Accessories

    Office Equipment and Accessories and Supplies

    Drives, Servos, and Motors

    Power Generation and Distribution Machinery and Accessories

    Structures, Building, and Construction

    Enclosures, Fans, and Environmental Controls

    Information Technology Broadcasting and Telecommunications

    Electronic Components And Supplies

    Safety Equipment and Supplies

    Tools and General Machinery

    Manufacturing Components and Supplies

    Distribution and Conditioning Systems and Equipment and Components

    Material Handling and Conditioning and Storage Machinery and their Accessories and Supplies

    Electrical Systems and Lighting and Components and Accessories and Supplies

    Laboratory and Measuring and Observing and Testing Equipment

    Industrial Manufacturing and Processing Machinery and Accessories

    Miscellaneous

Showing 1657-1668 of 2,825 results

Danfoss 131B5915 - VLT® AutomationDrive FC 302, 45 kW / 60 HP, 380-500 V, IP 55/NEMA Type 12, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, Brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 60 HP, 80 A continuous, frame C1
Danfoss

131B5915

FC-302P45KT5E55H2BGXXXXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 302, 45 kW / 60 HP, 380-500 V, IP 55/NEMA Type 12, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, Brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 60 HP, 80 A continuous, frame C1

Contact for Pricing

Danfoss 131B5906 - VLT® AutomationDrive FC 302, 37 kW / 50 HP, 380-500 V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 50 HP, 65 A continuous, frame C1
Danfoss

131B5906

FC-302P37KT5E21H2XGXXXXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 302, 37 kW / 50 HP, 380-500 V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 50 HP, 65 A continuous, frame C1

Contact for Pricing

Danfoss 131B6029 - VLT® AutomationDrive FC 302, 22 kW / 30 HP, 200-240 V, IP 55/NEMA Type 12, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 30 HP, 88 A continuous, frame C1
Danfoss

131B6029

FC-302P22KT2E55H2XGXXXXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 302, 22 kW / 30 HP, 200-240 V, IP 55/NEMA Type 12, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 30 HP, 88 A continuous, frame C1

Contact for Pricing

Danfoss 131B6032 - VLT® AutomationDrive FC 302, 55 kW / 75 HP, 380-500 V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 75 HP, 105 A continuous, frame C2
Danfoss

131B6032

FC-302P55KT5E21H2XGXXXXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 302, 55 kW / 75 HP, 380-500 V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 75 HP, 105 A continuous, frame C2

Contact for Pricing

Danfoss 131B6031 - VLT® AutomationDrive FC 302, 22 kW / 30 HP, 200-240 V, IP 55/NEMA Type 12, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, Brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 30 HP, 88 A continuous, frame C1
Danfoss

131B6031

FC-302P22KT2E55H2BGXXXXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 302, 22 kW / 30 HP, 200-240 V, IP 55/NEMA Type 12, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, Brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 30 HP, 88 A continuous, frame C1

Contact for Pricing

Danfoss 131B6036 - VLT® AutomationDrive FC 302, 55 kW / 75 HP, 380-500 V, IP 55/NEMA Type 12, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, Brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 75 HP, 105 A continuous, frame C2
Danfoss

131B6036

FC-302P55KT5E55H2BGXXXXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 302, 55 kW / 75 HP, 380-500 V, IP 55/NEMA Type 12, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, Brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 75 HP, 105 A continuous, frame C2

Contact for Pricing

Danfoss 131B6039 - VLT® AutomationDrive FC 302, 75 kW / 100 HP, 380-500 V, IP 55/NEMA Type 12, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 100 HP, 130 A continuous, frame C2
Danfoss

131B6039

FC-302P75KT5E55H2XGXXXXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 302, 75 kW / 100 HP, 380-500 V, IP 55/NEMA Type 12, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 100 HP, 130 A continuous, frame C2

Contact for Pricing

Danfoss 131B6047 - VLT® AutomationDrive FC 301, 15 kW / 20 HP, 200-240 V, IP 55/NEMA Type 12, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 20 HP, 59.4 A continuous, frame C1
Danfoss

131B6047

FC-301P15KT2E55H2XGXXXXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 301, 15 kW / 20 HP, 200-240 V, IP 55/NEMA Type 12, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 20 HP, 59.4 A continuous, frame C1

Contact for Pricing

Danfoss 131B6088 - VLT® AutomationDrive FC 301, 30 kW / 40 HP, 380-480 V, IP 55/NEMA Type 12, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 40 HP, 52 A continuous, frame C1
Danfoss

131B6088

FC-301P30KT4E55H2XGXXXXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 301, 30 kW / 40 HP, 380-480 V, IP 55/NEMA Type 12, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 40 HP, 52 A continuous, frame C1

Contact for Pricing

Danfoss 131B6110 - VLT® AutomationDrive FC 301, 55 kW / 75 HP, 380-480 V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 75 HP, 105 A continuous, frame C2
Danfoss

131B6110

FC-301P55KT4E21H2XGXXXXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 301, 55 kW / 75 HP, 380-480 V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 75 HP, 105 A continuous, frame C2

Contact for Pricing

Danfoss 131B6084 - VLT® AutomationDrive FC 301, 30 kW / 40 HP, 380-480 V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 40 HP, 52 A continuous, frame C1
Danfoss

131B6084

FC-301P30KT4E21H2XGXXXXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 301, 30 kW / 40 HP, 380-480 V, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 40 HP, 52 A continuous, frame C1

Contact for Pricing

Danfoss 131B6055 - VLT® AutomationDrive FC 301, 18.5 kW / 25 HP, 200-240 V, IP 55/NEMA Type 12, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 25 HP, 74.8 A continuous, frame C1
Danfoss

131B6055

FC-301P18KT2E55H2XGXXXXSXXXXAXBXCXXXXDX


VLT® AutomationDrive FC 301, 18.5 kW / 25 HP, 200-240 V, IP 55/NEMA Type 12, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 25 HP, 74.8 A continuous, frame C1

Contact for Pricing

Showing 1657-1668 of 2,825 results