Accessories

    Drives, Servos, and Motors

    Enclosures, Fans, and Environmental Controls

    Laboratory and Measuring and Observing and Testing Equipment

    Industrial Manufacturing and Processing Machinery and Accessories

    Safety Equipment and Supplies

    Miscellaneous

    Distribution and Conditioning Systems and Equipment and Components

    Information Technology Broadcasting and Telecommunications

    Tools and General Machinery

    Manufacturing Components and Supplies

    Structures, Building, and Construction

    Power Generation and Distribution Machinery and Accessories

    Electronic Components And Supplies

    Material Handling and Conditioning and Storage Machinery and their Accessories and Supplies

    Office Equipment and Accessories and Supplies

    Electrical Systems and Lighting and Components and Accessories and Supplies

Showing 373-384 of 10,142 results

Littelfuse LFT60030FBC - Littelfuse fuseblock covers protect personnel from accidentally coming into contact with energized parts. Covers are for use with various UL class fuseblocks. Please, review the ordering information for available covers.
Littelfuse · LFT Series

LFT60030FBC

LFT60030FBC


Littelfuse fuseblock covers protect personnel from accidentally coming into contact with energized parts. Covers are for use with various UL class fuseblocks. Please, review the ordering information for available covers.

Contact for Pricing

Littelfuse SE-330-23-10 - NGR MONITOR 48-VDC ETHERNET CE. The SE-330 is an advanced ground-fault and neutral-grounding resistor monitoring relay. It measures neutral current, neutral-to ground voltage, and neutral-to-ground resistance. It provides continuous monitoring of the neutral-to-ground path to verify that the neutral-grounding resistor (NGR) is intact. This is of utmost importance—an open NGR renders current-sensing ground-fault protection inoperative and could result in a false belief that the system is functioning properly. The SE-330 can be used with low- and medium-voltage transformers and generators with low- or high-resistance grounding used in processing, manufacturing, chemical, pulp and paper, petroleum,and water-treatment facilities. For high-voltage applications, use the SE-330HV. For applications that require conformance to Australian standard AS/NZS 2081.3:2002, see the SE-330AU. The SE-330 New Revision provides these additional features: 100 trip records with date and time stamp. A mini-USB interface to view measured values, configure settings and check event records using SE-MON330 v3.2 or later. An on-board microSD card (included) can be used for long term data logging and firmware upgrades. Ground-fault trip level is adjustable from 2 to 100percent in 10 discrete settings, and in 1percent increments when using the MEM setting and SE-MON330 v3.2 or later. Dual Ethernet ports are optionally available with support for fiber and RJ45 interfaces. IEC 61850 protocol is optionally available. COMPUTER TO RELAY CONNECTION: Connect the SE-330 to the network using astandard Ethernet patch cable. Use of a crossover cable to connect the SE-330 directly to the computer running IP-Config is not recommended. A typical router will assign an IP address to all connected computers that are using DHCP. The SE-330 does not support the use of DHCP. If the SE-330 is being set-up for first time, it is recommended to only have one SE-330 connected to the network to prevent communication errors.
Littelfuse · SE 330 Series

SE-330-23-10


NGR MONITOR 48-VDC ETHERNET CE. The SE-330 is an advanced ground-fault and neutral-grounding resistor monitoring relay. It measures neutral current, neutral-to ground voltage, and neutral-to-ground resistance. It provides continuous monitoring of the neutral-to-ground path to verify that the neutral-grounding resistor (NGR) is intact. This is of utmost importance—an open NGR renders current-sensing ground-fault protection inoperative and could result in a false belief that the system is functioning properly. The SE-330 can be used with low- and medium-voltage transformers and generators with low- or high-resistance grounding used in processing, manufacturing, chemical, pulp and paper, petroleum,and water-treatment facilities. For high-voltage applications, use the SE-330HV. For applications that require conformance to Australian standard AS/NZS 2081.3:2002, see the SE-330AU. The SE-330 New Revision provides these additional features: 100 trip records with date and time stamp. A mini-USB interface to view measured values, configure settings and check event records using SE-MON330 v3.2 or later. An on-board microSD card (included) can be used for long term data logging and firmware upgrades. Ground-fault trip level is adjustable from 2 to 100percent in 10 discrete settings, and in 1percent increments when using the MEM setting and SE-MON330 v3.2 or later. Dual Ethernet ports are optionally available with support for fiber and RJ45 interfaces. IEC 61850 protocol is optionally available. COMPUTER TO RELAY CONNECTION: Connect the SE-330 to the network using astandard Ethernet patch cable. Use of a crossover cable to connect the SE-330 directly to the computer running IP-Config is not recommended. A typical router will assign an IP address to all connected computers that are using DHCP. The SE-330 does not support the use of DHCP. If the SE-330 is being set-up for first time, it is recommended to only have one SE-330 connected to the network to prevent communication errors.

Contact for Pricing

Littelfuse M8100.0170 - Synchroscope. The M8100 Synchroscope provides illuminated indication of the frequency and phase deviation between voltages on two separate AC systems (e.g. a generator and a busbar). The M8100 will also indicate whether or not the two systems are live. A moving light dot indicates the frequency deviation. The magnitude of the frequency deviation is indicated by the speed and direction of the movement. Clockwise movement indicates that the frequency is too high on the incoming system. Counter clockwise movement indicates that the frequency is too low. A steady light dot at 6 o’clock position indicates zero frequency deviation and 180 degrees phase deviation. Exact synchronization. frequency and phase accordance is achieved when the light dot is steady at the 12 o’clock position (when the green LEDs ignite). The M8100 scale is made up from 38 bright red LEDs. The resolution provided by the 38 LEDs is almost as fine as a pointer synchroscope, however the LED based design is far better at withstanding environmental influence from vibration, temperature and humidity.
Littelfuse · M8100 Series

M8100.0170


Synchroscope. The M8100 Synchroscope provides illuminated indication of the frequency and phase deviation between voltages on two separate AC systems (e.g. a generator and a busbar). The M8100 will also indicate whether or not the two systems are live. A moving light dot indicates the frequency deviation. The magnitude of the frequency deviation is indicated by the speed and direction of the movement. Clockwise movement indicates that the frequency is too high on the incoming system. Counter clockwise movement indicates that the frequency is too low. A steady light dot at 6 o’clock position indicates zero frequency deviation and 180 degrees phase deviation. Exact synchronization. frequency and phase accordance is achieved when the light dot is steady at the 12 o’clock position (when the green LEDs ignite). The M8100 scale is made up from 38 bright red LEDs. The resolution provided by the 38 LEDs is almost as fine as a pointer synchroscope, however the LED based design is far better at withstanding environmental influence from vibration, temperature and humidity.

Contact for Pricing

Littelfuse SE-330-03-01 - SE-330-03-01 is an advanced ground-fault and neutral-grounding resistor monitor with a supply voltage ac of 65–265 and a supply voltage dc of 85–275. Network communications is offered via USB; Ethernet (Dual RJ45).
Littelfuse · SE 330 Series

SE-330-03-01

SE-330-03-01


SE-330-03-01 is an advanced ground-fault and neutral-grounding resistor monitor with a supply voltage ac of 65–265 and a supply voltage dc of 85–275. Network communications is offered via USB; Ethernet (Dual RJ45).

Contact for Pricing

Littelfuse SE-330-20-00 - SE-330-20-00 is an advanced ground-fault and neutral-grounding resistor monitor with a supply voltage ac of 28–52 and a supply voltage dc of 36–72. Network communications is offered via USB.
Littelfuse · SE 330 Series

SE-330-20-00

SE-330-20-00


SE-330-20-00 is an advanced ground-fault and neutral-grounding resistor monitor with a supply voltage ac of 28–52 and a supply voltage dc of 36–72. Network communications is offered via USB.

Contact for Pricing

Littelfuse SE-325EST - SE-325EST is a neutral-grounding resistor monitor with a supply voltage of 240 ac and a ground-fault trip level of 0.5–4.0 A.
Littelfuse · SE 325 Series

SE-325EST

SE-325EST


SE-325EST is a neutral-grounding resistor monitor with a supply voltage of 240 ac and a ground-fault trip level of 0.5–4.0 A.

Contact for Pricing

Littelfuse SE-325N - SE-325N is a neutral-grounding resistor monitor with a supply voltage of 120 ac and a ground-fault trip level of 0.5–4.0 A.
Littelfuse · SE 325 Series

SE-325N

SE-325N


SE-325N is a neutral-grounding resistor monitor with a supply voltage of 120 ac and a ground-fault trip level of 0.5–4.0 A.

Contact for Pricing

Littelfuse LEYYYCS - ACS CLASSCC INLINE HOLDER 30A 2 POLE
Littelfuse · LEY Series

LEYYYCS


ACS CLASSCC INLINE HOLDER 30A 2 POLE

Contact for Pricing

Littelfuse LTFD101-1000 - 80VDC 125A TLS DISCONNECT W/ BULLET
Littelfuse · LTFD Series

LTFD101-1000


80VDC 125A TLS DISCONNECT W/ BULLET

Contact for Pricing

Littelfuse SE-330-04-00 - NGR MON.,UNIV., ETHERNET SC FIBER & RJ45
Littelfuse · SE 330 Series

SE-330-04-00


NGR MON.,UNIV., ETHERNET SC FIBER & RJ45

Contact for Pricing

Littelfuse L60QS40A-6 - HSF 10X38 CYL PCB 600V AC/DC 40A
Littelfuse · L60QS Series

L60QS40A-6


HSF 10X38 CYL PCB 600V AC/DC 40A

Contact for Pricing

Minimum Qty: 10

Multiplier: 10

*Contact for lower quantities*

Littelfuse SE-330AU-00-01 - SE-330AU-00-01 is an advanced neutral-earthing resistor monitor with a supply voltage ac of 65–265 and a supply voltage dc of 85–275. Network communications is offered via USB.
Littelfuse · SE 330 Series

SE-330AU-00-01

SE-330AU-00-01


SE-330AU-00-01 is an advanced neutral-earthing resistor monitor with a supply voltage ac of 65–265 and a supply voltage dc of 85–275. Network communications is offered via USB.

Contact for Pricing

Showing 373-384 of 10,142 results