Showing 8677-8688 of 12,986 results

The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 63 amps D02 shipbuilding 1 pole fuse base with dual terminals .
Contact for Pricing
Minimum Qty: 20
Multiplier: 20
*Contact for lower quantities*

DIN D0 Fuse-link Neozed gG Size D02 440VAC 250VDC 50A Color code White Packaging quantity 50
Contact for Pricing
Minimum Qty: 50
Multiplier: 50
*Contact for lower quantities*

DIN D0 Fuse-link Neozed gG Size D02 440VAC 250VDC 35A Color code Black Packaging quantity 50
Contact for Pricing
Minimum Qty: 50
Multiplier: 50
*Contact for lower quantities*

DIN D0 Fuse-link Neozed gG Size D02 400VAC 250VDC 50A Color code White Packaging quantity 50
Contact for Pricing
Minimum Qty: 50
Multiplier: 50
*Contact for lower quantities*

The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 63 amps D02 shipbuilding 3 pole fuse base with dual terminals .
Contact for Pricing
Minimum Qty: 5
Multiplier: 5
*Contact for lower quantities*

The D fuse-system is the first generation of screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D fuse range comprises the sizes NDZ, DII, DIII, DIV, DV. The range of applications for D fuse-links is the protection of cables and power lines. They limit and cut-off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 500 Volts 25 amps DIII gray screw cap .
Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*

DIN Fuse base Neozed Size D03 400VAC 100A 1-Pole with touch prot. Screw mounting Clamp Strap / Screw
Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*

The universal bus bar carrier is designed for bus bars with thickness of 5 mm or 10 mm retaining unchanged height of supporting edge without use of additional accessories (distance pieces). The 2-hole fixing and 4-hole fixing modular system concept provides the carrier for use in distribution units with central cover and for installation on to subplates. dual adapter, no wiring
Contact for Pricing

DIN NH Standard fuse-link aM Size NH4 500VAC 1250A live tags Top indicator Body width 100.10 mm
Contact for Pricing

DIN D0 Fuse-link Neozed gG Size D02 400VAC 250VDC 35A Color code Black Packaging quantity 50
Contact for Pricing
Minimum Qty: 50
Multiplier: 50
*Contact for lower quantities*

The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 100 amps D03 1 pole cover .
Contact for Pricing
Minimum Qty: 40
Multiplier: 40
*Contact for lower quantities*

The D fuse-system is the first generation of screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D fuse range comprises the sizes NDZ, DII, DIII, DIV, DV. The range of applications for D fuse-links is the protection of cables and power lines. They limit and cut-off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 500 Volts 25 amps DII gray screw cap .
Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*