All Categories

Electrical Systems and Lighting and Components and Accessories and Supplies

Electrical Equipment, Components, and Supplies

Circuit Protection Devices And Accessories

Subcategories

    Automotive Fuse

    Blade Fuses

    Cartridge Fuses

    Ceramic Fuses

    Circuit Breakers

    Circuit Interruptor

    Current Limiter

    Diazed Or Bottle Fuses

    Electronic Fuse

    Fuse Block

    Fuse Clip

    Fuse Holder

    Fuse Parts Or Accessories

    Glass Body Fuses

    Grounding Devices Or Assemblies

    High Speed Fuse

    Lightning Protection Apparatus And Accessories

    Medium Voltage Fuse

    Midget Fuses

    Miniature Circuit Breakers

    Molded Case Circuit Breakers

    Plug Fuses

    Power Fuse

    Semiconductor Fuse

    Surge Arrestor

    Surge Suppressers

    Time Delay Fuses

    Transient Protection Materials

    Vacuum Interruptor

    Voltage Regulator

Showing 2773-2784 of 3,038 results

Mersen C214523 - The NH system is classified among plug-in fuse systems and is composed of: • fuse-base, (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional. NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1×3 times nominal current for up to 10 hours. The fuse link operates at 1×5 times nominal transformer current within 2 hours. 400 Volts 200 kVA gTR NH4a series.
Mersen · Ferraz Shawmut

C214523

4086500061648


The NH system is classified among plug-in fuse systems and is composed of: • fuse-base, (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional. NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1×3 times nominal current for up to 10 hours. The fuse link operates at 1×5 times nominal transformer current within 2 hours. 400 Volts 200 kVA gTR NH4a series.

Contact for Pricing

Mersen Z214014 - The NH system is classified among plug-in fuse systems and is composed of: • fuse-base, (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional. NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1×3 times nominal current for up to 10 hours. The fuse link operates at 1×5 times nominal transformer current within 2 hours. 400 Volts 160 kVA gTR NH4a series.
Mersen · Ferraz Shawmut

Z214014

4086500061631


The NH system is classified among plug-in fuse systems and is composed of: • fuse-base, (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional. NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1×3 times nominal current for up to 10 hours. The fuse link operates at 1×5 times nominal transformer current within 2 hours. 400 Volts 160 kVA gTR NH4a series.

Contact for Pricing

Mersen L217636 - The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 690 Volts 400 amps NH2 1 pole screw terminal fuse base .
Mersen · Ferraz Shawmut

L217636

4086500052899


The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 690 Volts 400 amps NH2 1 pole screw terminal fuse base .

Contact for Pricing

Mersen D211971 - The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 690 Volts 400 amps NH2 3 pole screw terminal fuse base .
Mersen · Ferraz Shawmut

D211971

4086500034277


The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 690 Volts 400 amps NH2 3 pole screw terminal fuse base .

Contact for Pricing

Mersen W213574 - The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 500 Volts 125 amps NH00 3 pole Linocur fuse base clamp connection .
Mersen · Ferraz Shawmut

W213574

4086500038831


The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 500 Volts 125 amps NH00 3 pole Linocur fuse base clamp connection .

Contact for Pricing

Mersen Z218683 - The universal bus bar carrier is designed for bus bars with thickness of 5 mm or 10 mm retaining unchanged height of supporting edge without use of additional accessories (distance pieces). The 2-hole fixing and 4-hole fixing modular system concept provides the carrier for use in distribution units with central cover and for installation on to subplates.BS gR Series
Mersen · Ferraz Shawmut

Z218683

4086500055609


The universal bus bar carrier is designed for bus bars with thickness of 5 mm or 10 mm retaining unchanged height of supporting edge without use of additional accessories (distance pieces). The 2-hole fixing and 4-hole fixing modular system concept provides the carrier for use in distribution units with central cover and for installation on to subplates.BS gR Series

Contact for Pricing

Mersen S214537 - The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 63 amps D02 screw cap with sealable hole and testing hole .
Mersen · Ferraz Shawmut

S214537

4086500059133


The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 63 amps D02 screw cap with sealable hole and testing hole .

Contact for Pricing

Minimum Qty: 20

Multiplier: 20

*Contact for lower quantities*

Mersen H229294 - F.sw.d. NH00 160A 3P
Mersen · Ferraz Shawmut

H229294

4086500088041


F.sw.d. NH00 160A 3P

Contact for Pricing

Mersen X217738 - The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 500 Volts 32 Amps gG NH00 with puller lugs series.
Mersen · Ferraz Shawmut

X217738

8430399001241


The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 500 Volts 32 Amps gG NH00 with puller lugs series.

Contact for Pricing

Minimum Qty: 3

Multiplier: 3

*Contact for lower quantities*

Mersen J219290 - The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 500 Volts 50 Amps gG NH00 with puller lugs series.
Mersen · Ferraz Shawmut

J219290

8430399001272


The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 500 Volts 50 Amps gG NH00 with puller lugs series.

Contact for Pricing

Minimum Qty: 3

Multiplier: 3

*Contact for lower quantities*

Mersen V216724 - DISTANCIADOR NH 0
Mersen · Ferraz Shawmut

V216724

8430399005195


DISTANCIADOR NH 0

Contact for Pricing

Minimum Qty: 2

Multiplier: 2

*Contact for lower quantities*

Mersen M218787 - The Mersen M218787 is a high-quality industrial component designed for demanding applications. Engineered for reliability and durability, this product meets the rigorous standards of industrial operations. With a focus on performance and longevity, the M218787 is ideal for environments requiring precision and consistency. Trusted by professionals worldwide, Mersen delivers solutions that enhance efficiency and reduce downtime. Whether for manufacturing, energy, or automation, this component ensures optimal performance in critical systems.
Mersen · Ferraz Shawmut

M218787

8430399005218


The Mersen M218787 is a high-quality industrial component designed for demanding applications. Engineered for reliability and durability, this product meets the rigorous standards of industrial operations. With a focus on performance and longevity, the M218787 is ideal for environments requiring precision and consistency. Trusted by professionals worldwide, Mersen delivers solutions that enhance efficiency and reduce downtime. Whether for manufacturing, energy, or automation, this component ensures optimal performance in critical systems.

Contact for Pricing

Minimum Qty: 2

Multiplier: 2

*Contact for lower quantities*

Showing 2773-2784 of 3,038 results