees for successive crimps. Clean insulation thoroughly.

  2. Assemble Cable Half with Fuse and Probe Connector

    Apply the supplied lubricant to the outside of the connector, cable insulation, conductive shield, and the cable half's entrance end. Insert the connector and cable into the cable half of the Fused Elbow until the connector protrudes beyond surface 'A'. Insert the threaded end of the fuse into the cable half and hand-tighten it into the cable connector. CAUTION: Do not over-torque the fuse stud. Pull the housing up against the tightened fuse. Assemble the probe connector to the fuse terminal, orienting the flats perpendicular to the mating bushing, then tighten the setscrews using the supplied torque-limiting Allen wrench. Rotate the cable half so its test point is perpendicular to the probe connector flats.

  3. Complete Elbow Assembly and Neutral Connection

    Apply lubricant to the elbow half and assemble it to the cable half, ensuring a 3/4-inch overlap and that the probe connector faces the elbow half's opening, with both test points aligned. Insert the probe into the probe connector, pushing the cable to align if needed. Hand-start threads, then tighten using the supplied torque-limiting Allen wrench until it bends. Position and tighten the hose clamp, but do not overtighten. Connect a No. 14 AWG copper wire through each grounding eye on the elbow and cable housings, twisting tightly. Twist all neutral wires and connect them to ground using an appropriate connector, providing adequate slack for operation.

  4. Final Connection to Bushing

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. DANGER: Only lubricate if the transformer and elbow are known to be de-energized. Use a full insulated hotstick tool to connect the elbow to the bushing, following operating instructions for energized connections. Do not operate by hand.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.