Panduit
PUR6AS04IG-Z
Category 6A cable shall be constructed of 23 AWG copperconductors with polyolefin insulation. The copper conductors shallbe twisted in pairs and separated by a cross-divider. All four pairsshall be surrounded by an AXT barrier tape and a flame retardant(CMR) jacket. The AXT barrier tape shall minimize the cablediameter and suppress the effects of alien crosstalk while retainingU/UTP electromagnetic interference immunity.
Contact for Pricing
Minimum Qty: 4000
Multiplier: 1000
*Contact for lower quantities*

Panduit
PUP6AS04WH-GZ
Category 6A cable shall be constructed of 23 AWG copper conductorswith FEP insulation. The copper conductors shall be twisted in pairs andseparated by a cross-divider. All four pairs shall be surrounded by a nonconductiveAXT barrier tape and a flame retardant PVC (CMP) jacket.
Contact for Pricing
Minimum Qty: 9000
Multiplier: 1000
*Contact for lower quantities*

Panduit
PFP6X04OR-UGZ
Category 6A cable shall be constructed of 23 AWG copperconductors with FEP insulation. The copper conductors shall betwisted in pairs and separated by an integrated pair separator.All four pairs shall be surrounded by an overall metallic foil shieldwithin a flame retardant PVC (CMP) jacket. The TX6A ShieldedCopper Cable must be installed as part of a complete TX6AShielded Copper Cabling System to achieve 10GBASE-T certifiedperformance.
Contact for Pricing
Minimum Qty: 27000
Multiplier: 1000
*Contact for lower quantities*

Panduit
PUR6AS04YL-Z
Category 6A cable shall be constructed of 23 AWG copperconductors with polyolefin insulation. The copper conductors shallbe twisted in pairs and separated by a cross-divider. All four pairsshall be surrounded by an AXT barrier tape and a flame retardant(CMR) jacket. The AXT barrier tape shall minimize the cablediameter and suppress the effects of alien crosstalk while retainingU/UTP electromagnetic interference immunity.
Contact for Pricing
Minimum Qty: 4000
Multiplier: 1000
*Contact for lower quantities*

Panduit
PFP6C04RD-UGZ
Category 6 cable shall exceed the ANSI/TIA-568.2-E Category 6component standards. The conductors shall be 23 AWG constructionwith FEP (CMP) or PE (CMR) insulation. The copper conductors shall betwisted in pairs, separated by a cross divider, and all four pairs shall becovered with an overall foil and a low smoke, flame-retardant (CMP) orflame-retardant (CMR) PVC jacket.
Contact for Pricing
Minimum Qty: 27000
Multiplier: 1000
*Contact for lower quantities*

Panduit
PFP6C04GR-UGZ
Category 6 cable shall exceed the ANSI/TIA-568.2-E Category 6component standards. The conductors shall be 23 AWG constructionwith FEP (CMP) or PE (CMR) insulation. The copper conductors shall betwisted in pairs, separated by a cross divider, and all four pairs shall becovered with an overall foil and a low smoke, flame-retardant (CMP) orflame-retardant (CMR) PVC jacket.
Contact for Pricing
Minimum Qty: 27000
Multiplier: 1000
*Contact for lower quantities*

Panduit
IURH6X04TL-UG
Category 6A 4-pair U/UTP copper cable shall meet or exceed the ANSI/TIA-568.2-D Category 6A and ODVA EtherNet/IP standards. The solid copper conductors shall be 23 AWG with HDPE insulation. The copper conductors shall be twisted in pairs and wrapped with a foam polypropylene tape. All pairs shall then be covered with a discontinuous foil shield and an industrially rated PVC jacket which shall be oil and sunlight resistant and flame retardant to CMX/CMR for industrial Ethernet applications.
Contact for Pricing
Minimum Qty: 1000
Multiplier: 1000
*Contact for lower quantities*

Panduit
PFP6C04WH-UGZ
Category 6 cable shall exceed the ANSI/TIA-568.2-E Category 6component standards. The conductors shall be 23 AWG constructionwith FEP (CMP) or PE (CMR) insulation. The copper conductors shall betwisted in pairs, separated by a cross divider, and all four pairs shall becovered with an overall foil and a low smoke, flame-retardant (CMP) orflame-retardant (CMR) PVC jacket.
Contact for Pricing
Minimum Qty: 9000
Multiplier: 1000
*Contact for lower quantities*

Contact for Pricing

Contact for Pricing

Contact for Pricing

ABB - Electrification · ABB
2TLA020057R0020
Shielded cable without any connector. 5x0.34 mm2. Black PVC. 200 meter on spool.