Showing 2077-2088 of 452,163 results

Contact for Pricing

ABB - Installation Products · Ocal
STG3-G
PVC Coated Zinc Grounded Hub with Thermoplastic Insulated Throat, Pipe Size 1 Inch/27 Metric, Overall Diameter 2.00 Inch/50.80 Millimeters, Maximum Panel Thickness 0.25 Inch/6.35 Millimeters, Throat Diameter 1.00 Inch/25.40 Millimeters, Nitrile Rubber (Buna-N) Sealing Ring, Dark Gray
Contact for Pricing

PANEL DRIVE 2-QUADRANT (NON-REVERSING), Product Family: DCS800, Horsepower: 60 HP, Output Current: 104 A, Voltage: 460 VAC /500 VDC, UL TYPE OPEN (IP00), Mounting: Cabinet-mount, Circuit Breaker, Internal Line Reactor, Starter for Auxiliary Motor Cooling Fan 1.6 to 2.5A, 3-Phase Input, Frame: A-D1, Product HxWxD: 18.79 in x 12.15 in x 14.4 in, Product Weight: 88 lbs
Contact for Pricing

Hammond Power · HPS · Hazardous Application Enc. Transformers
TN2A0006KBKF
Three Phase 6kVA 480 to 400Y/231V Copper Windings 60Hertz 180°C Temperature Rise, Type 3R and Type 4
Contact for Pricing

ABB - Installation Products · STEEL CITY
LN 201
Locknut, Conduit Size 1/2 Inch, Width 1.140 Inch, Thickness 0.125 Inch, Die Cast Zinc
Contact for Pricing
Minimum Qty: 200
Multiplier: 200
*Contact for lower quantities*

ABB - Installation Products · Carlon
VC9963
Pint size standard clear PVC cement with dauber applicator.
Contact for Pricing
Minimum Qty: 24
Multiplier: 24
*Contact for lower quantities*

ABB - Installation Products · Catamount
L-14-50-0-D
Standard Cable Tie, Weather and Ultraviolet Resistant for Indoor and Outdoor Applications, Black Color Nylon 6.6, Length of 371mm (14.6 Inches) for Bundle Diameter up to 101.6mm (4 Inches), Width of 4.6mm (0.18 Inches), Tensile Strength Rating of 222 Newtons (50 Pounds), Operating Temperature of -40 Degrees Celsius (-40 F) to 85 Degrees Celsius (185 F), UL/EN/CSA62275 Type 2/21S Rated for AH-2 Plenum and as a Flexible Cable and Conduit Support, 500 Pack
Contact for Pricing
Minimum Qty: 5000
Multiplier: 5000
*Contact for lower quantities*

The National Electric Code now permits Edison-base fuses to be used only for replacements in existing installations, and then, only when there is no evidence of overfusing or tampering. All new Edison-based fuseholders must have Type S fuse adapters installed before they are placed in service. Designed to prevent installation of wrong size fuses, Type S Adapters (SAO series) screw into Edison-base fuseholders so they may accept Type S fuses. Once installed the adapters cannot be removed. To prevent shunting of open fuses or overfusing, and to reduce nuisance fuse opening, it is recommended that SAO adapters with properly rated SLO or SOO series fuses be installed in all Edison-base fuseholders.
Contact for Pricing
Minimum Qty: 4
Multiplier: 4
*Contact for lower quantities*

ABB - Electrification · GE
TEY345
UL listed HACR (Heating, Air Conditioning, Refrigeration). UL listed for HID (high intensity discharge). Thermal Magnetic Trip. Type TEY/TEYF. Noninterchangeable Trip. Bolt-on. CIRCUIT BREAKER TEY 3P 45A
Contact for Pricing

Contact for Pricing

Contact for Pricing

Contact for Pricing