Accessories

    Office Equipment and Accessories and Supplies

    Drives, Servos, and Motors

    Power Generation and Distribution Machinery and Accessories

    Structures, Building, and Construction

    Enclosures, Fans, and Environmental Controls

    Information Technology Broadcasting and Telecommunications

    Electronic Components And Supplies

    Safety Equipment and Supplies

    Tools and General Machinery

    Manufacturing Components and Supplies

    Distribution and Conditioning Systems and Equipment and Components

    Material Handling and Conditioning and Storage Machinery and their Accessories and Supplies

    Electrical Systems and Lighting and Components and Accessories and Supplies

    Laboratory and Measuring and Observing and Testing Equipment

    Industrial Manufacturing and Processing Machinery and Accessories

    Miscellaneous

Showing 2581-2592 of 2,825 results

Danfoss 134G8765 - VLT® AQUA Drive FC 202, 160 kW / 250 HP, Three phase 525-690V, IP20, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, Coated PCB, standard controller, Standard cable entries, 192 A continuous, frame D3h
Danfoss

134G8765

FC-202N160T7E20H2XGCXXXSXXXXAXBXCXXXXDX


VLT® AQUA Drive FC 202, 160 kW / 250 HP, Three phase 525-690V, IP20, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, Coated PCB, standard controller, Standard cable entries, 192 A continuous, frame D3h

Contact for Pricing

Danfoss 134G8273 - VLT® AQUA Drive FC 202, 250 kW / 350 HP, Three phase 525-690V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, Coated PCB, standard controller, Standard cable entries, 290 A continuous, frame D2h
Danfoss

134G8273

FC-202N250T7E21H2XGCXXXSXXXXAXBXCXXXXDX


VLT® AQUA Drive FC 202, 250 kW / 350 HP, Three phase 525-690V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, Coated PCB, standard controller, Standard cable entries, 290 A continuous, frame D2h

Contact for Pricing

Danfoss 134G8773 - VLT® AQUA Drive FC 202, 200 kW / 300 HP, Three phase 525-690V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, Coated PCB, standard controller, Standard cable entries, 242 A continuous, frame D2h
Danfoss

134G8773

FC-202N200T7E54H2XGCXXXSXXXXAXBXCXXXXDX


VLT® AQUA Drive FC 202, 200 kW / 300 HP, Three phase 525-690V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, Coated PCB, standard controller, Standard cable entries, 242 A continuous, frame D2h

Contact for Pricing

Danfoss 134G9349 - VLT® AutomationDrive FC 302, 110 kW / 150 HP, 525-690 V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, Coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 125 HP, 131 A continuous, frame D5h
Danfoss

134G9349

FC-302N110T7E54H2XGC3XXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 302, 110 kW / 150 HP, 525-690 V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, Coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 125 HP, 131 A continuous, frame D5h

Contact for Pricing

Danfoss 134G9354 - VLT® AutomationDrive FC 302, 315 kW / 450 HP, 525-690 V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, Coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 350 HP, 344 A continuous, frame D7h
Danfoss

134G9354

FC-302N315T7E54H2XGC3XXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 302, 315 kW / 450 HP, 525-690 V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, Coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 350 HP, 344 A continuous, frame D7h

Contact for Pricing

Danfoss 134H0041 - VLT® AutomationDrive FC 302, 250 kW / 350 HP, 380-500 V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, Brake chopper included, Graphical local control panel, Coated PCB, standard controller, Standard cable entries, 350 HP, 443 A continuous
Danfoss

134H0041

FC-302N250T5E54H2BGCXXXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 302, 250 kW / 350 HP, 380-500 V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, Brake chopper included, Graphical local control panel, Coated PCB, standard controller, Standard cable entries, 350 HP, 443 A continuous

Contact for Pricing

Danfoss 134H1365 - VLT® AQUA Drive FC 202, 110 kW / 150 HP, Three phase 380-480V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, Coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 190 A continuous, frame D5h
Danfoss

134H1365

FC-202N110T4E21H2XGC3XXSXXXXAXBXCXXXXDX


VLT® AQUA Drive FC 202, 110 kW / 150 HP, Three phase 380-480V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, Coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 190 A continuous, frame D5h

Contact for Pricing

Danfoss 134H0687 - VLT® AQUA Drive FC 202, 132 kW / 200 HP, Three phase 380-480V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, Coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 240 A continuous, frame D5h
Danfoss

134H0687

FC-202N132T4E21H2XGC3XXSXXXXAXBXCXXXXDX


VLT® AQUA Drive FC 202, 132 kW / 200 HP, Three phase 380-480V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, Coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 240 A continuous, frame D5h

Contact for Pricing

Danfoss 134H1119 - VLT® AutomationDrive FC 302, 160 kW / 250 HP, 380-500 V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, Brake chopper included, Graphical local control panel, Coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 250 HP, 302 A continuous, frame D7h
Danfoss

134H1119

FC-302N160T5E21H2BGC3XXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 302, 160 kW / 250 HP, 380-500 V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, Brake chopper included, Graphical local control panel, Coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 250 HP, 302 A continuous, frame D7h

Contact for Pricing

Danfoss 134H0702 - VLT® AQUA Drive FC 202, 0.75 kW / 1.0 HP, Three phase 525-600V, No brake chopper included, Graphical local control panel, No coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 1.7 A continuous, frame A3
Danfoss

134H0702

FC-202PK75T6E21HXXGX3XXSXXXXAXBXCXXXXDX


VLT® AQUA Drive FC 202, 0.75 kW / 1.0 HP, Three phase 525-600V, No brake chopper included, Graphical local control panel, No coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 1.7 A continuous, frame A3

Contact for Pricing

Danfoss 134H1367 - VLT® AQUA Drive FC 202, 250 kW / 350 HP, Three phase 380-480V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, Coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 443 A continuous, frame D7h
Danfoss

134H1367

FC-202N250T4E21H2XGC3XXSXXXXAXBXCXXXXDX


VLT® AQUA Drive FC 202, 250 kW / 350 HP, Three phase 380-480V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, Coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 443 A continuous, frame D7h

Contact for Pricing

Danfoss 134H1387 - VLT® AQUA Drive FC 202, 132 kW / 200 HP, Three phase 380-480V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, Coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 240 A continuous
Danfoss

134H1387

FC-202N132T4E54H2XGC3XXSXXXXAXBXCXXXXDX


VLT® AQUA Drive FC 202, 132 kW / 200 HP, Three phase 380-480V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, Coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 240 A continuous

Contact for Pricing

Showing 2581-2592 of 2,825 results