Accessories

    Office Equipment and Accessories and Supplies

    Drives, Servos, and Motors

    Power Generation and Distribution Machinery and Accessories

    Structures, Building, and Construction

    Enclosures, Fans, and Environmental Controls

    Information Technology Broadcasting and Telecommunications

    Electronic Components And Supplies

    Safety Equipment and Supplies

    Tools and General Machinery

    Manufacturing Components and Supplies

    Distribution and Conditioning Systems and Equipment and Components

    Material Handling and Conditioning and Storage Machinery and their Accessories and Supplies

    Electrical Systems and Lighting and Components and Accessories and Supplies

    Laboratory and Measuring and Observing and Testing Equipment

    Industrial Manufacturing and Processing Machinery and Accessories

    Miscellaneous

Showing 4573-4584 of 18,040 results

ABB - Electrification TEY240 - The TEY is a one-inch wide per pole, compact, "bolt-on" circuit breaker for use on grounded 480Y/277 Vac systems. The bolt-on mounting base accessory makes the TEY suitable for varied applications as a lug-lug breaker. All TEY circuit breakers feature Quick-make / Quick-break mechanisms, common trip bars, and easy to spot trip indication to ensure safety and reliability. TEY breakers are available in 1, 2, and 3 pole versions and can be ordered with auxiliary contact and shunt trip accessories. CIRCUIT BREAKER TWO POLE
ABB - Electrification · GE · TEY

TEY240


The TEY is a one-inch wide per pole, compact, "bolt-on" circuit breaker for use on grounded 480Y/277 Vac systems. The bolt-on mounting base accessory makes the TEY suitable for varied applications as a lug-lug breaker. All TEY circuit breakers feature Quick-make / Quick-break mechanisms, common trip bars, and easy to spot trip indication to ensure safety and reliability. TEY breakers are available in 1, 2, and 3 pole versions and can be ordered with auxiliary contact and shunt trip accessories. CIRCUIT BREAKER TWO POLE

Contact for Pricing

ABB - Electrification TL42420C - Main lug load centers can be used as a home's main panel or sub panel depending upon your preferences. All ABB load centers are rated up to 60 degree/75 degree centrigrade and is suitable for use with service entrance equipment when installed in accordance with electrical code. The TL42420C features space for 42, 1" breakers, 3 phases, 200 A bus ampere rating, and a combination/flush enclosure.
ABB - Electrification · GE

TL42420C


Main lug load centers can be used as a home's main panel or sub panel depending upon your preferences. All ABB load centers are rated up to 60 degree/75 degree centrigrade and is suitable for use with service entrance equipment when installed in accordance with electrical code. The TL42420C features space for 42, 1" breakers, 3 phases, 200 A bus ampere rating, and a combination/flush enclosure.

Contact for Pricing

ABB - Electrification TM24415C - Main breaker load centers arrive with a main breaker installed for a convenient and swift install. Main breakers allow for the user to stop the flow of electricity in the load center, shutting off all the power in the residence. The TM24415CB features spaces for 24, 1" breakers, a 150A main ampere rating, 3 phases, a bottom feed, and a combination/flush enclosure.
ABB - Electrification · GE

TM24415C


Main breaker load centers arrive with a main breaker installed for a convenient and swift install. Main breakers allow for the user to stop the flow of electricity in the load center, shutting off all the power in the residence. The TM24415CB features spaces for 24, 1" breakers, a 150A main ampere rating, 3 phases, a bottom feed, and a combination/flush enclosure.

Contact for Pricing

ABB - Electrification 9T51B0810 - ABB's Buck-boost transformers are small, single phase, dry type distribution transformers designed and shipped as insulating/isolating transformers. They have a dual voltage primary and a dual voltage secondary. These transformers can be connected for a wide range of voltage combinations. The most common use is to buck (lower) or boost (raise) the supply voltage a small amount, usually 5 to 27%. Buck boost transformers comply with NEC Article 210-9, Exception 1, when field connected as an autotransformer.
ABB - Electrification · GE

9T51B0810


ABB's Buck-boost transformers are small, single phase, dry type distribution transformers designed and shipped as insulating/isolating transformers. They have a dual voltage primary and a dual voltage secondary. These transformers can be connected for a wide range of voltage combinations. The most common use is to buck (lower) or boost (raise) the supply voltage a small amount, usually 5 to 27%. Buck boost transformers comply with NEC Article 210-9, Exception 1, when field connected as an autotransformer.

Contact for Pricing

ABB - Electrification TM42415CB - Main breaker load centers arrive with a main breaker installed for a convenient and swift install. Main breakers allow for the user to stop the flow of electricity in the load center, shutting off all the power in the residence. The TM42415CB features spaces for 42, 1" breakers, a 150A main ampere rating, 3 phases, a bottom feed, and a combination surface/flush enclosure.
ABB - Electrification · GE

TM42415CB


Main breaker load centers arrive with a main breaker installed for a convenient and swift install. Main breakers allow for the user to stop the flow of electricity in the load center, shutting off all the power in the residence. The TM42415CB features spaces for 42, 1" breakers, a 150A main ampere rating, 3 phases, a bottom feed, and a combination surface/flush enclosure.

Contact for Pricing

ABB - Electrification TPL412CT - Main lug load centers can be used as a home's main panel or sub panel depending upon your preferences. All ABB load centers are rated up to 60 degree/75 degree centrigrade and is suitable for use with service entrance equipment when installed in accordance with electrical code. The TPL412CT is made of thermoplastic and features spaces for 4, 1" breakers, a 125A main ampere rating, a factory included ground bar, and a combination surface/flush enclosure.
ABB - Electrification · GE

TPL412CT


Main lug load centers can be used as a home's main panel or sub panel depending upon your preferences. All ABB load centers are rated up to 60 degree/75 degree centrigrade and is suitable for use with service entrance equipment when installed in accordance with electrical code. The TPL412CT is made of thermoplastic and features spaces for 4, 1" breakers, a 125A main ampere rating, a factory included ground bar, and a combination surface/flush enclosure.

Contact for Pricing

ABB - Electrification TL12412R - Main lug load centers can be used as a home's main panel or sub panel depending upon your preferences. All ABB load centers are rated up to 60 degree/75 degree centrigrade and is suitable for use with service entrance equipment when installed in accordance with electrical code. The TL12412R features space for 12, 1" breakers, 3 phases, a 125 A bus ampere rating, and an outdoor suitable enclosure.
ABB - Electrification · GE

TL12412R


Main lug load centers can be used as a home's main panel or sub panel depending upon your preferences. All ABB load centers are rated up to 60 degree/75 degree centrigrade and is suitable for use with service entrance equipment when installed in accordance with electrical code. The TL12412R features space for 12, 1" breakers, 3 phases, a 125 A bus ampere rating, and an outdoor suitable enclosure.

Contact for Pricing

ABB - Electrification TL18415R - Main lug load centers can be used as a home's main panel or sub panel depending upon your preferences. All ABB load centers are rated up to 60 degree/75 degree centrigrade and is suitable for use with service entrance equipment when installed in accordance with electrical code. The TL18415R features space for 18, 1" breakers, 3 phases, a 150 A bus ampere rating, and an outdoor suitable enclosure.
ABB - Electrification · GE

TL18415R


Main lug load centers can be used as a home's main panel or sub panel depending upon your preferences. All ABB load centers are rated up to 60 degree/75 degree centrigrade and is suitable for use with service entrance equipment when installed in accordance with electrical code. The TL18415R features space for 18, 1" breakers, 3 phases, a 150 A bus ampere rating, and an outdoor suitable enclosure.

Contact for Pricing

ABB - Electrification TMCB12B - Fits bottom position only B12B 125A STEEL METER SOCKET COVER-BLANK
ABB - Electrification · GE

TMCB12B


Fits bottom position only B12B 125A STEEL METER SOCKET COVER-BLANK

Contact for Pricing

ABB - Electrification TMMR6620R - MINIMOD,600A MLO,(6)200A MTRS,N3R,RINGLS
ABB - Electrification · GE

TMMR6620R


MINIMOD,600A MLO,(6)200A MTRS,N3R,RINGLS

Contact for Pricing

ABB - Electrification TMP8320R - MTR STACK,3-200A RING SKT,800A,1PH,4T
ABB - Electrification · GE

TMP8320R


MTR STACK,3-200A RING SKT,800A,1PH,4T

Contact for Pricing

ABB - Electrification TMBR3 - General Electric Service entrance. Modular meter accessories and renewal parts. 3P individual meter socket barrier kit.
ABB - Electrification · GE

TMBR3


General Electric Service entrance. Modular meter accessories and renewal parts. 3P individual meter socket barrier kit.

Contact for Pricing

Showing 4573-4584 of 18,040 results