Accessories

    Office Equipment and Accessories and Supplies

    Drives, Servos, and Motors

    Power Generation and Distribution Machinery and Accessories

    Structures, Building, and Construction

    Enclosures, Fans, and Environmental Controls

    Information Technology Broadcasting and Telecommunications

    Electronic Components And Supplies

    Safety Equipment and Supplies

    Tools and General Machinery

    Manufacturing Components and Supplies

    Distribution and Conditioning Systems and Equipment and Components

    Material Handling and Conditioning and Storage Machinery and their Accessories and Supplies

    Electrical Systems and Lighting and Components and Accessories and Supplies

    Laboratory and Measuring and Observing and Testing Equipment

    Industrial Manufacturing and Processing Machinery and Accessories

    Miscellaneous

Showing 1453-1464 of 12,986 results

Mersen C213994 - The NH system is classified among plug-in fuse systems and is composed of: • fuse-base, (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional. NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1×3 times nominal current for up to 10 hours. The fuse link operates at 1×5 times nominal transformer current within 2 hours. 500 Volts 1250 amps gG NH4 series.
Mersen · Ferraz Shawmut

C213994

4086500032204


The NH system is classified among plug-in fuse systems and is composed of: • fuse-base, (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional. NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1×3 times nominal current for up to 10 hours. The fuse link operates at 1×5 times nominal transformer current within 2 hours. 500 Volts 1250 amps gG NH4 series.

Contact for Pricing

Mersen S216055 - The NH system is classified among plug-in fuse systems and is composed of: • fuse-base, (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional. NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1×3 times nominal current for up to 10 hours. The fuse link operates at 1×5 times nominal transformer current within 2 hours. 400 Volts 400 kVA gTR NH4a series.
Mersen · Ferraz Shawmut

S216055

4086500032617


The NH system is classified among plug-in fuse systems and is composed of: • fuse-base, (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional. NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1×3 times nominal current for up to 10 hours. The fuse link operates at 1×5 times nominal transformer current within 2 hours. 400 Volts 400 kVA gTR NH4a series.

Contact for Pricing

Mersen P206438 - The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 6 amps D01 Gauge Ring .
Mersen · Ferraz Shawmut

P206438

4086500010547


The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 6 amps D01 Gauge Ring .

Contact for Pricing

Minimum Qty: 50

Multiplier: 50

*Contact for lower quantities*

Mersen M213014 - The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 10 amps D01 Gauge Ring .
Mersen · Ferraz Shawmut

M213014

4086500010592


The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 10 amps D01 Gauge Ring .

Contact for Pricing

Minimum Qty: 50

Multiplier: 50

*Contact for lower quantities*

Mersen P214028 - The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. D01 to D02
Mersen · Ferraz Shawmut

P214028

4086500011223


The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. D01 to D02

Contact for Pricing

Minimum Qty: 25

Multiplier: 25

*Contact for lower quantities*

Mersen Y213001 - The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 690 Volts 1250 amps NH4 1 pole screw lug fuse base .
Mersen · Ferraz Shawmut

Y213001

4086500033911


The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 690 Volts 1250 amps NH4 1 pole screw lug fuse base .

Contact for Pricing

Mersen Y213507 - The NH system is classified among plug-in fuse systems and is composed of: • fuse-base, (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional. NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1×3 times nominal current for up to 10 hours. The fuse link operates at 1×5 times nominal transformer current within 2 hours. 400 Volts 125 kVA gTR NH4a series.
Mersen · Ferraz Shawmut

Y213507

4086500061624


The NH system is classified among plug-in fuse systems and is composed of: • fuse-base, (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional. NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1×3 times nominal current for up to 10 hours. The fuse link operates at 1×5 times nominal transformer current within 2 hours. 400 Volts 125 kVA gTR NH4a series.

Contact for Pricing

Mersen H211607 - DIN D0 Fuse-link Neozed aM Size D02 440VAC 20A Color code Blue Packaging quantity 10
Mersen

H211607

D02AM44V20


DIN D0 Fuse-link Neozed aM Size D02 440VAC 20A Color code Blue Packaging quantity 10

Contact for Pricing

Minimum Qty: 10

Multiplier: 10

*Contact for lower quantities*

Mersen F212640 - DIN D0 Fuse-link Neozed aM Size D02 440VAC 25A Color code Yellow Packaging quantity 10
Mersen

F212640

D02AM44V25


DIN D0 Fuse-link Neozed aM Size D02 440VAC 25A Color code Yellow Packaging quantity 10

Contact for Pricing

Minimum Qty: 10

Multiplier: 10

*Contact for lower quantities*

Mersen P212464 - DIN NH Standard fuse-link gG Size NH000 500VAC 250VDC 6A isolated tags Double indicator Body width 21mm
Mersen

P212464

NH000GG50V6-1


DIN NH Standard fuse-link gG Size NH000 500VAC 250VDC 6A isolated tags Double indicator Body width 21mm

Contact for Pricing

Minimum Qty: 9

Multiplier: 9

*Contact for lower quantities*

Mersen V215091 - The D fuse-system is the first generation of screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D fuse range comprises the sizes NDZ, DII, DIII, DIV, DV. The range of applications for D fuse-links is the protection of cables and power lines. They limit and cut-off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 500 Volts 63 amps DIII 3 pole fuse base for busbars with cover .
Mersen · Ferraz Shawmut

V215091

4086500054176


The D fuse-system is the first generation of screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D fuse range comprises the sizes NDZ, DII, DIII, DIV, DV. The range of applications for D fuse-links is the protection of cables and power lines. They limit and cut-off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 500 Volts 63 amps DIII 3 pole fuse base for busbars with cover .

Contact for Pricing

Minimum Qty: 8

Multiplier: 8

*Contact for lower quantities*

Mersen N205770 - DIN NH Standard fuse-link gG Size NH000 500VAC 250VDC 4A isolated tags Double indicator Body width 21mm
Mersen

N205770

NH000GG50V4-1


DIN NH Standard fuse-link gG Size NH000 500VAC 250VDC 4A isolated tags Double indicator Body width 21mm

Contact for Pricing

Minimum Qty: 9

Multiplier: 9

*Contact for lower quantities*

Showing 1453-1464 of 12,986 results