Showing 5125-5136 of 12,986 results

Fuse supports, non-disconnecting, are used primarily in potential transformer circuits, or where there is some other disconnecting or isolating device in series with the fuse in the circuit. Disconnecting switch devices have the additional feature of serving to isolate the equipment they protect. It should be noted that disconnecting switches are not load-breaking devices, therefore, the circuit must be open prior to the fuse disconnection. Select either a fuse support or a disconnecting switch for each fuse. Fuse supports and disconnecting switches include live parts for both ends. Both fuse supports and fuse disconnect switches can be mounted vertically or horizontally. The type EK are used for indoor installations while the type EKO are used outdoors. 25800 Volts EKO-1D CHM series.
Contact for Pricing

Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 600 Volts PV system type .
Contact for Pricing

Mersen's patented TPMOV® (Thermally Protected Metal Oxide Varistor ) eliminates common destructive failure modes associated with standard MOVs. Comprised of a voltage clamping device and a disconnecting apparatus that monitors the status of the metal oxide disk inside the TPMOV, the device is securely disconnected in the event of an overvoltage by an arc shield. Upon failure, the TPMOV is also equipped with a visual pin indicator as well as a normally open microswitch providing remote indication, if applicable. 320 Volts Micro and Short Leads series.
Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*

Fuse supports, non-disconnecting, are used primarily in potential transformer circuits, or where there is some other disconnecting or isolating device in series with the fuse in the circuit. Disconnecting switch devices have the additional feature of serving to isolate the equipment they protect. It should be noted that disconnecting switches are not load-breaking devices, therefore, the circuit must be open prior to the fuse disconnection. Select either a fuse support or a disconnecting switch for each fuse. Fuse supports and disconnecting switches include live parts for both ends. Both fuse supports and fuse disconnect switches can be mounted vertically or horizontally. The type EK are used for indoor installations while the type EKO are used outdoors. 15500 Volts EK-3C AGJ series.
Contact for Pricing

Contact for Pricing

Mersen's patented TPMOV® (Thermally Protected Metal Oxide Varistor ) eliminates common destructive failure modes associated with standard MOVs. Comprised of a voltage clamping device and a disconnecting apparatus that monitors the status of the metal oxide disk inside the TPMOV, the device is securely disconnected in the event of an overvoltage by an arc shield. Upon failure, the TPMOV is also equipped with a visual pin indicator as well as a normally open microswitch providing remote indication, if applicable. 550 Volts Micro and Short Leads series.
Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*

Medium Voltage E-Rated Fuse 2750VAC 1A Ferrule, Series: CCB Visual Indicator
Contact for Pricing

Contact for Pricing

Medium Voltage E-Rated Fuse 2750VAC 125A Ferrule, Series: HJB Visual Indicator
Contact for Pricing

Back-Up R-Rated Medium Voltage Fuse 5080VAC 2R Mounting: Ferrule Style: LJN Amp-Trap®
Contact for Pricing

Fuse supports, non-disconnecting, are used primarily in potential transformer circuits, or where there is some other disconnecting or isolating device in series with the fuse in the circuit. Disconnecting switch devices have the additional feature of serving to isolate the equipment they protect. It should be noted that disconnecting switches are not load-breaking devices, therefore, the circuit must be open prior to the fuse disconnection. Select either a fuse support or a disconnecting switch for each fuse. Fuse supports and disconnecting switches include live parts for both ends. Both fuse supports and fuse disconnect switches can be mounted vertically or horizontally. The type EK are used for indoor installations while the type EKO are used outdoors. 25800 Volts EKO-3C CHM series.
Contact for Pricing

Contact for Pricing