All Categories

Electrical Systems and Lighting and Components and Accessories and Supplies

Electrical Equipment, Components, and Supplies

Power Conditioning Equipment

Subcategories

    Buck Boost Transformer

    Capacitor Banks

    Capacitors

    Control Power Transformer

    Current Transformer

    Distribution Power Transformers

    Electrical Or Power Regulators

    EMI/RFI Filter

    Encapsulated Transformer

    Harmonic Filter

    Harmonic Mitigation Transformer

    Inductive coupling devices

    Instrument Transformers

    Intrinsic Safety Barriers

    Isolation Transformer

    Magnetic Coils

    Motor Protection Filter

    Motor Starting Compensator

    Pad Mount Transformer

    Power Adapters Or Inverters

    Power Conditioning Accessories

    Power Distribution Units Pdus

    Power Supply Outlet Strip

    Power Supply Transformers

    Power Supply Units

    Reactors

    Signal conditioners

    Uninterruptible power supply UPS

Showing 1-8 of 8 results

Showing 1-8 of 8 results

Hitachi Energy L99M656050D - SSVT-650 Outdoor Oil-Filled Station Service Voltage Transformer, Nominal System Voltage=138kV, BIL=650kV, Operating Frequency=60Hz, Ratio=Power Winding & 700/1200:1, Accuracy=0.15 Z, Thermal Rating=50kVA, Primary Voltage=80500V, Secondary Voltage=120/240V and one metering output, Bushings=1, Bushing Creep/Strike=149.8/48.5"min, Rated Altitude=3300Ft, Bushing Material=Porcelain
Hitachi Energy

L99M656050D


SSVT-650 Outdoor Oil-Filled Station Service Voltage Transformer, Nominal System Voltage=138kV, BIL=650kV, Operating Frequency=60Hz, Ratio=Power Winding & 700/1200:1, Accuracy=0.15 Z, Thermal Rating=50kVA, Primary Voltage=80500V, Secondary Voltage=120/240V and one metering output, Bushings=1, Bushing Creep/Strike=149.8/48.5"min, Rated Altitude=3300Ft, Bushing Material=Porcelain

Contact for Pricing

Hitachi Energy P91166P100L - o?SSVT-1300 Outdoor Oil-Filled Station Service Voltage Transformer, Nominal System Voltage=345kV, BIL=1300kV, Operating Frequency=60Hz, Ratio=Power Winding Only, Accuracy=N/A, Thermal Rating=100kVA, Primary Voltage=199200V, Secondary Voltage=120/240V, Bushings=1, Bushing Creep/Strike=383.8/100.3"min, Rated Altitude=3281Ft, Bushing Material=Polymer
Hitachi Energy

P91166P100L


o?SSVT-1300 Outdoor Oil-Filled Station Service Voltage Transformer, Nominal System Voltage=345kV, BIL=1300kV, Operating Frequency=60Hz, Ratio=Power Winding Only, Accuracy=N/A, Thermal Rating=100kVA, Primary Voltage=199200V, Secondary Voltage=120/240V, Bushings=1, Bushing Creep/Strike=383.8/100.3"min, Rated Altitude=3281Ft, Bushing Material=Polymer

Contact for Pricing

Hitachi Energy L99M656100D - SSVT-650 Outdoor Oil-Filled Station Service Voltage Transformer, Nominal System Voltage=138kV, BIL=650kV, Operating Frequency=60Hz, Ratio=Power Winding & 700/1200:1, Accuracy=0.15 Z, Thermal Rating=100kVA, Primary Voltage=80500V, Secondary Voltage=120/240V and one metering output, Bushings=1, Bushing Creep/Strike=149.8/48.5"min, Rated Altitude=3300Ft, Bushing Material=Porcelain
Hitachi Energy

L99M656100D


SSVT-650 Outdoor Oil-Filled Station Service Voltage Transformer, Nominal System Voltage=138kV, BIL=650kV, Operating Frequency=60Hz, Ratio=Power Winding & 700/1200:1, Accuracy=0.15 Z, Thermal Rating=100kVA, Primary Voltage=80500V, Secondary Voltage=120/240V and one metering output, Bushings=1, Bushing Creep/Strike=149.8/48.5"min, Rated Altitude=3300Ft, Bushing Material=Porcelain

Contact for Pricing

Hitachi Energy K771102T152S - KXM-550, Outdoor Single Phase Metering Unit, Nominal System Voltage=115kV, BIL=550kV, Bushing Creep/Strike=178"/46", VT_Ratio=600/1000:1:1, VT_Primary=69000V, VT_Secondary=115/69V (2), VT_Accuracy=0.3 0,W,X,M,Y,Z,ZZ, VT_Thermal Rating=3000VA, VT_Windings_Qty=2, CT_Ratio=1500:5 SR, CT_Accuracy=0.15 B1.8 from 0.5% to 300% Inom (7.5A-4500A), CT_Rating Factor=3.0, CT_1-Second Thermal Rating=120kA rms, CT_Cores_Qty=1
Hitachi Energy

K771102T152S


KXM-550, Outdoor Single Phase Metering Unit, Nominal System Voltage=115kV, BIL=550kV, Bushing Creep/Strike=178"/46", VT_Ratio=600/1000:1:1, VT_Primary=69000V, VT_Secondary=115/69V (2), VT_Accuracy=0.3 0,W,X,M,Y,Z,ZZ, VT_Thermal Rating=3000VA, VT_Windings_Qty=2, CT_Ratio=1500:5 SR, CT_Accuracy=0.15 B1.8 from 0.5% to 300% Inom (7.5A-4500A), CT_Rating Factor=3.0, CT_1-Second Thermal Rating=120kA rms, CT_Cores_Qty=1

Contact for Pricing

Littelfuse TRAN-50VA - 120-208-240/24V 50VA TRANSFORMER LEADS
Littelfuse · Hartland Controls · HCT Series

TRAN-50VA


120-208-240/24V 50VA TRANSFORMER LEADS

Contact for Pricing

Minimum Qty: 20

Multiplier: 20

*Contact for lower quantities*

Hitachi Energy K711000TDAAYL - POF-550, Outdoor Voltage Transformer, Nominal System Voltage=115kV, BIL=550kV, Bushing Creep/Strike=138.19"/41.73"min., Ratio=600/1000:1:1, Accuracy=0.3 0,W,X,M,Y,Z,ZZ, Thermal Rating=7500VA, Primary Voltage=69000V, Secondary Voltage=115/69V (2), Bushings=1 Porcelain
Hitachi Energy

K711000TDAAYL


POF-550, Outdoor Voltage Transformer, Nominal System Voltage=115kV, BIL=550kV, Bushing Creep/Strike=138.19"/41.73"min., Ratio=600/1000:1:1, Accuracy=0.3 0,W,X,M,Y,Z,ZZ, Thermal Rating=7500VA, Primary Voltage=69000V, Secondary Voltage=115/69V (2), Bushings=1 Porcelain

Contact for Pricing

Littelfuse TRAN-75VA - 120-208-240-480/24V 75VA TRANSFORMER LDS
Littelfuse · Hartland Controls · HCT Series

TRAN-75VA


120-208-240-480/24V 75VA TRANSFORMER LDS

Contact for Pricing

Minimum Qty: 10

Multiplier: 10

*Contact for lower quantities*

Littelfuse TRAN-40VA - 120-208-240/24V 40VA TRANSFORMER LEADS
Littelfuse · Hartland Controls · HCT Series

TRAN-40VA


120-208-240/24V 40VA TRANSFORMER LEADS

Contact for Pricing

Minimum Qty: 20

Multiplier: 20

*Contact for lower quantities*

Showing 1-8 of 8 results

Showing 1-8 of 8 results