Authorized ABB Distributor (Installation Products)
ABB - Installation Products 152-EA-HAB - 200 Amp, 15/25kV, Deadbreak Cable Entrance Insulating Plug, Cable Insulation Diameter 1.040 inch to 1.175 inch.

ABB Installation Products 152-EA-HAB 200 Amp, 15/25kV, Deadbreak Cable Entrance Insulating Plug, Cable Insulation Diameter…

UPC: 075114143950


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 152-EA-HAB Deadbreak Cable Entrance Insulating Plug is designed for reliable electrical connections in medium-voltage applications. Rated for 200 Amps and suitable for 15kV and 25kV systems, this plug ensures safe and effective termination of power cables. Its construction accommodates cable insulation diameters ranging from 1.040 inches to 1.175 inches, providing a secure fit for specified cable sizes. The deadbreak design facilitates safe disconnection under load, a critical feature for operational safety and maintenance efficiency in power distribution networks. Manufactured by ABB - Installation Products, this component adheres to stringent industry standards for insulating plugs. Its primary function is to provide a robust and insulated interface for deadbreak connectors, preventing electrical discharge and ensuring personnel safety. The SKU 152-EA-HAB identifies this specific model within ABB's extensive catalog of electrical infrastructure solutions. This insulating plug is essential for substations, industrial facilities, and utility power distribution systems where reliable and safe cable terminations are paramount. Its precise fit for the specified insulation diameter range minimizes air ingress and moisture contamination, contributing to the longevity and performance of the electrical system.
  • 200 Amp current rating
  • Suitable for 15kV and 25kV systems
  • Accommodates cable insulation diameters from 1.040" to 1.175"
  • Deadbreak cable entrance design for safe disconnection
  • Manufactured by ABB - Installation Products (SKU: 152-EA-HAB)

Specifications

Application
The ELASTIMOLD 152EA cable entrance insulating plug is designed to electrically insulate and water seal the cable entrances of the following ELASTIMOLD products: K151SP straight plug and K151SR straight receptacle
Connection Type
Deadbreak Cable Entrance
Current Rating
200 A
Material
Insulating
Series
152-EA-HAB
Size
Cable Insulation Diameter 1.040 inch to 1.175 inch
Size
1.040 inch to 1.175 inch
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Cable Entrance Insulating Plug
Voltage Rating
15/25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15/25kV, T-Splice 6-3/4 inch Long Bail Assembly, Made of Stainless Steel, Used for Assisting Cable to Transformer Connections. Non-Current Carrying. The 150TB2 bailing assembly kit consists of a modified hold down bail for securing Elastimold® tee splice K150T to a K150DP Deadbreak insulating plug. This assembly provides positive hold down force between the tee splice and the insulating plug.

150-TB-2

15/25kV, T-Splice 6-3/4 inch Long Bail Assembly, Made of Stainless Steel, Used for Assisting Cable to Transformer Connections. Non-Current Carrying. The 150TB2 bailing assembly kit consists of a modified hold down bail for securing Elastimold® tee splice K150T to a K150DP Deadbreak insulating plug. This assembly provides positive hold down force between the tee splice and the insulating plug.
HMI door mounting kit with 15M cable

181B2258

HMI door mounting kit with 15M cable
Polarizing Cover / Hermaphroditic Cover, Black, Nylon, 8 Position, AMPMODU IV/V

103350-4

Polarizing Cover / Hermaphroditic Cover, Black, Nylon, 8 Position, AMPMODU IV/V
200 Amp, 15kV, Insulated Cap with Ground, without Probe, Equipped with Insulated Cuff.

167DRGA

200 Amp, 15kV, Insulated Cap with Ground, without Probe, Equipped with Insulated Cuff.
200 Amp, 15kV, Brackets and hardware only for 164FT (Feed-Thru). Kit Includes Universal Bracket, Bottom Shield Plate, Flat-Head Machine Screws and Instruction Sheet.

164FT-6

200 Amp, 15kV, Brackets and hardware only for 164FT (Feed-Thru). Kit Includes Universal Bracket, Bottom Shield Plate, Flat-Head Machine Screws and Instruction Sheet.
Load Break Parking Stand, Hot Dip Galvanized Steel support for bushing connector. 2.75 inch high x 2.75 inch wide x 1.031 deep on bottom edge (.75 inch deep on top edge). 2 inch wide round bottom slot stops 3/8 inch from bottom edge.

160-PS-H

Load Break Parking Stand, Hot Dip Galvanized Steel support for bushing connector. 2.75 inch high x 2.75 inch wide x 1.031 deep on bottom edge (.75 inch deep on top edge). 2 inch wide round bottom slot stops 3/8 inch from bottom edge.
15/25kV 200 Amp, Deadbreak Cable Entrance Insulating Plug, Cable Insulation Diameter 0.610 inch to 0.735 inch.

152-EA-FAB

15/25kV 200 Amp, Deadbreak Cable Entrance Insulating Plug, Cable Insulation Diameter 0.610 inch to 0.735 inch.
15/25kV 200 Amp, Deadbreak Cable Entrance Insulating Plug, Cable Insulation Diameter 0.725 inch to 0.835 inch.

152-EA-FG

15/25kV 200 Amp, Deadbreak Cable Entrance Insulating Plug, Cable Insulation Diameter 0.725 inch to 0.835 inch.

Frequently Asked Questions

What is the cable insulation diameter range for HA code?

For the HA code, the cable insulation diameter range is 0.980 - 1.115 inches.

What is the cable insulation diameter range for EB code?

For the EB code, the cable insulation diameter range is 0.495 - 0.585 inches.

What cable entrance sizes are compatible with 152EA?

The 152EA is available for Elastimold connector cable entrance sizes EB, EF, FA, FAB, FB, FG, GA, GAB, GB, GH, and HA.

What is included when ordering the 152EA-W plug?

The 152EA-W cable entrance insulating plug includes one insulated plug (152EA-W), one lubricant (82-08), and one installation instruction (IS-0347).

How do I order the 152EA cable entrance insulating plug?

To order the cable entrance insulating plug, specify the number 152EA-W.

Which ELASTIMOLD products are compatible with 152EA?

The 152EA insulating plug is compatible with ELASTIMOLD K151SP straight plugs and K151SR straight receptacles.

What is the 152EA-W insulating plug used for?

The ELASTIMOLD 152EA cable entrance insulating plug is designed to electrically insulate and water seal cable entrances. It provides an electrically and mechanically sound dead-end cable entrance.

What is the cable insulation diameter range for HA code?

For the HA code, the cable insulation diameter range is 0.980 - 1.115 inches.

What is the cable insulation diameter range for EB code?

For the EB code, the cable insulation diameter range is 0.495 - 0.585 inches.

What cable entrance sizes are compatible with 152EA?

The 152EA is available for Elastimold connector cable entrance sizes EB, EF, FA, FAB, FB, FG, GA, GAB, GB, GH, and HA.

How to Install the 152EA Deadbreak Cable Entrance Insulating Plug

This guide provides instructions for safely installing the 152EA Deadbreak Cable Entrance Insulating Plug into an Elastimold product cable entrance, ensuring proper insulation and fit.

Estimated time: 15m

Tools needed:

Nylon Venting Rod

Supplies needed:

152EA Deadbreak Cable Entrance Insulating Plug, Lubricant (Do Not Substitute)

  1. Perform Pre-Installation Checks and Safety Measures

    Before beginning, ensure all apparatus is de-energized. Verify that the 152EA insulating plug and the product cable entrance (e.g., Elastimold 25S, 25Y, 1601CL) are compatible and correctly sized. Inspect all parts for damage and ensure the package contents are complete. Read all instructions thoroughly and have all required tools and supplies ready. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices.

  2. Lubricate the Insulating Plug

    Lightly lubricate the cable entrance insulating plug for a distance of approximately 5 inches from its chamfered end. Use only the supplied lubricant; do not substitute, as other lubricants may be harmful to this product and its mating product(s). Keep the insulating plug clean at all times.

  3. Insert the Insulating Plug into Cable Entrance

    If required, insert the nylon venting rod approximately 6 inches into the product cable entrance. Using a twisting motion, push the lubricated insulating plug into the product cable entrance until 1 inch remains protruding from the end. Remove the nylon venting rod (if used) and carefully wipe off any excess lubricant. Ensure the plug is firmly seated.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.