Littelfuse · Relay Series
T2000.0010
Reverse Power Relay. 230V L-N 5A. Protects the generator from being run as a motor. The Reverse Power Relay T2000 will protect the generator from being run as an electric motor. The T2000 will protect the prime mover of the generator against physical damage, but will also protect the parallel running generators from overload caused by the inversed load shift in a reverse power situation. T2000 reverse power relay function: The T2000 measures the current through an external 5A CT attached on phase L1. The phase angle (phi) is determined from the voltage measurement across L1 and L2. The T2000 calculates the active current as I x cos phi. If the active current becomes negative and exceeds the preset level (2 – 20 percent), the pick-up LED will activate and the trip delay timer (2 – 20 seconds) will also activate. The built-in trip relay will energize after the delay has passed, provided that the preset trip level was continuously exceeded during the time of the delay.
Contact for Pricing

3AG MTG 2 POLE NEMA STYLE 3/16. A low profile fuse block featuring individual barriers which reinforce the fuse clips while providing greater protection against clip damage and electrical shock. The unique design permits self-alignment of clips to fuse cap. This, plus a one-piece clip/terminal assures low contact resistance. Higher current ratings have been attained using spring brass clips. With the exception of the two-pole unit, multiple pole units may be broken apart to obtain desired number of poles.
Contact for Pricing

POWR-BLOKS power distribution blocks offer a safe, convenient way of splicing cables, providing a fixed junction tap-off point or splitting primary power into secondary circuits. LX2XXX-DIN series offers integral DIN-Rail mount and an optional hinged safety cover.
Contact for Pricing

The SPFJ series is the smallest 1000 V dc 70-450 A dc Full Range fuse available in the market. The SPFJ series is manufactured in Class J case sizes are suitable for photovoltaic, DC cable protection, EV off-board charging and other dc applications. that allows for both fuse holder and busbar mounting config.
Contact for Pricing

The SPFJ series is the smallest 1000 V dc 70-450 A dc Full Range fuse available in the market. The SPFJ series is manufactured in Class J case sizes are suitable for photovoltaic, DC cable protection, EV off-board charging and other dc applications. that allows for both fuse holder and busbar mounting config.
Contact for Pricing

The SPFJ series is the smallest 1000 V dc 70-450 A dc Full Range fuse available in the market. The SPFJ series is manufactured in Class J case sizes are suitable for photovoltaic, DC cable protection, EV off-board charging and other dc applications. that allows for both fuse holder and busbar mounting config.
Contact for Pricing

The SPFJ series is the smallest 1000 V dc 70-450 A dc Full Range fuse available in the market. The SPFJ series is manufactured in Class J case sizes are suitable for photovoltaic, DC cable protection, EV off-board charging and other dc applications. that allows for both fuse holder and busbar mounting config.
Contact for Pricing

Littelfuse fuseblock covers protect personnel from accidentally coming into contact with energized parts. Covers are for use with various UL class fuseblocks. Please, review the ordering information for available covers.
Contact for Pricing

Littelfuse · SE 330 Series
SE-330-01-10
NGR MONITOR DEVICENET CE. The SE-330 is an advanced ground-fault and neutral-grounding resistor monitoring relay. It measures neutral current, neutral-to ground voltage, and neutral-to-ground resistance. It provides continuous monitoring of the neutral-to-ground path to verify that the neutral-grounding resistor (NGR) is intact. This is of utmost importance—an open NGR renders current-sensing ground-fault protection inoperative and could result in a false belief that the system is functioning properly. The SE-330 can be used with low- and medium-voltage transformers and generators with low- or high-resistance grounding used in processing, manufacturing, chemical, pulp and paper, petroleum,and water-treatment facilities. For high-voltage applications, use the SE-330HV. For applications that require conformance to Australian standard AS/NZS 2081.3:2002, see the SE-330AU. The SE-330 New Revision provides these additional features: 100 trip records with date and time stamp. A mini-USB interface to view measured values, configure settings and check event records using SE-MON330 v3.2 or later. An on-board microSD card (included) can be used for long term data logging and firmware upgrades. Ground-fault trip level is adjustable from 2 to 100percent in 10 discrete settings, and in 1percent increments when using the MEM setting and SE-MON330 v3.2 or later. Dual Ethernet ports are optionally available with support for fiber and RJ45 interfaces. IEC 61850 protocol is optionally available. COMPUTER TO RELAY CONNECTION: Connect the SE-330 to the network using astandard Ethernet patch cable. Use of a crossover cable to connect the SE-330 directly to the computer running IP-Config is not recommended. A typical router will assign an IP address to all connected computers that are using DHCP. The SE-330 does not support the use of DHCP. If the SE-330 is being set-up for first time, it is recommended to only have one SE-330 connected to the network to prevent communication errors.
Contact for Pricing

Littelfuse · SE 330 Series
SE-330-01-11
NGR MONITOR DEVICENET NC-K4 CE. The SE-330 is an advanced ground-fault and neutral-grounding resistor monitoring relay. It measures neutral current, neutral-to ground voltage, and neutral-to-ground resistance. It provides continuous monitoring of the neutral-to-ground path to verify that the neutral-grounding resistor (NGR) is intact. This is of utmost importance—an open NGR renders current-sensing ground-fault protection inoperative and could result in a false belief that the system is functioning properly. The SE-330 can be used with low- and medium-voltage transformers and generators with low- or high-resistance grounding used in processing, manufacturing, chemical, pulp and paper, petroleum,and water-treatment facilities. For high-voltage applications, use the SE-330HV. For applications that require conformance to Australian standard AS/NZS 2081.3:2002, see the SE-330AU. The SE-330 New Revision provides these additional features: 100 trip records with date and time stamp. A mini-USB interface to view measured values, configure settings and check event records using SE-MON330 v3.2 or later. An on-board microSD card (included) can be used for long term data logging and firmware upgrades. Ground-fault trip level is adjustable from 2 to 100percent in 10 discrete settings, and in 1percent increments when using the MEM setting and SE-MON330 v3.2 or later. Dual Ethernet ports are optionally available with support for fiber and RJ45 interfaces. IEC 61850 protocol is optionally available. COMPUTER TO RELAY CONNECTION: Connect the SE-330 to the network using astandard Ethernet patch cable. Use of a crossover cable to connect the SE-330 directly to the computer running IP-Config is not recommended. A typical router will assign an IP address to all connected computers that are using DHCP. The SE-330 does not support the use of DHCP. If the SE-330 is being set-up for first time, it is recommended to only have one SE-330 connected to the network to prevent communication errors.
Contact for Pricing

The SE-100T is a ground-fault-relay test unit designed to test the current pickup level of ground-fault protection. The tester injects current through the window of installed ground-fault current transformers to verify the operation of ground-fault monitors and relays. It is used on substations, motor control centers (MCCs), central distribution panels, switchboards, and test benches to verify relay operation. The SE-100T tests the entire ground-fault circuit including current transformers, wiring, ground-fault relay and the operation of the interrupting device. It is recommended to test every relay and its current interrupting device annually.
Contact for Pricing

The SE-105/SE-107 is a combination ground-wire monitor and ground-fault relay for resistance-grounded systems. It continuously monitors the integrity of the ground conductor to protect portable equipment from hazardous voltages caused by ground faults. The SE-105/SE-107 is an excellent choice for trailing cables 5 kV and under in underground mining applications. For higher voltages or long-cable applications, see the SE-134C/SE-135.
Contact for Pricing