All Categories

Electrical Systems and Lighting and Components and Accessories and Supplies

Electrical Equipment, Components, and Supplies

Circuit Protection Devices And Accessories

Subcategories

    Automotive Fuse

    Blade Fuses

    Cartridge Fuses

    Ceramic Fuses

    Circuit Breakers

    Circuit Interruptor

    Current Limiter

    Diazed Or Bottle Fuses

    Electronic Fuse

    Fuse Block

    Fuse Clip

    Fuse Holder

    Fuse Parts Or Accessories

    Glass Body Fuses

    Grounding Devices Or Assemblies

    High Speed Fuse

    Lightning Protection Apparatus And Accessories

    Medium Voltage Fuse

    Midget Fuses

    Miniature Circuit Breakers

    Molded Case Circuit Breakers

    Plug Fuses

    Power Fuse

    Semiconductor Fuse

    Surge Arrestor

    Surge Suppressers

    Time Delay Fuses

    Transient Protection Materials

    Vacuum Interruptor

    Voltage Regulator

Showing 1861-1872 of 3,038 results

Mersen V211986 - The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 100 amps D03 1 pole cover .
Mersen · Ferraz Shawmut

V211986

4086500012473


The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 100 amps D03 1 pole cover .

Contact for Pricing

Minimum Qty: 40

Multiplier: 40

*Contact for lower quantities*

Mersen B216615 - The D fuse-system is the first generation of screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D fuse range comprises the sizes NDZ, DII, DIII, DIV, DV. The range of applications for D fuse-links is the protection of cables and power lines. They limit and cut-off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 500 Volts 25 amps DII gray screw cap .
Mersen · Ferraz Shawmut

B216615

4086500014262


The D fuse-system is the first generation of screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D fuse range comprises the sizes NDZ, DII, DIII, DIV, DV. The range of applications for D fuse-links is the protection of cables and power lines. They limit and cut-off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 500 Volts 25 amps DII gray screw cap .

Contact for Pricing

Minimum Qty: 10

Multiplier: 10

*Contact for lower quantities*

Mersen S200668 - The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 20 amps D02 Gauge Ring .
Mersen · Ferraz Shawmut

S200668

4086500010943


The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 20 amps D02 Gauge Ring .

Contact for Pricing

Minimum Qty: 50

Multiplier: 50

*Contact for lower quantities*

Mersen M222122 - The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 63 amps D02 shipbuilding 1 pole fuse base .
Mersen · Ferraz Shawmut

M222122

4086500012015


The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 63 amps D02 shipbuilding 1 pole fuse base .

Contact for Pricing

Minimum Qty: 20

Multiplier: 20

*Contact for lower quantities*

Mersen V216563 - The NH system is classified among plug-in fuse systems and is composed of: • fuse-base, (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional. NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1×3 times nominal current for up to 10 hours. The fuse link operates at 1×5 times nominal transformer current within 2 hours. 400 Volts 500 kVA gTR NH4a series.
Mersen · Ferraz Shawmut

V216563

4086500032624


The NH system is classified among plug-in fuse systems and is composed of: • fuse-base, (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional. NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1×3 times nominal current for up to 10 hours. The fuse link operates at 1×5 times nominal transformer current within 2 hours. 400 Volts 500 kVA gTR NH4a series.

Contact for Pricing

Mersen F215032 - The NH system is classified among plug-in fuse systems and is composed of: • fuse-base, (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional. NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1×3 times nominal current for up to 10 hours. The fuse link operates at 1×5 times nominal transformer current within 2 hours. 400 Volts 250 kVA gTR NH4a series.
Mersen · Ferraz Shawmut

F215032

4086500032600


The NH system is classified among plug-in fuse systems and is composed of: • fuse-base, (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional. NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1×3 times nominal current for up to 10 hours. The fuse link operates at 1×5 times nominal transformer current within 2 hours. 400 Volts 250 kVA gTR NH4a series.

Contact for Pricing

Mersen K213518 - The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 63 amps D02 3 pole fuse base with cover and dual terminals .
Mersen · Ferraz Shawmut

K213518

4086500012848


The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 63 amps D02 3 pole fuse base with cover and dual terminals .

Contact for Pricing

Minimum Qty: 5

Multiplier: 5

*Contact for lower quantities*

Mersen J219681 - The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 4 amps D01 Gauge Ring .
Mersen · Ferraz Shawmut

J219681

4086500010493


The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 4 amps D01 Gauge Ring .

Contact for Pricing

Minimum Qty: 50

Multiplier: 50

*Contact for lower quantities*

Mersen E217078 - The NH system is classified among plug-in fuse systems and is composed of: • fuse-base, (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional. NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1×3 times nominal current for up to 10 hours. The fuse link operates at 1×5 times nominal transformer current within 2 hours. 400 Volts 630 kVA gTR NH4a series.
Mersen · Ferraz Shawmut

E217078

4086500032631


The NH system is classified among plug-in fuse systems and is composed of: • fuse-base, (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional. NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1×3 times nominal current for up to 10 hours. The fuse link operates at 1×5 times nominal transformer current within 2 hours. 400 Volts 630 kVA gTR NH4a series.

Contact for Pricing

Mersen K216577 - The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 2 amps D02 Gauge Ring .
Mersen · Ferraz Shawmut

K216577

4086500010646


The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 2 amps D02 Gauge Ring .

Contact for Pricing

Minimum Qty: 50

Multiplier: 50

*Contact for lower quantities*

Mersen A218109 - The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 63 amps D02 shipbuilding 3 pole fuse base .
Mersen · Ferraz Shawmut

A218109

4086500012701


The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 63 amps D02 shipbuilding 3 pole fuse base .

Contact for Pricing

Minimum Qty: 5

Multiplier: 5

*Contact for lower quantities*

Mersen R217595 - The NH system is classified among plug-in fuse systems and is composed of: • fuse-base, (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional. NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1×3 times nominal current for up to 10 hours. The fuse link operates at 1×5 times nominal transformer current within 2 hours. 400 Volts 800 kVA gTR NH4a series.
Mersen · Ferraz Shawmut

R217595

4086500032648


The NH system is classified among plug-in fuse systems and is composed of: • fuse-base, (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional. NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1×3 times nominal current for up to 10 hours. The fuse link operates at 1×5 times nominal transformer current within 2 hours. 400 Volts 800 kVA gTR NH4a series.

Contact for Pricing

Showing 1861-1872 of 3,038 results