Overview
- 200 Amp, 15/25kV rated for medium-voltage applications
- Designed for #4 wire size connections in ABB switchgear
- Auxiliary contacts: 2 2 (Type: MCRI-0-22-AT-D)
- Compact design for installation in confined spaces
- High-conductivity materials for minimal power loss and heat generation
Specifications
Application | 15/25 kV, 200 Amps |
Current Rating | 200 A |
Size | #4 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Straight Replacement Contact |
Voltage Rating | 15/25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.1100 L |
Package Weight (Metric) | 0.0500 kg |

K650RTW
15/25kV 600 Series Deadbreak Reducing Tap Well. Length 5.37 inch. Width 3 inch not counting bracket. 600/200 Amps
675BLR-K5320
900 Amp, Connector, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.How to Install the 151SR/K151SR Straight Receptacle
This guide provides detailed instructions for the safe and proper installation of the 151SR/K151SR Straight Receptacle, designed for connecting solid dielectric type cables to other Elastimold products or electrical apparatus.
Estimated time: 1h
Tools needed:
Cable cutting tool, Wire strippers, Wire brush, Crimping tool, Rag
Supplies needed:
151SR/K151SR Straight Receptacle, Conductor Contact (male), Nylon Venting Rod, Lubricant (supplied), Crimp Chart, Approved solvent, Elastimold bail, Copper wire (#14 AWG or equivalent), Sealing material
- Perform Pre-Installation Checks and Safety Measures
Ensure all apparatus are de-energized before beginning installation. Inspect all parts for damage, correct rating, and compatibility with mating products. Gather all required tools and maintain a clean work environment throughout the procedure. If the product has protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before energizing or submerging the circuit.
- Prepare Cable Jacket
For jacketed concentric neutral cables, cut and remove 8 inches of the cable jacket from the end, ensuring sufficient neutral wires for grounding. For copper tape shield cables, cut and remove 7 1/2 inches of the cable jacket, then remove the copper tape shield 6 1/2 inches from the cable end. Refer to specific grounding device instructions if using an ECS or MA device for outer jacket cut back.
- Prepare Cable Insulation and Conductor
Remove 7/8 to 1 inch of cable insulation and conductive shield. For #1 stranded/compressed and #1/0 compressed/solid aluminum cable, remove 1 3/4 to 1 7/8 inches. Wire brush bare aluminum conductors immediately. Cut the conductor squarely; do not pencil the cut.
- Crimp Conductor Contact
Insert the bared conductor fully into the crimp barrel, which contains an inhibitor. Crimp the socket terminal onto the conductor following the supplied crimp chart. Start crimps at the imprinted crimp line and rotate each successive crimp 90 degrees. If using aluminum cable, carefully wipe any excess inhibitor from the contact and cable insulation.
- Prepare Semi-Conductive Shield and Clean Insulation
Remove the semi-conductive shield to a point 7 9/16 to 7 5/8 inches back from the end of the pin using a straight, smooth, 'squared' cut, taking care not to cut or nick the insulation. Pencil the insulation 1/8 inch. Thoroughly clean the outer jacket and insulation with an approved solvent to remove all traces of semi-conducting residue, wiping from the cable end towards the outer jacket. If using an ECS or MA grounding device, install it now per its instructions.
- Lubricate Cable and Receptacle Housing
Remove the protective cap from the straight receptacle, keeping the cable insulation and receptacle clean. Apply the supplied lubricant sparingly to the cable and to the inside of the receptacle housing. Do not substitute lubricants, as other types may harm the product or its mating part.
- Insert Cable into Receptacle Housing
Push the prepared cable into the receptacle housing until the base of the pin chamfer is flush with the inside face of the receptacle. If the receptacle will not be immediately connected, replace the protective cover (note: the shipping cover is for dirt protection only and is not an insulating device; use an Elastimold insulating plug K150DP if insulation is required).
- Connect to Mating Plug
Lubricate the nose of the mating plug with silicone grease. Insert the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches), ensuring the rod is not cut. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection using an Elastimold bail.
- Ground the Cable
If an ELASTIMOLD grounding device is not being used, connect a length of customer-supplied #14 AWG (or equivalent) copper wire through the grounding tab and twist tightly. Connect the grounding assembly of the connector to the system ground by merging it with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.