Overview
- 15kV, 200 Amp loadbreak rated insulated cap with integrated ground lead
- Meets ANSI/IEEE Standard 386 for 15kV class systems
- Fully shielded, submersible, and hot stick operable design
- Molded EPDM rubber construction with #14 AWG ground lead wire
- Compatible with Elastimold® 1601A4, 164FT, 1602A3R, and 164 series junctions
Specifications
Application | 15 kV, 200 Amps |
Current Rating | 200 A |
Material | Insulated |
Series | 160DRGA |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Insulated Cap |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0900 L |
Package Weight (Metric) | 0.4940 kg |

K675TBC
15/25kV, 900 Amp, Deadbreak Bushing for In-Air Applications (Pad-Mounted or Vault-Type or Submersible Transformers or Switchgear). One Factory installed 5/8-11 UNC-2A Stud included, other Stud must be Purchased Separately. Overall Length 13.75 inch, Diameter 4.50 inch. Molded Epoxy with Stainless Steel Flange. Boot and Collar.
138-366-6-18
TCJ (Transmission Cable Joint) Heat Sink Housing, Outside Diameter 3.25 inch, Bore Diameter 1.859 inch.
160-143-2 TIN
Tin Plated Copper Spade Type Contact, Length 2-1/8 inch, Outside Diameter .696 inch. Cable Size 2/0 AWG. 1-Hole 3/8-16 UNC-2B Tapped
164J4-5 PREPACK
200 Amp, 15kV, 4-Point Junction with U straps, Contains Instruction Sheet, Bottom Shield Plate, U-Strap, Hardware Pack and Lubricant.Frequently Asked Questions
What items are included in the 160DRG kit?
Each 160DRG kit contains one insulated cap, one 82-08 lubricant, and one IS-0892 installation instruction.
What is the 160DRG insulated cap used for?
The 160DRG insulated cap is a fully shielded, submersible connector designed for energized operation on 15kV class loadbreak systems. It is used to "dead-end" specific Elastimold® mating products.
What is the voltage class of the 160DRG cap?
The 160DRG insulated cap is designed for the 15kV voltage class.
What is the maximum operating voltage for the 160DRG?
The maximum phase-to-ground operating voltage for the 160DRG is 8.3kV. The maximum phase-to-phase voltage is 14.4kV.
What is the continuous current rating of the 160DRG?
The 160DRG insulated cap has a continuous and loadbreak current rating of 200 Amps.
Which Elastimold products are compatible with the 160DRG?
The 160DRG is compatible with Elastimold® 1601A4 bushing inserts, 164FT feed thrus, 1602A3R feed-thru inserts, and 164 series junctions.
What material is the 160DRG cap made from?
The 160DRG insulated cap is made from molded EPDM Rubber.
Does the 160DRG cap include a ground lead?
Yes, the 160DRG insulated cap includes an integral #14 AWG ground lead wire as part of the assembly.
Is the 160DRG designed for hotstick operation?
Yes, the 160DRG insulated cap is hot stick operable and includes a provision for hotstick operation.
What are the withstand voltage ratings for the 160DRG?
The 160DRG has a 95kV BIL impulse withstand, 34kV AC one-minute withstand, and 53kV DC 15-minute withstand.
How to Install the 160DRGA(3) Insulated Cap with Ground Lead
Instructions for installing and removing the 160DRGA(3) insulated cap with ground lead on a loadbreak bushing interface.
Estimated time: 30m
Tools needed:
Hotstick, Screwdriver
Supplies needed:
Insulated Cap with Ground Lead, Lubricant, Mounting screws
- Connect the electrostatic grounding wire
Connect the free end of the electrostatic grounding wire to the system ground. Ensure there is enough slack for hot-stick operation of the insulated cap. The grounding wire should not contact the bushing interface during operation. WARNING: If the ground lead disconnects during operation, do not attempt to reattach without first pulling the insulated cap off the bushing with the hotstick.
- Prepare the insulated cap
Remove the protective cover from the insulated cap. Lubricate the cap's internal mating surface using only the supplied lubricant or ELASTIMOLD approved lubricants. Keep the internal mating surface free from dirt and grime. Always replace the protective cover when not in use.
- Install the insulated cap
Firmly attach the hotstick to the insulated cap's pulling eye. Insert the male contact of the insulated cap into the loadbreak bushing. Push home with a fast, firm, straight motion, ensuring it is fully mated and the locking ring is seated. Detach the hotstick from the insulated cap.
- Remove the insulated cap
Attach the hotstick to the pulling eye. Before pulling, rotate the insulated cap clockwise while in the mated position to break surface friction. Pull the receptacle off with a fast, firm, straight motion. Remove the electrostatic grounding wire of the insulated cap from the system ground. Replace the protective cover on the insulated cap.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.