Overview
- 15-35kV voltage rating with 200 Amp current capacity
- Bi-metal construction with copper tip and aluminum crimp barrel
- Compatible with #3 stranded/compressed or #2 solid/compact conductors
- 2.88-inch length (Size Code 210) for extended contact surface
- Designed for use with 161/162LR, 261/262LR, 375/376LR, and 252LR elbows
Specifications
Amperage Rating | 200 A |
Cable Size | #3 STR AWG , #3 COMPR AWG , #2 SOL AWG |
Color | Bare |
Connection | Compression |
Connection Type | #3 Stranded/Compressed or #2 Solid/Compact |
Current Rating | 200 A |
Environmental Conditions | Must be Protected/installed into Elbow Connector, Repair Elbow Connector or Replacement Elbow |
Insulation | None |
Material | Bi-Metal |
Material | Bi-Metal (Aluminum and Copper) |
Number Of Holes | 1 |
Series | Loadbreak LR Long |
Size | Size Code 210 |
Standard | IEEE 386 |
Stud Size | 3/8 Inch |
Type | Bi-Metal Contact Compression Lug |
Voltage Rating | 15-35 kV |
Voltage Rating | 15-35kV |
Voltage Rating | 15 to 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.1500 L |
Package Weight (Metric) | 0.0680 kg |

13682
Die for 12 Ton 13400 or 13642M Hydrualic Tool for Crimping 204210MT Dragon Tooth Terminals, Brown. .301/.289 Gaging
RDC1/0
Ratchet Drive Crimping Tool APPLICATIONS: Ratchet Drive Crimping Tool is for non-insulated terminals from 6 to 1/0 AWG and insulated terminals from 22 to 8 AWG. Rugged, compact, and lightweight. Requires minimum effort due to ratchet action, ensuring an excellent crimp every time. FEATURES: TYPE: Insulated and Uninsulated ACTION: Ratchet INSULATED USE: Terminals 22 to 8 AWG NON-INSULATED USE: Terminals 6 to 1/0 AWG MANUFACTURER: NSi Industries PART NUMBER: RDC 1/0 UPC: 662381055309
CD6A
U-Type Compression Die - Pink 1/0 AWG Copper - 2 AWG Aluminum U-Shaped Compression Dies are for use with the NSi-12 Compression Tool and Other Tools. See Cross-Reference Chart below.
F4-PS-W-NP
Non-Insulated Parallel Splice Connector For Wire Range #4 AWG, Circular Mil Range 33,100-52,600, Length 0.531 Diameter 0.41, Nickel Plated
AS-K1-H6
Power Distribution Block (1) 2/0-14 AWG Primary (6) 4-14 AWG Secondary Power Distribution Blocks are made of high strength, high-conductivity aluminum alloy and are mounted in a high-strength glass-filled polyester base. Each block can stand alone or combine with other blocks to form a multi-block set.
1SNK705010R0000
Combine high performance with compact dimensions: - 1000 V AC / DC IEC 600 V UL, - Opt for the best marking visibility thanks to the up-front, flat marker zone, which lets you mark up to eight digits or increase the font size.
1SNK705030R0000
Combine high performance with compact dimensions: - 1000 V AC / DC IEC 600 V UL, - Opt for the best marking visibility thanks to the up-front, flat marker zone, which lets you mark up to eight digits or increase the font size.
E989NNJ-5-HD
Molded Junction Box, Length 4 Inch x Width 4 Inch x Depth 2 Inch, Material Polycarbonate, Color GrayFrequently Asked Questions
What items are included in each 02500XXX connector kit?
Each 02500XXX kit contains one 02500XXX connector and one Crimp Chart CC-0020.
What conductor sizes does the 02500210 connector support?
The 02500210 connector supports #3 AWG or kcmil for stranded/compressed conductors and #2 AWG or kcmil for solid/compressed bi-metal conductors.
What items are included in each 02500XXX connector kit?
Each 02500XXX kit contains one 02500XXX connector and one Crimp Chart CC-0020.
What conductor sizes does the 02500210 connector support?
The 02500210 connector supports #3 AWG or kcmil for stranded/compressed conductors and #2 AWG or kcmil for solid/compressed bi-metal conductors.
What conductor sizes does the 02500210 connector support?
The 02500210 connector supports #3 AWG or kcmil for stranded/compressed conductors and #2 AWG or kcmil for solid/compressed bi-metal conductors.
What items are included in each 02500XXX connector kit?
Each 02500XXX kit contains one 02500XXX connector and one Crimp Chart CC-0020.
What conductor sizes does the 02500210 connector support?
The 02500210 connector supports #3 AWG or kcmil for stranded/compressed conductors and #2 AWG or kcmil for solid/compressed bi-metal conductors.
What items are included in each 02500XXX connector kit?
Each 02500XXX kit contains one 02500XXX connector and one Crimp Chart CC-0020.
What items are included in each 02500XXX connector kit?
Each 02500XXX kit contains one 02500XXX connector and one Crimp Chart CC-0020.
What conductor sizes does the 02500210 connector support?
The 02500210 connector supports #3 AWG or kcmil for stranded/compressed conductors and #2 AWG or kcmil for solid/compressed bi-metal conductors.
How to Install 252LR Deadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe installation and wiring of 252LR Deadbreak Elbow Connectors on UD cable, connecting them to a 25kV class deadbreak bushing or accessory device.
Estimated time: 1h 30m
Tools needed:
Wrench, Wire brush, Crimp tool, Wire strippers, Hot stick (fully insulated), Cable cutter
Supplies needed:
Elbow Connector Housing, Compression Lug, Probe, Probe Contact, Lubricant, Hold-down Bail, UD cable (concentric neutral and semi-con shielding), No. 14 AWG (2.5mm) copper wire, Appropriate connector (for neutral wires), Bushing (mating part), Test point cap (if not pre-installed)
- Prepare for Installation and Safety Checks
Ensure all apparatus is de-energized before beginning installation or removal of any parts. Inspect all components (Elbow Connector Housing, Compression Lug, Probe, Probe Contact, Hold-down Bail) for damage, correct rating, and compatibility with mating parts. Verify the elbow housing cable entrance size and compression lug size are appropriate for the cable. Check the probe threads by hand-threading it into the compression lug; if resistance is encountered, check for damage and replace the component. If the test point cap is not installed, lubricate it with the supplied lubricant and install it on the test point. Have all required tools at hand and maintain cleanliness throughout the procedure.
- Train and Cut the Cable
Train the UD cable to ease operation, ensuring a minimum of 20 inches (508.0mm) extends beyond the end of the cable pad mount transformer. Cut the excess cable squarely at the center line of the bushing.
- Prepare Cable for Lug Installation
Unwrap and bind the concentric neutral wires 8-1/2 inches (216.0mm) back from the end of the cable. Remove the shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush the bare aluminum conductors thoroughly and immediately install the compression lug, rotating it to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the manufacturer's chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable. Remove the semi-con shield as shown in the diagram and bevel the insulation end a maximum of 1/8 inch (3.2mm). Thoroughly clean the insulation to remove all traces of conductive residue.
- Install Elbow Housing and Probe
Clean and lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute other lubricants. Slide the elbow connector onto the cable using a back and forth twisting motion, then wipe off all excess silicone lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread, and tighten with the supplied wrench until the wrench bends.
- Ground Concentric Neutral Wires
Using a separate No. 14 AWG (2.5mm) copper wire or equivalent, insert one end through the grounding eye on the elbow and twist tightly, ensuring not to damage the eye. Twist all concentric neutral wires together and connect them to ground using an appropriate connector, providing adequate slack in the wires for elbow operation.
- Connect Elbow to Mating Bushing
Clean the receptacle portion of the elbow connector and the mating bushing, and lubricate with the supplied lubricant. IMPORTANT: Only lubricate if the transformer and elbow are known to be de-energized. Use a fully insulated hot stick to place the elbow onto the bushing. DO NOT OPERATE BY HAND. DO NOT SEPARATE IF ENERGIZED.
- Secure Elbow with Hold-down Bail
Pull the hold-down bail up over the crown or top of the elbow so that the eyebolt on the bail is directly over the operating eye. Tighten down on the elbow locator by turning the eyebolt in a clockwise direction. Adjust the nut on the eyebolt until it allows the eyebolt to seat securely in the locator, acting as a stop to prevent the eyebolt from applying excessive force on the elbow.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.