Showing 793-804 of 1,342 results

DIN Fuse base Neozed Size D02 400VAC 63A 3-Pole with touch protection DIN Rail mounting Clamp Strap
Contact for Pricing
Minimum Qty: 5
Multiplier: 5
*Contact for lower quantities*

DIN Fuse base Neozed Size D02 400VAC 63A 3-Pole without touch protection DIN Rail mounting Clamp Strap / Screw
Contact for Pricing
Minimum Qty: 5
Multiplier: 5
*Contact for lower quantities*

DIN Fuse base Neozed Size D01 400VAC 16A 1-Pole without touch protection DIN Rail mounting Clamping Yoke
Contact for Pricing
Minimum Qty: 20
Multiplier: 20
*Contact for lower quantities*

DIN Fuse base Neozed Size D02 400VAC 63A 3-Pole without touch protection DIN Rail mounting Clamp Strap
Contact for Pricing
Minimum Qty: 5
Multiplier: 5
*Contact for lower quantities*

DIN Fuse base Neozed Size D02 400VAC 63A 3-Pole without touch protection Screw mounting Clamp Strap 2 connections
Contact for Pricing
Minimum Qty: 5
Multiplier: 5
*Contact for lower quantities*

DIN Fuse base Neozed Size D02 400VAC 63A 1-Pole without touch protection DIN Rail mounting Clamp Strap
Contact for Pricing
Minimum Qty: 20
Multiplier: 20
*Contact for lower quantities*

DIN Fuse base Size DII 500VAC 500VDC 25A 1-Pole without touch protection Screw mounting
Contact for Pricing
Minimum Qty: 15
Multiplier: 15
*Contact for lower quantities*

DIN Fuse base Size DII 500VAC 500VDC 25A 1-Pole with touch protection Screw mounting
Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*

DIN Fuse base Size DII 500VAC 500VDC 25A 1-Pole with touch protection DIN Rail mounting
Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*

DIN Fuse base Size DIII 500VAC 500VDC 63A 1-Pole with touch protection Screw mounting
Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*

The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 63 amps D02 1 pole Linozed fuse base .
Contact for Pricing
Minimum Qty: 6
Multiplier: 6
*Contact for lower quantities*

Fuse Holder Modulostar® Size 14x51 IEC 690VAC 690VDC 1-Pole+N With Visual Indicator IP20
Contact for Pricing
Minimum Qty: 3
Multiplier: 3
*Contact for lower quantities*