Accessories

    Office Equipment and Accessories and Supplies

    Drives, Servos, and Motors

    Power Generation and Distribution Machinery and Accessories

    Structures, Building, and Construction

    Enclosures, Fans, and Environmental Controls

    Information Technology Broadcasting and Telecommunications

    Electronic Components And Supplies

    Safety Equipment and Supplies

    Tools and General Machinery

    Manufacturing Components and Supplies

    Distribution and Conditioning Systems and Equipment and Components

    Material Handling and Conditioning and Storage Machinery and their Accessories and Supplies

    Electrical Systems and Lighting and Components and Accessories and Supplies

    Laboratory and Measuring and Observing and Testing Equipment

    Industrial Manufacturing and Processing Machinery and Accessories

    Miscellaneous

Showing 1081-1092 of 10,147 results

Littelfuse 109002 - FUSE CLIP 09002. Rivet/Eyelet Mount Fuse Clips for 13/16” Dia. Fuses.
Littelfuse · 109 Series

109002

01090002Z


FUSE CLIP 09002. Rivet/Eyelet Mount Fuse Clips for 13/16” Dia. Fuses.

Contact for Pricing

Littelfuse T2000.0020 - Reverse Power Relay. 400/450V L-L 5A. Protects the generator from being run as a motor. The Reverse Power Relay T2000 will protect the generator from being run as an electric motor. The T2000 will protect the prime mover of the generator against physical damage, but will also protect the parallel running generators from overload caused by the inversed load shift in a reverse power situation. T2000 reverse power relay function: The T2000 measures the current through an external 5A CT attached on phase L1. The phase angle (phi) is determined from the voltage measurement across L1 and L2. The T2000 calculates the active current as I x cos phi. If the active current becomes negative and exceeds the preset level (2 – 20 percent), the pick-up LED will activate and the trip delay timer (2 – 20 seconds) will also activate. The built-in trip relay will energize after the delay has passed, provided that the preset trip level was continuously exceeded during the time of the delay.
Littelfuse · Relay Series

T2000.0020


Reverse Power Relay. 400/450V L-L 5A. Protects the generator from being run as a motor. The Reverse Power Relay T2000 will protect the generator from being run as an electric motor. The T2000 will protect the prime mover of the generator against physical damage, but will also protect the parallel running generators from overload caused by the inversed load shift in a reverse power situation. T2000 reverse power relay function: The T2000 measures the current through an external 5A CT attached on phase L1. The phase angle (phi) is determined from the voltage measurement across L1 and L2. The T2000 calculates the active current as I x cos phi. If the active current becomes negative and exceeds the preset level (2 – 20 percent), the pick-up LED will activate and the trip delay timer (2 – 20 seconds) will also activate. The built-in trip relay will energize after the delay has passed, provided that the preset trip level was continuously exceeded during the time of the delay.

Contact for Pricing

Littelfuse MPS-TERM-04 - TERMINAL BLOCK SET MPS-CTU-04. Terminal Block Set MPS-CTU-04.
Littelfuse · MPS Series

MPS-TERM-04


TERMINAL BLOCK SET MPS-CTU-04. Terminal Block Set MPS-CTU-04.

Contact for Pricing

Littelfuse LFT60060FBC - Littelfuse fuseblock covers protect personnel from accidentally coming into contact with energized parts. Covers are for use with various UL class fuseblocks. Please, review the ordering information for available covers.
Littelfuse · LFT Series

LFT60060FBC

LFT60060FBC


Littelfuse fuseblock covers protect personnel from accidentally coming into contact with energized parts. Covers are for use with various UL class fuseblocks. Please, review the ordering information for available covers.

Contact for Pricing

Littelfuse H3455RF2 - ACS INTL SHOCKSAFE 5X20MM FUSEHLDR RF2. International Shock-Safe Panel Mount Fuseholder for 5x20mm Fuses.
Littelfuse · Shock-Safe

H3455RF2


ACS INTL SHOCKSAFE 5X20MM FUSEHLDR RF2. International Shock-Safe Panel Mount Fuseholder for 5x20mm Fuses.

Contact for Pricing

Minimum Qty: 100

Multiplier: 100

*Contact for lower quantities*

Littelfuse MPU-32-01-01 - The MPU-32-01-01 is a motor protection unit with a supply voltage between 65–265 V ac and 80–275 V dc. This unit provides current and temperature-based protection with communication via RS/TIA-232-RS/TIA-485.
Littelfuse · MPU 32 Series

MPU-32-01-01

MPU-32-01-01


The MPU-32-01-01 is a motor protection unit with a supply voltage between 65–265 V ac and 80–275 V dc. This unit provides current and temperature-based protection with communication via RS/TIA-232-RS/TIA-485.

Contact for Pricing

Littelfuse MPU-32-02-00 - The MPU-32-02-00 is a motor protection unit with a supply voltage between 65–265 V ac and 80–275 V dc. This unit provides current and temperature-based protection with communication via RS/TIA-232 - DeviceNet.
Littelfuse · MPU 32 Series

MPU-32-02-00

MPU-32-02-00


The MPU-32-02-00 is a motor protection unit with a supply voltage between 65–265 V ac and 80–275 V dc. This unit provides current and temperature-based protection with communication via RS/TIA-232 - DeviceNet.

Contact for Pricing

Littelfuse LKEY001 - Sturdy steel cabinet holds spare fuses. Cabinet can be locked to prevent unauthorized access and is weather stripped to reduce the accumulation of dust, dirt and moisture. Convenient inventory card located inside door. Measures 30” H x 24” D. Keyhole mounting mounting holes 16” on center for easy installation.
Littelfuse · LSFC Series

LKEY001

LKEY0001Z


Sturdy steel cabinet holds spare fuses. Cabinet can be locked to prevent unauthorized access and is weather stripped to reduce the accumulation of dust, dirt and moisture. Convenient inventory card located inside door. Measures 30” H x 24” D. Keyhole mounting mounting holes 16” on center for easy installation.

Contact for Pricing

Littelfuse LFD5552-3 - POWR-BLOKS power distribution blocks offer a safe, convenient way of splicing cables, providing a fixed junction tap-off point or splitting primary power into secondary circuits. LX2XXX-DIN series offers integral DIN-Rail mount and an optional hinged safety cover.
Littelfuse · POWR-BLOKS

LFD5552-3

LFD55523Z


POWR-BLOKS power distribution blocks offer a safe, convenient way of splicing cables, providing a fixed junction tap-off point or splitting primary power into secondary circuits. LX2XXX-DIN series offers integral DIN-Rail mount and an optional hinged safety cover.

Contact for Pricing

Littelfuse SE-330-03-10 - NGR MONITOR ETHERNET CE. The SE-330 is an advanced ground-fault and neutral-grounding resistor monitoring relay. It measures neutral current, neutral-to ground voltage, and neutral-to-ground resistance. It provides continuous monitoring of the neutral-to-ground path to verify that the neutral-grounding resistor (NGR) is intact. This is of utmost importance—an open NGR renders current-sensing ground-fault protection inoperative and could result in a false belief that the system is functioning properly. The SE-330 can be used with low- and medium-voltage transformers and generators with low- or high-resistance grounding used in processing, manufacturing, chemical, pulp and paper, petroleum,and water-treatment facilities. For high-voltage applications, use the SE-330HV. For applications that require conformance to Australian standard AS/NZS 2081.3:2002, see the SE-330AU. The SE-330 New Revision provides these additional features: 100 trip records with date and time stamp. A mini-USB interface to view measured values, configure settings and check event records using SE-MON330 v3.2 or later. An on-board microSD card (included) can be used for long term data logging and firmware upgrades. Ground-fault trip level is adjustable from 2 to 100percent in 10 discrete settings, and in 1percent increments when using the MEM setting and SE-MON330 v3.2 or later. Dual Ethernet ports are optionally available with support for fiber and RJ45 interfaces. IEC 61850 protocol is optionally available. COMPUTER TO RELAY CONNECTION: Connect the SE-330 to the network using astandard Ethernet patch cable. Use of a crossover cable to connect the SE-330 directly to the computer running IP-Config is not recommended. A typical router will assign an IP address to all connected computers that are using DHCP. The SE-330 does not support the use of DHCP. If the SE-330 is being set-up for first time, it is recommended to only have one SE-330 connected to the network to prevent communication errors.
Littelfuse · SE 330 Series

SE-330-03-10


NGR MONITOR ETHERNET CE. The SE-330 is an advanced ground-fault and neutral-grounding resistor monitoring relay. It measures neutral current, neutral-to ground voltage, and neutral-to-ground resistance. It provides continuous monitoring of the neutral-to-ground path to verify that the neutral-grounding resistor (NGR) is intact. This is of utmost importance—an open NGR renders current-sensing ground-fault protection inoperative and could result in a false belief that the system is functioning properly. The SE-330 can be used with low- and medium-voltage transformers and generators with low- or high-resistance grounding used in processing, manufacturing, chemical, pulp and paper, petroleum,and water-treatment facilities. For high-voltage applications, use the SE-330HV. For applications that require conformance to Australian standard AS/NZS 2081.3:2002, see the SE-330AU. The SE-330 New Revision provides these additional features: 100 trip records with date and time stamp. A mini-USB interface to view measured values, configure settings and check event records using SE-MON330 v3.2 or later. An on-board microSD card (included) can be used for long term data logging and firmware upgrades. Ground-fault trip level is adjustable from 2 to 100percent in 10 discrete settings, and in 1percent increments when using the MEM setting and SE-MON330 v3.2 or later. Dual Ethernet ports are optionally available with support for fiber and RJ45 interfaces. IEC 61850 protocol is optionally available. COMPUTER TO RELAY CONNECTION: Connect the SE-330 to the network using astandard Ethernet patch cable. Use of a crossover cable to connect the SE-330 directly to the computer running IP-Config is not recommended. A typical router will assign an IP address to all connected computers that are using DHCP. The SE-330 does not support the use of DHCP. If the SE-330 is being set-up for first time, it is recommended to only have one SE-330 connected to the network to prevent communication errors.

Contact for Pricing

Littelfuse SE-330-02-10 - NGR MONITOR PROFIBUS CE. The SE-330 is an advanced ground-fault and neutral-grounding resistor monitoring relay. It measures neutral current, neutral-to ground voltage, and neutral-to-ground resistance. It provides continuous monitoring of the neutral-to-ground path to verify that the neutral-grounding resistor (NGR) is intact. This is of utmost importance—an open NGR renders current-sensing ground-fault protection inoperative and could result in a false belief that the system is functioning properly. The SE-330 can be used with low- and medium-voltage transformers and generators with low- or high-resistance grounding used in processing, manufacturing, chemical, pulp and paper, petroleum,and water-treatment facilities. For high-voltage applications, use the SE-330HV. For applications that require conformance to Australian standard AS/NZS 2081.3:2002, see the SE-330AU. The SE-330 New Revision provides these additional features: 100 trip records with date and time stamp. A mini-USB interface to view measured values, configure settings and check event records using SE-MON330 v3.2 or later. An on-board microSD card (included) can be used for long term data logging and firmware upgrades. Ground-fault trip level is adjustable from 2 to 100percent in 10 discrete settings, and in 1percent increments when using the MEM setting and SE-MON330 v3.2 or later. Dual Ethernet ports are optionally available with support for fiber and RJ45 interfaces. IEC 61850 protocol is optionally available. COMPUTER TO RELAY CONNECTION: Connect the SE-330 to the network using astandard Ethernet patch cable. Use of a crossover cable to connect the SE-330 directly to the computer running IP-Config is not recommended. A typical router will assign an IP address to all connected computers that are using DHCP. The SE-330 does not support the use of DHCP. If the SE-330 is being set-up for first time, it is recommended to only have one SE-330 connected to the network to prevent communication errors.
Littelfuse · SE 330 Series

SE-330-02-10


NGR MONITOR PROFIBUS CE. The SE-330 is an advanced ground-fault and neutral-grounding resistor monitoring relay. It measures neutral current, neutral-to ground voltage, and neutral-to-ground resistance. It provides continuous monitoring of the neutral-to-ground path to verify that the neutral-grounding resistor (NGR) is intact. This is of utmost importance—an open NGR renders current-sensing ground-fault protection inoperative and could result in a false belief that the system is functioning properly. The SE-330 can be used with low- and medium-voltage transformers and generators with low- or high-resistance grounding used in processing, manufacturing, chemical, pulp and paper, petroleum,and water-treatment facilities. For high-voltage applications, use the SE-330HV. For applications that require conformance to Australian standard AS/NZS 2081.3:2002, see the SE-330AU. The SE-330 New Revision provides these additional features: 100 trip records with date and time stamp. A mini-USB interface to view measured values, configure settings and check event records using SE-MON330 v3.2 or later. An on-board microSD card (included) can be used for long term data logging and firmware upgrades. Ground-fault trip level is adjustable from 2 to 100percent in 10 discrete settings, and in 1percent increments when using the MEM setting and SE-MON330 v3.2 or later. Dual Ethernet ports are optionally available with support for fiber and RJ45 interfaces. IEC 61850 protocol is optionally available. COMPUTER TO RELAY CONNECTION: Connect the SE-330 to the network using astandard Ethernet patch cable. Use of a crossover cable to connect the SE-330 directly to the computer running IP-Config is not recommended. A typical router will assign an IP address to all connected computers that are using DHCP. The SE-330 does not support the use of DHCP. If the SE-330 is being set-up for first time, it is recommended to only have one SE-330 connected to the network to prevent communication errors.

Contact for Pricing

Littelfuse PMA-1 - Used for rough cut-outs and when replacing the GE Multilin P4A.
Littelfuse · PMA Series

PMA-1

PMA-1


Used for rough cut-outs and when replacing the GE Multilin P4A.

Contact for Pricing

Showing 1081-1092 of 10,147 results